Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog

Detalhes bibliográficos
Autor(a) principal: Moutinho da Conceição, Maria Eduarda Bastos Andrade [UNESP]
Data de Publicação: 2018
Outros Autores: dos Santos, Levi Oliveira, Sembenelli, Guilherme [UNESP], Dias Lima, Carolina Gonçalves [UNESP], de Sá Rocha, Thiago André Salvitti [UNESP], Minto, Bruno Watanabe [UNESP], Gonçalves Dias, Luis Gustavo Gosuen [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/198372
Resumo: Background: Interlocking Nail (ILN) is similar a solid intramedullary pins with screws or bolts passing through one and nail holes (locking effect). This implant mostly have been putted normograde, passing by trochanteric fossa of femur, although it is reported to be inserted through the knee, passing by fracture focus and ending close to proximal femur. It is carried out especially when there is a comminuted fracture in distal third shaft of femur. Locking plate systems work as internal fixators with some advantages compared to conventional plates. It can be used combined with intramedullary pin, and is an effective technique for increase stifeness stabilization of comminuted long-bone fractures, especially for bending. Some studies reported the use of plate-nail to increase even more the stiffness of implants, because of locking screw in plate and nail. Based on the same propose, we aim to report a case of an ILNs normograde (from distal to proximal) connected to a locking plate in highly comminuted distal diaphyseal fracture since it is rarely report in veterinary medicine orthopaedics. Case: A 5-year-old male mixed breed dog was assessed and diagnosed a fracture of the femur in the right pelvic limb. On physical examination, the dog had nonweight bearing lameness in the affected limb and, mobility of the fragments was noted following digital pressure. A comminuted fracture of the distal diaphysis of the femur was identified. A lateral approach to the shaft of the femur, the incision was extended to the stifle joint through a lateral incision because the fracture seemed to extend throughout the physis. Open but do not touch approach was performed and reduction was gotten without modified environment of fracture hematoma. A surgical drill was inserted through the access in distal extremity of the bone to open the medullary cavity of the femur. After that, an interlocking nail was inserted into the opening into the distal fragment, the fracture was reduced and the nail was inserted towards the proximal end of the bone. At the next stage the nail was fitted into the medullary canal and it was locked relative to the main fragments of the femur using locking head screws that were anchored in the load carrier of the plate. Postoperative radiographic views documented appropriate implants location and satisfactory femur fracture alignment. At 3 weeks, the patient showed functional use of the limb with partial weight bearing. Discussion: A biomechanical study comparing plate-rod and plate-nail system in gap fractures, showed that maximum load was significant different between the groups, and in plate-nail it was always heavier, it occurs because of the nail bigger diameter and screws pass through nail holes. What prove that this system is stiffer than plate-rod, so because this patient has osteopenia and thin cortical bone like showed previously, we preferred to use nail than intramedullary pin. The ILN could be introduced from proximal to distal femur (antegrade or normograde) and passing through the knee (called in medicine by retrograde, although in veterinary medicine this way is called normograte too), it depends on bone conformation. Several studies used normograde via in femur from distal to proximal, especially in distal fracture. In this case, it was used this via, by the knee, because it would promote better bone stock to insert the screws, since the nail was putted as close as possible from articular surface. In conclusion, the case reported here documented that the combination of a normograde (from distal to proximal) interlock nail with a locking plate provides a rigid fixation method, promoting satisfactory functional recovery time. Further investigations should be performed using plate-nail in vivo to give to us more precise data.
id UNSP_a463323679f267837e8e519bce443671
oai_identifier_str oai:repositorio.unesp.br:11449/198372
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dogBiological osteosynthesisCanineOrthopaedicsRetrograde nailBackground: Interlocking Nail (ILN) is similar a solid intramedullary pins with screws or bolts passing through one and nail holes (locking effect). This implant mostly have been putted normograde, passing by trochanteric fossa of femur, although it is reported to be inserted through the knee, passing by fracture focus and ending close to proximal femur. It is carried out especially when there is a comminuted fracture in distal third shaft of femur. Locking plate systems work as internal fixators with some advantages compared to conventional plates. It can be used combined with intramedullary pin, and is an effective technique for increase stifeness stabilization of comminuted long-bone fractures, especially for bending. Some studies reported the use of plate-nail to increase even more the stiffness of implants, because of locking screw in plate and nail. Based on the same propose, we aim to report a case of an ILNs normograde (from distal to proximal) connected to a locking plate in highly comminuted distal diaphyseal fracture since it is rarely report in veterinary medicine orthopaedics. Case: A 5-year-old male mixed breed dog was assessed and diagnosed a fracture of the femur in the right pelvic limb. On physical examination, the dog had nonweight bearing lameness in the affected limb and, mobility of the fragments was noted following digital pressure. A comminuted fracture of the distal diaphysis of the femur was identified. A lateral approach to the shaft of the femur, the incision was extended to the stifle joint through a lateral incision because the fracture seemed to extend throughout the physis. Open but do not touch approach was performed and reduction was gotten without modified environment of fracture hematoma. A surgical drill was inserted through the access in distal extremity of the bone to open the medullary cavity of the femur. After that, an interlocking nail was inserted into the opening into the distal fragment, the fracture was reduced and the nail was inserted towards the proximal end of the bone. At the next stage the nail was fitted into the medullary canal and it was locked relative to the main fragments of the femur using locking head screws that were anchored in the load carrier of the plate. Postoperative radiographic views documented appropriate implants location and satisfactory femur fracture alignment. At 3 weeks, the patient showed functional use of the limb with partial weight bearing. Discussion: A biomechanical study comparing plate-rod and plate-nail system in gap fractures, showed that maximum load was significant different between the groups, and in plate-nail it was always heavier, it occurs because of the nail bigger diameter and screws pass through nail holes. What prove that this system is stiffer than plate-rod, so because this patient has osteopenia and thin cortical bone like showed previously, we preferred to use nail than intramedullary pin. The ILN could be introduced from proximal to distal femur (antegrade or normograde) and passing through the knee (called in medicine by retrograde, although in veterinary medicine this way is called normograte too), it depends on bone conformation. Several studies used normograde via in femur from distal to proximal, especially in distal fracture. In this case, it was used this via, by the knee, because it would promote better bone stock to insert the screws, since the nail was putted as close as possible from articular surface. In conclusion, the case reported here documented that the combination of a normograde (from distal to proximal) interlock nail with a locking plate provides a rigid fixation method, promoting satisfactory functional recovery time. Further investigations should be performed using plate-nail in vivo to give to us more precise data.College of Agricultural Sciences and Veterinary Medicine São Paulo State University “Julio de Mesquita Filho” FCAV/UNESP, Via de acesso Paulo Donatto Castellani s/n.Metropolitan Union for Education and Culture (Unime)College of Agricultural Sciences and Veterinary Medicine São Paulo State University “Julio de Mesquita Filho” FCAV/UNESP, Via de acesso Paulo Donatto Castellani s/n.Universidade Estadual Paulista (Unesp)Metropolitan Union for Education and Culture (Unime)Moutinho da Conceição, Maria Eduarda Bastos Andrade [UNESP]dos Santos, Levi OliveiraSembenelli, Guilherme [UNESP]Dias Lima, Carolina Gonçalves [UNESP]de Sá Rocha, Thiago André Salvitti [UNESP]Minto, Bruno Watanabe [UNESP]Gonçalves Dias, Luis Gustavo Gosuen [UNESP]2020-12-12T01:11:00Z2020-12-12T01:11:00Z2018-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleActa Scientiae Veterinariae, v. 46.1679-92161678-0345http://hdl.handle.net/11449/1983722-s2.0-85077544204Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengActa Scientiae Veterinariaeinfo:eu-repo/semantics/openAccess2021-10-23T10:18:34Zoai:repositorio.unesp.br:11449/198372Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:22:38.731508Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog
title Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog
spellingShingle Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog
Moutinho da Conceição, Maria Eduarda Bastos Andrade [UNESP]
Biological osteosynthesis
Canine
Orthopaedics
Retrograde nail
title_short Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog
title_full Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog
title_fullStr Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog
title_full_unstemmed Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog
title_sort Interlocking nail combined with locking plate fixation for a distal diaphysis femur comminuted fracture in a dog
author Moutinho da Conceição, Maria Eduarda Bastos Andrade [UNESP]
author_facet Moutinho da Conceição, Maria Eduarda Bastos Andrade [UNESP]
dos Santos, Levi Oliveira
Sembenelli, Guilherme [UNESP]
Dias Lima, Carolina Gonçalves [UNESP]
de Sá Rocha, Thiago André Salvitti [UNESP]
Minto, Bruno Watanabe [UNESP]
Gonçalves Dias, Luis Gustavo Gosuen [UNESP]
author_role author
author2 dos Santos, Levi Oliveira
Sembenelli, Guilherme [UNESP]
Dias Lima, Carolina Gonçalves [UNESP]
de Sá Rocha, Thiago André Salvitti [UNESP]
Minto, Bruno Watanabe [UNESP]
Gonçalves Dias, Luis Gustavo Gosuen [UNESP]
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Metropolitan Union for Education and Culture (Unime)
dc.contributor.author.fl_str_mv Moutinho da Conceição, Maria Eduarda Bastos Andrade [UNESP]
dos Santos, Levi Oliveira
Sembenelli, Guilherme [UNESP]
Dias Lima, Carolina Gonçalves [UNESP]
de Sá Rocha, Thiago André Salvitti [UNESP]
Minto, Bruno Watanabe [UNESP]
Gonçalves Dias, Luis Gustavo Gosuen [UNESP]
dc.subject.por.fl_str_mv Biological osteosynthesis
Canine
Orthopaedics
Retrograde nail
topic Biological osteosynthesis
Canine
Orthopaedics
Retrograde nail
description Background: Interlocking Nail (ILN) is similar a solid intramedullary pins with screws or bolts passing through one and nail holes (locking effect). This implant mostly have been putted normograde, passing by trochanteric fossa of femur, although it is reported to be inserted through the knee, passing by fracture focus and ending close to proximal femur. It is carried out especially when there is a comminuted fracture in distal third shaft of femur. Locking plate systems work as internal fixators with some advantages compared to conventional plates. It can be used combined with intramedullary pin, and is an effective technique for increase stifeness stabilization of comminuted long-bone fractures, especially for bending. Some studies reported the use of plate-nail to increase even more the stiffness of implants, because of locking screw in plate and nail. Based on the same propose, we aim to report a case of an ILNs normograde (from distal to proximal) connected to a locking plate in highly comminuted distal diaphyseal fracture since it is rarely report in veterinary medicine orthopaedics. Case: A 5-year-old male mixed breed dog was assessed and diagnosed a fracture of the femur in the right pelvic limb. On physical examination, the dog had nonweight bearing lameness in the affected limb and, mobility of the fragments was noted following digital pressure. A comminuted fracture of the distal diaphysis of the femur was identified. A lateral approach to the shaft of the femur, the incision was extended to the stifle joint through a lateral incision because the fracture seemed to extend throughout the physis. Open but do not touch approach was performed and reduction was gotten without modified environment of fracture hematoma. A surgical drill was inserted through the access in distal extremity of the bone to open the medullary cavity of the femur. After that, an interlocking nail was inserted into the opening into the distal fragment, the fracture was reduced and the nail was inserted towards the proximal end of the bone. At the next stage the nail was fitted into the medullary canal and it was locked relative to the main fragments of the femur using locking head screws that were anchored in the load carrier of the plate. Postoperative radiographic views documented appropriate implants location and satisfactory femur fracture alignment. At 3 weeks, the patient showed functional use of the limb with partial weight bearing. Discussion: A biomechanical study comparing plate-rod and plate-nail system in gap fractures, showed that maximum load was significant different between the groups, and in plate-nail it was always heavier, it occurs because of the nail bigger diameter and screws pass through nail holes. What prove that this system is stiffer than plate-rod, so because this patient has osteopenia and thin cortical bone like showed previously, we preferred to use nail than intramedullary pin. The ILN could be introduced from proximal to distal femur (antegrade or normograde) and passing through the knee (called in medicine by retrograde, although in veterinary medicine this way is called normograte too), it depends on bone conformation. Several studies used normograde via in femur from distal to proximal, especially in distal fracture. In this case, it was used this via, by the knee, because it would promote better bone stock to insert the screws, since the nail was putted as close as possible from articular surface. In conclusion, the case reported here documented that the combination of a normograde (from distal to proximal) interlock nail with a locking plate provides a rigid fixation method, promoting satisfactory functional recovery time. Further investigations should be performed using plate-nail in vivo to give to us more precise data.
publishDate 2018
dc.date.none.fl_str_mv 2018-01-01
2020-12-12T01:11:00Z
2020-12-12T01:11:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv Acta Scientiae Veterinariae, v. 46.
1679-9216
1678-0345
http://hdl.handle.net/11449/198372
2-s2.0-85077544204
identifier_str_mv Acta Scientiae Veterinariae, v. 46.
1679-9216
1678-0345
2-s2.0-85077544204
url http://hdl.handle.net/11449/198372
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Scientiae Veterinariae
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128504025317376