Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.21470/1678-9741-2017-0505 http://hdl.handle.net/11449/179418 |
Resumo: | Introduction: The pacemaker implantation VDD is considered simpler, faster, less expensive and causes fewer complications compared to DDD. However, the VDD pacemaker has not been widely used in many centers, perhaps for fear of dysfunction of the sinus node and the reduction of atrial sensitivity by the pacemaker during follow-up after implantation. Objective: To compare patients with DDD and VDD pacemakers regarding the evolution of chronic atrial fibrillation (AF) and length of stay outside this postoperative arrhythmia. Methods: It was included 158 patients with dual chamber pacemakers, 48 DDD and 110 VDD. Follow-up period: between January 1, 1999 and December 31, 2015. The mean follow-up of patients with DDD was 5.35 years and the VDD, 4.74 years. The percentage of each group (DDD and VDD) which evolved to AF during follow-up was assessed. Also, it was made an actuarial study with the respective curves indicating the time free from AF for each group. Patients were classified according to the diagnosis that led to pacemaker implantation and the degree of heart failure. Results: The percentage of patients who developed AF was higher in DDD group (10.42%) than in VDD group (6.36%), but without statistical significance. Patients with DDD and VDD remained free of AF for similar period. Conclusion: Considering the results, the VDD pacemaker continues to be a good option to the DDD for routine use in cases properly indicated. |
id |
UNSP_a9f242daeae6ce99050f107d8da1e78a |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/179418 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillationArtificialAtrial fibrillationAtrioventricular blockPacemakerIntroduction: The pacemaker implantation VDD is considered simpler, faster, less expensive and causes fewer complications compared to DDD. However, the VDD pacemaker has not been widely used in many centers, perhaps for fear of dysfunction of the sinus node and the reduction of atrial sensitivity by the pacemaker during follow-up after implantation. Objective: To compare patients with DDD and VDD pacemakers regarding the evolution of chronic atrial fibrillation (AF) and length of stay outside this postoperative arrhythmia. Methods: It was included 158 patients with dual chamber pacemakers, 48 DDD and 110 VDD. Follow-up period: between January 1, 1999 and December 31, 2015. The mean follow-up of patients with DDD was 5.35 years and the VDD, 4.74 years. The percentage of each group (DDD and VDD) which evolved to AF during follow-up was assessed. Also, it was made an actuarial study with the respective curves indicating the time free from AF for each group. Patients were classified according to the diagnosis that led to pacemaker implantation and the degree of heart failure. Results: The percentage of patients who developed AF was higher in DDD group (10.42%) than in VDD group (6.36%), but without statistical significance. Patients with DDD and VDD remained free of AF for similar period. Conclusion: Considering the results, the VDD pacemaker continues to be a good option to the DDD for routine use in cases properly indicated.Faculdade de Medicina de Botucatu UnespFaculdade de Medicina de Botucatu UnespUniversidade Estadual Paulista (Unesp)de Campos, Nelson Leonardo Kerdahi Leite [UNESP]de Andrade, Rubens Ramos [UNESP]Fellicio, Marcello Laneza [UNESP]Martins, Antônio Sergio [UNESP]Garzesi, André Monti [UNESP]Garcia, Leonardo Rufino [UNESP]Takeda, Tassya Bueno [UNESP]2018-12-11T17:35:06Z2018-12-11T17:35:06Z2017-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article347-353application/pdfhttp://dx.doi.org/10.21470/1678-9741-2017-0505Brazilian Journal of Cardiovascular Surgery, v. 32, n. 5, p. 347-353, 2017.1678-97410102-7638http://hdl.handle.net/11449/17941810.21470/1678-9741-2017-0505S0102-763820170005003472-s2.0-85037364693S0102-76382017000500347.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Journal of Cardiovascular Surgery0,231info:eu-repo/semantics/openAccess2024-08-14T14:19:17Zoai:repositorio.unesp.br:11449/179418Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-14T14:19:17Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation |
title |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation |
spellingShingle |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation de Campos, Nelson Leonardo Kerdahi Leite [UNESP] Artificial Atrial fibrillation Atrioventricular block Pacemaker |
title_short |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation |
title_full |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation |
title_fullStr |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation |
title_full_unstemmed |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation |
title_sort |
Comparative study of electrical stimulation of the heart with VDD and DDD pacemakers as to the evolution to atrial fibrillation |
author |
de Campos, Nelson Leonardo Kerdahi Leite [UNESP] |
author_facet |
de Campos, Nelson Leonardo Kerdahi Leite [UNESP] de Andrade, Rubens Ramos [UNESP] Fellicio, Marcello Laneza [UNESP] Martins, Antônio Sergio [UNESP] Garzesi, André Monti [UNESP] Garcia, Leonardo Rufino [UNESP] Takeda, Tassya Bueno [UNESP] |
author_role |
author |
author2 |
de Andrade, Rubens Ramos [UNESP] Fellicio, Marcello Laneza [UNESP] Martins, Antônio Sergio [UNESP] Garzesi, André Monti [UNESP] Garcia, Leonardo Rufino [UNESP] Takeda, Tassya Bueno [UNESP] |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
de Campos, Nelson Leonardo Kerdahi Leite [UNESP] de Andrade, Rubens Ramos [UNESP] Fellicio, Marcello Laneza [UNESP] Martins, Antônio Sergio [UNESP] Garzesi, André Monti [UNESP] Garcia, Leonardo Rufino [UNESP] Takeda, Tassya Bueno [UNESP] |
dc.subject.por.fl_str_mv |
Artificial Atrial fibrillation Atrioventricular block Pacemaker |
topic |
Artificial Atrial fibrillation Atrioventricular block Pacemaker |
description |
Introduction: The pacemaker implantation VDD is considered simpler, faster, less expensive and causes fewer complications compared to DDD. However, the VDD pacemaker has not been widely used in many centers, perhaps for fear of dysfunction of the sinus node and the reduction of atrial sensitivity by the pacemaker during follow-up after implantation. Objective: To compare patients with DDD and VDD pacemakers regarding the evolution of chronic atrial fibrillation (AF) and length of stay outside this postoperative arrhythmia. Methods: It was included 158 patients with dual chamber pacemakers, 48 DDD and 110 VDD. Follow-up period: between January 1, 1999 and December 31, 2015. The mean follow-up of patients with DDD was 5.35 years and the VDD, 4.74 years. The percentage of each group (DDD and VDD) which evolved to AF during follow-up was assessed. Also, it was made an actuarial study with the respective curves indicating the time free from AF for each group. Patients were classified according to the diagnosis that led to pacemaker implantation and the degree of heart failure. Results: The percentage of patients who developed AF was higher in DDD group (10.42%) than in VDD group (6.36%), but without statistical significance. Patients with DDD and VDD remained free of AF for similar period. Conclusion: Considering the results, the VDD pacemaker continues to be a good option to the DDD for routine use in cases properly indicated. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-09-01 2018-12-11T17:35:06Z 2018-12-11T17:35:06Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.21470/1678-9741-2017-0505 Brazilian Journal of Cardiovascular Surgery, v. 32, n. 5, p. 347-353, 2017. 1678-9741 0102-7638 http://hdl.handle.net/11449/179418 10.21470/1678-9741-2017-0505 S0102-76382017000500347 2-s2.0-85037364693 S0102-76382017000500347.pdf |
url |
http://dx.doi.org/10.21470/1678-9741-2017-0505 http://hdl.handle.net/11449/179418 |
identifier_str_mv |
Brazilian Journal of Cardiovascular Surgery, v. 32, n. 5, p. 347-353, 2017. 1678-9741 0102-7638 10.21470/1678-9741-2017-0505 S0102-76382017000500347 2-s2.0-85037364693 S0102-76382017000500347.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Brazilian Journal of Cardiovascular Surgery 0,231 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
347-353 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128173432373248 |