SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/196123 |
Resumo: | Considering the operation of shunt active compensators, such as active power filters, this paper proposes possible compensation strategies by means of the recent formulation of the Conservative Power Theory (CPT). The CPT current's decomposition results in several current components, which are associated with specific load characteristics (power transfer, energy storage, unbalances and/or non linearities). These current components are used for the definition of different compensation strategies, which can be selective in terms of minimizing particular disturbing effects. In order to validate the applicability of these new compensation strategies, simulation and experimental results for three-phase four-wire systems are presented. |
id |
UNSP_af32c48949090ad6a74a8f60d06c50eb |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/196123 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITIONactive power filtersconservative power theoryselective compensationpower factorharmonic compensationreactive compensationasymmetryConsidering the operation of shunt active compensators, such as active power filters, this paper proposes possible compensation strategies by means of the recent formulation of the Conservative Power Theory (CPT). The CPT current's decomposition results in several current components, which are associated with specific load characteristics (power transfer, energy storage, unbalances and/or non linearities). These current components are used for the definition of different compensation strategies, which can be selective in terms of minimizing particular disturbing effects. In order to validate the applicability of these new compensation strategies, simulation and experimental results for three-phase four-wire systems are presented.Unesp Univ Estadual Paulista, Grp Automat & Integrating Syst, Ave Tres de Marco 511, BR-18087180 Sorocaba, SP, BrazilUnesp Univ Estadual Paulista, Grp Automat & Integrating Syst, Ave Tres de Marco 511, BR-18087180 Sorocaba, SP, BrazilIeeeUniversidade Estadual Paulista (Unesp)Paredes, H. K. M. [UNESP]Brandao, D. I. [UNESP]Terrazas, T. M. [UNESP]Marafao, F. P. [UNESP]IEEE2020-12-10T19:34:07Z2020-12-10T19:34:07Z2011-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject788-794Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 788-794, 2011.2175-8603http://hdl.handle.net/11449/196123WOS:000395311200121Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengXi Brazilian Power Electronics Conference (cobep 2011)info:eu-repo/semantics/openAccess2021-10-23T04:15:49Zoai:repositorio.unesp.br:11449/196123Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T21:08:19.865254Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION |
title |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION |
spellingShingle |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION Paredes, H. K. M. [UNESP] active power filters conservative power theory selective compensation power factor harmonic compensation reactive compensation asymmetry |
title_short |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION |
title_full |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION |
title_fullStr |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION |
title_full_unstemmed |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION |
title_sort |
SHUNT ACTIVE COMPENSATION BASED ON THE CONSERVATIVE POWER THEORY CURRENT'S DECOMPOSITION |
author |
Paredes, H. K. M. [UNESP] |
author_facet |
Paredes, H. K. M. [UNESP] Brandao, D. I. [UNESP] Terrazas, T. M. [UNESP] Marafao, F. P. [UNESP] IEEE |
author_role |
author |
author2 |
Brandao, D. I. [UNESP] Terrazas, T. M. [UNESP] Marafao, F. P. [UNESP] IEEE |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Paredes, H. K. M. [UNESP] Brandao, D. I. [UNESP] Terrazas, T. M. [UNESP] Marafao, F. P. [UNESP] IEEE |
dc.subject.por.fl_str_mv |
active power filters conservative power theory selective compensation power factor harmonic compensation reactive compensation asymmetry |
topic |
active power filters conservative power theory selective compensation power factor harmonic compensation reactive compensation asymmetry |
description |
Considering the operation of shunt active compensators, such as active power filters, this paper proposes possible compensation strategies by means of the recent formulation of the Conservative Power Theory (CPT). The CPT current's decomposition results in several current components, which are associated with specific load characteristics (power transfer, energy storage, unbalances and/or non linearities). These current components are used for the definition of different compensation strategies, which can be selective in terms of minimizing particular disturbing effects. In order to validate the applicability of these new compensation strategies, simulation and experimental results for three-phase four-wire systems are presented. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-01-01 2020-12-10T19:34:07Z 2020-12-10T19:34:07Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 788-794, 2011. 2175-8603 http://hdl.handle.net/11449/196123 WOS:000395311200121 |
identifier_str_mv |
Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 788-794, 2011. 2175-8603 WOS:000395311200121 |
url |
http://hdl.handle.net/11449/196123 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Xi Brazilian Power Electronics Conference (cobep 2011) |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
788-794 |
dc.publisher.none.fl_str_mv |
Ieee |
publisher.none.fl_str_mv |
Ieee |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129289829220352 |