Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study

Detalhes bibliográficos
Autor(a) principal: Borges, Alexandre Luiz Souto [UNESP]
Data de Publicação: 2010
Outros Autores: Borges, Alessandra Bühler [UNESP], Uemura, Eduardo Shigueyuki [UNESP], Paes-Júnior, Tarcisio José de Arruda [UNESP], Tango, Rubens Nisie [UNESP], de Araújo, José Eduardo Junho [UNESP], Kimpara, Estevão Tomomitsu [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.researchgate.net/profile/Alexandre_Borges3/publication/41124349_Evaluation_of_a_new_intraoral_paralleling_device_for_creating_guiding_planes_a_pilot_study/file/d912f50ed9f17d57d1.pdf
http://hdl.handle.net/11449/71553
Resumo: Aim: The aim of the study was to assess the accuracy of a new intraoral paralleling device for creating proximal guiding planes for removable partial dental prostheses. Methods and Materials: Thirty gypsum casts were divided into two groups in which the proximal surfaces of selected teeth were prepared using either a surveying device (Group 1) or the new ParalAB paralleling device (Group 2). In each cast guiding planes were prepared on the distal surface of the maxillary left canine (A), on the mesial and distal surfaces of the maxillary left second molar (B and C), and on the distal surface of the maxillary right canine (D). Each prepared surface formed an angle related to the occlusal plane that was measured five times and averaged by one operator using a tridimensional coordinate machine. Results: The mean guiding plane angles (± standard deviation) for the prepared surfaces were A=91.82° (±0.48°, B=90.47° (±0.47°, C=90.21° (±0.76°, and D=90.50° (±0.73°) for the dental surveyor (Group 1) and A=92.18° (±0.87°), B=90.90° (±0.85°), C=90.07° (±0.92°), and D=90.66° (±0.76°) for the ParalAB paralleling device (Group 2). A two-way ANOVA, Tukey's, and Levène's tests (at p<0.05) revealed statistically significant differences among surfaces prepared by both groups and that one surface Conclusions: The ParalAB device was able to prepare parallel surfaces and despite significant difference between groups, the ParalAB presented a small deviation from absolute parallelism and can be considered a valid method to transfer guide plans in the fabrication of removable partial dentures. Clinical Significance: The preparation of suitable guiding planes on abutment teeth during the fabrication of removable partial dentures is dependent on the ability of the operator and requires considerable chair time. When multiple teeth are involved, achieving parallelism between abutment surfaces can be technically challenging, especially in posterior regions of the mouth. The ParalAB prototype intraoral paralleling device can aid the clinician during the preparation of accurate guiding planes with a minimum degree of occlusal divergence. © 2010 Seer Publishing LLC.
id UNSP_b2d2efafe5f3155fe2c9290aedce20df
oai_identifier_str oai:repositorio.unesp.br:11449/71553
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot studyGuide planeIntraoral surveyorPath of insertionRemovable partial dentureAim: The aim of the study was to assess the accuracy of a new intraoral paralleling device for creating proximal guiding planes for removable partial dental prostheses. Methods and Materials: Thirty gypsum casts were divided into two groups in which the proximal surfaces of selected teeth were prepared using either a surveying device (Group 1) or the new ParalAB paralleling device (Group 2). In each cast guiding planes were prepared on the distal surface of the maxillary left canine (A), on the mesial and distal surfaces of the maxillary left second molar (B and C), and on the distal surface of the maxillary right canine (D). Each prepared surface formed an angle related to the occlusal plane that was measured five times and averaged by one operator using a tridimensional coordinate machine. Results: The mean guiding plane angles (± standard deviation) for the prepared surfaces were A=91.82° (±0.48°, B=90.47° (±0.47°, C=90.21° (±0.76°, and D=90.50° (±0.73°) for the dental surveyor (Group 1) and A=92.18° (±0.87°), B=90.90° (±0.85°), C=90.07° (±0.92°), and D=90.66° (±0.76°) for the ParalAB paralleling device (Group 2). A two-way ANOVA, Tukey's, and Levène's tests (at p<0.05) revealed statistically significant differences among surfaces prepared by both groups and that one surface Conclusions: The ParalAB device was able to prepare parallel surfaces and despite significant difference between groups, the ParalAB presented a small deviation from absolute parallelism and can be considered a valid method to transfer guide plans in the fabrication of removable partial dentures. Clinical Significance: The preparation of suitable guiding planes on abutment teeth during the fabrication of removable partial dentures is dependent on the ability of the operator and requires considerable chair time. When multiple teeth are involved, achieving parallelism between abutment surfaces can be technically challenging, especially in posterior regions of the mouth. The ParalAB prototype intraoral paralleling device can aid the clinician during the preparation of accurate guiding planes with a minimum degree of occlusal divergence. © 2010 Seer Publishing LLC.Department of Dental Materials and Prosthodontics School of Dentistry of São José dos Campos São Paulo State University-UNES, São José dos Campos, São PauloDepartment of Restorative Dentistry School of Dentistry of São José dos Campos São Paulo State University-UNESP, São José dos Campos, São PauloDepartment of Dental Materials and Prosthodontics School of Dentistry of São José dos Campos São Paulo State University-UNES, São José dos Campos, São PauloDepartment of Restorative Dentistry School of Dentistry of São José dos Campos São Paulo State University-UNESP, São José dos Campos, São PauloUniversidade Estadual Paulista (Unesp)Borges, Alexandre Luiz Souto [UNESP]Borges, Alessandra Bühler [UNESP]Uemura, Eduardo Shigueyuki [UNESP]Paes-Júnior, Tarcisio José de Arruda [UNESP]Tango, Rubens Nisie [UNESP]de Araújo, José Eduardo Junho [UNESP]Kimpara, Estevão Tomomitsu [UNESP]2014-05-27T11:24:37Z2014-05-27T11:24:37Z2010-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article65-72application/pdfhttp://www.researchgate.net/profile/Alexandre_Borges3/publication/41124349_Evaluation_of_a_new_intraoral_paralleling_device_for_creating_guiding_planes_a_pilot_study/file/d912f50ed9f17d57d1.pdfJournal of Contemporary Dental Practice, v. 11, n. 1, p. 65-72, 2010.1526-3711http://hdl.handle.net/11449/715532-s2.0-800534235342-s2.0-779504876002-s2.0-80053423534.pdf604345930417601569604700530379051843509097437262913871668044060309679163886657540000-0002-5707-75650000-0003-0586-46440000-0003-0946-1826Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Contemporary Dental Practice0,263info:eu-repo/semantics/openAccess2023-12-18T06:16:59Zoai:repositorio.unesp.br:11449/71553Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-12-18T06:16:59Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study
title Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study
spellingShingle Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study
Borges, Alexandre Luiz Souto [UNESP]
Guide plane
Intraoral surveyor
Path of insertion
Removable partial denture
title_short Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study
title_full Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study
title_fullStr Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study
title_full_unstemmed Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study
title_sort Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study
author Borges, Alexandre Luiz Souto [UNESP]
author_facet Borges, Alexandre Luiz Souto [UNESP]
Borges, Alessandra Bühler [UNESP]
Uemura, Eduardo Shigueyuki [UNESP]
Paes-Júnior, Tarcisio José de Arruda [UNESP]
Tango, Rubens Nisie [UNESP]
de Araújo, José Eduardo Junho [UNESP]
Kimpara, Estevão Tomomitsu [UNESP]
author_role author
author2 Borges, Alessandra Bühler [UNESP]
Uemura, Eduardo Shigueyuki [UNESP]
Paes-Júnior, Tarcisio José de Arruda [UNESP]
Tango, Rubens Nisie [UNESP]
de Araújo, José Eduardo Junho [UNESP]
Kimpara, Estevão Tomomitsu [UNESP]
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Borges, Alexandre Luiz Souto [UNESP]
Borges, Alessandra Bühler [UNESP]
Uemura, Eduardo Shigueyuki [UNESP]
Paes-Júnior, Tarcisio José de Arruda [UNESP]
Tango, Rubens Nisie [UNESP]
de Araújo, José Eduardo Junho [UNESP]
Kimpara, Estevão Tomomitsu [UNESP]
dc.subject.por.fl_str_mv Guide plane
Intraoral surveyor
Path of insertion
Removable partial denture
topic Guide plane
Intraoral surveyor
Path of insertion
Removable partial denture
description Aim: The aim of the study was to assess the accuracy of a new intraoral paralleling device for creating proximal guiding planes for removable partial dental prostheses. Methods and Materials: Thirty gypsum casts were divided into two groups in which the proximal surfaces of selected teeth were prepared using either a surveying device (Group 1) or the new ParalAB paralleling device (Group 2). In each cast guiding planes were prepared on the distal surface of the maxillary left canine (A), on the mesial and distal surfaces of the maxillary left second molar (B and C), and on the distal surface of the maxillary right canine (D). Each prepared surface formed an angle related to the occlusal plane that was measured five times and averaged by one operator using a tridimensional coordinate machine. Results: The mean guiding plane angles (± standard deviation) for the prepared surfaces were A=91.82° (±0.48°, B=90.47° (±0.47°, C=90.21° (±0.76°, and D=90.50° (±0.73°) for the dental surveyor (Group 1) and A=92.18° (±0.87°), B=90.90° (±0.85°), C=90.07° (±0.92°), and D=90.66° (±0.76°) for the ParalAB paralleling device (Group 2). A two-way ANOVA, Tukey's, and Levène's tests (at p<0.05) revealed statistically significant differences among surfaces prepared by both groups and that one surface Conclusions: The ParalAB device was able to prepare parallel surfaces and despite significant difference between groups, the ParalAB presented a small deviation from absolute parallelism and can be considered a valid method to transfer guide plans in the fabrication of removable partial dentures. Clinical Significance: The preparation of suitable guiding planes on abutment teeth during the fabrication of removable partial dentures is dependent on the ability of the operator and requires considerable chair time. When multiple teeth are involved, achieving parallelism between abutment surfaces can be technically challenging, especially in posterior regions of the mouth. The ParalAB prototype intraoral paralleling device can aid the clinician during the preparation of accurate guiding planes with a minimum degree of occlusal divergence. © 2010 Seer Publishing LLC.
publishDate 2010
dc.date.none.fl_str_mv 2010-01-01
2014-05-27T11:24:37Z
2014-05-27T11:24:37Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.researchgate.net/profile/Alexandre_Borges3/publication/41124349_Evaluation_of_a_new_intraoral_paralleling_device_for_creating_guiding_planes_a_pilot_study/file/d912f50ed9f17d57d1.pdf
Journal of Contemporary Dental Practice, v. 11, n. 1, p. 65-72, 2010.
1526-3711
http://hdl.handle.net/11449/71553
2-s2.0-80053423534
2-s2.0-77950487600
2-s2.0-80053423534.pdf
6043459304176015
6960470053037905
1843509097437262
9138716680440603
0967916388665754
0000-0002-5707-7565
0000-0003-0586-4644
0000-0003-0946-1826
url http://www.researchgate.net/profile/Alexandre_Borges3/publication/41124349_Evaluation_of_a_new_intraoral_paralleling_device_for_creating_guiding_planes_a_pilot_study/file/d912f50ed9f17d57d1.pdf
http://hdl.handle.net/11449/71553
identifier_str_mv Journal of Contemporary Dental Practice, v. 11, n. 1, p. 65-72, 2010.
1526-3711
2-s2.0-80053423534
2-s2.0-77950487600
2-s2.0-80053423534.pdf
6043459304176015
6960470053037905
1843509097437262
9138716680440603
0967916388665754
0000-0002-5707-7565
0000-0003-0586-4644
0000-0003-0946-1826
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Contemporary Dental Practice
0,263
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 65-72
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799965326092271616