Development of a low cost force platform for biomechanical parameters analysis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/2446-4740.01217 http://hdl.handle.net/11449/212255 |
Resumo: | AbstractIntroduction: The maintenance of balance and body orientation during standing is essential to perform different activities. One of the devices used to measure balance them is the force platform. This device measures the ground reaction force (GRF) and displacement of the center of pressure (COP), both biomechanical parameters involved in human motion. This article proposes a new design for non-commercial low-cost force platforms for scientific research purposes. Methods for calibration and validation are also described. |
id |
UNSP_b456f9ace3b3546429c738e4e780bdcd |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/212255 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Development of a low cost force platform for biomechanical parameters analysisForce platformBiomechanical parametersLow-cost developmentGround-reaction forceCOP displacementAbstractIntroduction: The maintenance of balance and body orientation during standing is essential to perform different activities. One of the devices used to measure balance them is the force platform. This device measures the ground reaction force (GRF) and displacement of the center of pressure (COP), both biomechanical parameters involved in human motion. This article proposes a new design for non-commercial low-cost force platforms for scientific research purposes. Methods for calibration and validation are also described.São Paulo State University, Faculty of Engineering of GuaratinguetáFederal University of Rio de Janeiro, Biomedical Engineering ProgramRio de Janeiro State University, Faculty of TechnologySão Paulo State University, Faculty of Engineering of GuaratinguetáSociedade Brasileira de Engenharia BiomédicaUniversidade Estadual Paulista (Unesp)Federal University of Rio de JaneiroRio de Janeiro State UniversitySilva, Marcelo Guimarães [UNESP]Moreira, Pedro Vieira SarmetRocha, Henrique Martins2021-07-14T10:37:04Z2021-07-14T10:37:04Z2017-09-12info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article259-268application/pdfhttp://dx.doi.org/10.1590/2446-4740.01217Research on Biomedical Engineering. Sociedade Brasileira de Engenharia Biomédica, v. 33, n. 3, p. 259-268, 2017.2446-47322446-4740http://hdl.handle.net/11449/21225510.1590/2446-4740.01217S2446-47402017000300259S2446-47402017000300259.pdfSciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengResearch on Biomedical Engineeringinfo:eu-repo/semantics/openAccess2024-01-22T06:23:47Zoai:repositorio.unesp.br:11449/212255Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-01-22T06:23:47Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Development of a low cost force platform for biomechanical parameters analysis |
title |
Development of a low cost force platform for biomechanical parameters analysis |
spellingShingle |
Development of a low cost force platform for biomechanical parameters analysis Silva, Marcelo Guimarães [UNESP] Force platform Biomechanical parameters Low-cost development Ground-reaction force COP displacement |
title_short |
Development of a low cost force platform for biomechanical parameters analysis |
title_full |
Development of a low cost force platform for biomechanical parameters analysis |
title_fullStr |
Development of a low cost force platform for biomechanical parameters analysis |
title_full_unstemmed |
Development of a low cost force platform for biomechanical parameters analysis |
title_sort |
Development of a low cost force platform for biomechanical parameters analysis |
author |
Silva, Marcelo Guimarães [UNESP] |
author_facet |
Silva, Marcelo Guimarães [UNESP] Moreira, Pedro Vieira Sarmet Rocha, Henrique Martins |
author_role |
author |
author2 |
Moreira, Pedro Vieira Sarmet Rocha, Henrique Martins |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Federal University of Rio de Janeiro Rio de Janeiro State University |
dc.contributor.author.fl_str_mv |
Silva, Marcelo Guimarães [UNESP] Moreira, Pedro Vieira Sarmet Rocha, Henrique Martins |
dc.subject.por.fl_str_mv |
Force platform Biomechanical parameters Low-cost development Ground-reaction force COP displacement |
topic |
Force platform Biomechanical parameters Low-cost development Ground-reaction force COP displacement |
description |
AbstractIntroduction: The maintenance of balance and body orientation during standing is essential to perform different activities. One of the devices used to measure balance them is the force platform. This device measures the ground reaction force (GRF) and displacement of the center of pressure (COP), both biomechanical parameters involved in human motion. This article proposes a new design for non-commercial low-cost force platforms for scientific research purposes. Methods for calibration and validation are also described. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-09-12 2021-07-14T10:37:04Z 2021-07-14T10:37:04Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/2446-4740.01217 Research on Biomedical Engineering. Sociedade Brasileira de Engenharia Biomédica, v. 33, n. 3, p. 259-268, 2017. 2446-4732 2446-4740 http://hdl.handle.net/11449/212255 10.1590/2446-4740.01217 S2446-47402017000300259 S2446-47402017000300259.pdf |
url |
http://dx.doi.org/10.1590/2446-4740.01217 http://hdl.handle.net/11449/212255 |
identifier_str_mv |
Research on Biomedical Engineering. Sociedade Brasileira de Engenharia Biomédica, v. 33, n. 3, p. 259-268, 2017. 2446-4732 2446-4740 10.1590/2446-4740.01217 S2446-47402017000300259 S2446-47402017000300259.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Research on Biomedical Engineering |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
259-268 application/pdf |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Engenharia Biomédica |
publisher.none.fl_str_mv |
Sociedade Brasileira de Engenharia Biomédica |
dc.source.none.fl_str_mv |
SciELO reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1803047397971984384 |