Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil

Detalhes bibliográficos
Autor(a) principal: Carvalho, Fernando K.
Data de Publicação: 2016
Outros Autores: Antuniassi, Ulisses R. [UNESP], Chechetto, Rodolfo G., Mota, Alisson A.B., Kruger, Greg R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/1809-4430-Eng.Agric.v36n6p1118-1125/2016
http://hdl.handle.net/11449/169252
Resumo: The effect of blade angle on droplet size spectrum of five rotary cage atomizers and one rotary disc atomizer used in Brazil was evaluated in a high speed wind tunnel, with an air speed of 180 km h-1. This study included the characterization of the droplet size spectrum, via laser diffraction instrument, generated by three blades angles, of 45, 60 and 75 degrees. The spray solution was composed of Picoxystrobin + Cyproconazole fungicide (SC), at 20 mL c.p. L-1, and at a flow rate of 6 L min-1. As the angle decreased from 75 to 45 degrees, the rotational speed of the atomizers increased and the volume median diameter (VMD) decreased. However, increasing the rotational speed also increased the percentage of droplets smaller than 100 μm (% < 100 μm). At the blade angles of 45 and 60 degrees the atomizers showed that %<100 μm was higher than 20% and VMD was smaller than 198 μm. The disc type atomizer resulted in the lower values of relative span (RS). The use of 75 degrees blade angle produced the highest values of VMD and the lowest values of %<100 μm; these parameters were also affected by atomizer model and brand.
id UNSP_b6c1e6d54d9bbc71222845d64a5b1232
oai_identifier_str oai:repositorio.unesp.br:11449/169252
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Blade angle effect on droplet size spectrum of rotary atomizers used in BrazilApplication technologyAtomizationPesticidesSpray driftThe effect of blade angle on droplet size spectrum of five rotary cage atomizers and one rotary disc atomizer used in Brazil was evaluated in a high speed wind tunnel, with an air speed of 180 km h-1. This study included the characterization of the droplet size spectrum, via laser diffraction instrument, generated by three blades angles, of 45, 60 and 75 degrees. The spray solution was composed of Picoxystrobin + Cyproconazole fungicide (SC), at 20 mL c.p. L-1, and at a flow rate of 6 L min-1. As the angle decreased from 75 to 45 degrees, the rotational speed of the atomizers increased and the volume median diameter (VMD) decreased. However, increasing the rotational speed also increased the percentage of droplets smaller than 100 μm (% < 100 μm). At the blade angles of 45 and 60 degrees the atomizers showed that %<100 μm was higher than 20% and VMD was smaller than 198 μm. The disc type atomizer resulted in the lower values of relative span (RS). The use of 75 degrees blade angle produced the highest values of VMD and the lowest values of %<100 μm; these parameters were also affected by atomizer model and brand.AgroEfetivaUniversidade Estadual Paulista Faculdade de Ciências Agronômicas (UNESP/FCA)University of Nebraska-Lincoln West Central Research and Extension CenterUniversidade Estadual Paulista Faculdade de Ciências Agronômicas (UNESP/FCA)AgroEfetivaUniversidade Estadual Paulista (Unesp)West Central Research and Extension CenterCarvalho, Fernando K.Antuniassi, Ulisses R. [UNESP]Chechetto, Rodolfo G.Mota, Alisson A.B.Kruger, Greg R.2018-12-11T16:45:05Z2018-12-11T16:45:05Z2016-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1118-1125application/pdfhttp://dx.doi.org/10.1590/1809-4430-Eng.Agric.v36n6p1118-1125/2016Engenharia Agricola, v. 36, n. 6, p. 1118-1125, 2016.1808-43890100-6916http://hdl.handle.net/11449/16925210.1590/1809-4430-Eng.Agric.v36n6p1118-1125/2016S0100-691620160006011182-s2.0-85006783252S0100-69162016000601118.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengEngenharia Agricola0,305info:eu-repo/semantics/openAccess2023-10-18T06:10:14Zoai:repositorio.unesp.br:11449/169252Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-10-18T06:10:14Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil
title Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil
spellingShingle Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil
Carvalho, Fernando K.
Application technology
Atomization
Pesticides
Spray drift
title_short Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil
title_full Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil
title_fullStr Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil
title_full_unstemmed Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil
title_sort Blade angle effect on droplet size spectrum of rotary atomizers used in Brazil
author Carvalho, Fernando K.
author_facet Carvalho, Fernando K.
Antuniassi, Ulisses R. [UNESP]
Chechetto, Rodolfo G.
Mota, Alisson A.B.
Kruger, Greg R.
author_role author
author2 Antuniassi, Ulisses R. [UNESP]
Chechetto, Rodolfo G.
Mota, Alisson A.B.
Kruger, Greg R.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv AgroEfetiva
Universidade Estadual Paulista (Unesp)
West Central Research and Extension Center
dc.contributor.author.fl_str_mv Carvalho, Fernando K.
Antuniassi, Ulisses R. [UNESP]
Chechetto, Rodolfo G.
Mota, Alisson A.B.
Kruger, Greg R.
dc.subject.por.fl_str_mv Application technology
Atomization
Pesticides
Spray drift
topic Application technology
Atomization
Pesticides
Spray drift
description The effect of blade angle on droplet size spectrum of five rotary cage atomizers and one rotary disc atomizer used in Brazil was evaluated in a high speed wind tunnel, with an air speed of 180 km h-1. This study included the characterization of the droplet size spectrum, via laser diffraction instrument, generated by three blades angles, of 45, 60 and 75 degrees. The spray solution was composed of Picoxystrobin + Cyproconazole fungicide (SC), at 20 mL c.p. L-1, and at a flow rate of 6 L min-1. As the angle decreased from 75 to 45 degrees, the rotational speed of the atomizers increased and the volume median diameter (VMD) decreased. However, increasing the rotational speed also increased the percentage of droplets smaller than 100 μm (% < 100 μm). At the blade angles of 45 and 60 degrees the atomizers showed that %<100 μm was higher than 20% and VMD was smaller than 198 μm. The disc type atomizer resulted in the lower values of relative span (RS). The use of 75 degrees blade angle produced the highest values of VMD and the lowest values of %<100 μm; these parameters were also affected by atomizer model and brand.
publishDate 2016
dc.date.none.fl_str_mv 2016-01-01
2018-12-11T16:45:05Z
2018-12-11T16:45:05Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/1809-4430-Eng.Agric.v36n6p1118-1125/2016
Engenharia Agricola, v. 36, n. 6, p. 1118-1125, 2016.
1808-4389
0100-6916
http://hdl.handle.net/11449/169252
10.1590/1809-4430-Eng.Agric.v36n6p1118-1125/2016
S0100-69162016000601118
2-s2.0-85006783252
S0100-69162016000601118.pdf
url http://dx.doi.org/10.1590/1809-4430-Eng.Agric.v36n6p1118-1125/2016
http://hdl.handle.net/11449/169252
identifier_str_mv Engenharia Agricola, v. 36, n. 6, p. 1118-1125, 2016.
1808-4389
0100-6916
10.1590/1809-4430-Eng.Agric.v36n6p1118-1125/2016
S0100-69162016000601118
2-s2.0-85006783252
S0100-69162016000601118.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Engenharia Agricola
0,305
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1118-1125
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1797789436520431616