Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.21664/2238-8869.2020v9i2.p128-141 http://hdl.handle.net/11449/205307 |
Resumo: | Considering the damage resulting from in natura disposal of waste in soil or water bodies, we installed an alternative system of domestic effluent treatment consisting of a septic tank combined with an anaerobic filter, including a root zone. System efficiency was evaluated based on physical, chemical, and biological analyses, in addition to ecotoxicological tests (toxicity tests with Ceriodaphnia dubia). Conductivity values decreased from 3380 to 561 µS cm-1 (83.4%) after treatment. Average organic matter removal efficiency was 88.75% and there was a significant decrease in BOD. Phosphorus removal percentage was 97.68%, while nitrogen removal percentage was 94.7%. Toxicity tests determined an LC50 = 1.70% for the raw effluent and an LC50 = 16.63% for the treated effluent. The system achieved good efficiency in reducing all analyzed parameters. The use of a plastic residue as a filter element in the anaerobic filter proved to be feasible. |
id |
UNSP_b81f837181d9aaa0367ead8c72499ea1 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/205307 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zoneAnaerobic filterConduitsRoot zoneSeptic tankConsidering the damage resulting from in natura disposal of waste in soil or water bodies, we installed an alternative system of domestic effluent treatment consisting of a septic tank combined with an anaerobic filter, including a root zone. System efficiency was evaluated based on physical, chemical, and biological analyses, in addition to ecotoxicological tests (toxicity tests with Ceriodaphnia dubia). Conductivity values decreased from 3380 to 561 µS cm-1 (83.4%) after treatment. Average organic matter removal efficiency was 88.75% and there was a significant decrease in BOD. Phosphorus removal percentage was 97.68%, while nitrogen removal percentage was 94.7%. Toxicity tests determined an LC50 = 1.70% for the raw effluent and an LC50 = 16.63% for the treated effluent. The system achieved good efficiency in reducing all analyzed parameters. The use of a plastic residue as a filter element in the anaerobic filter proved to be feasible.UNESP Instituto de Ciência e TecnologiaSecretaria Municipal de Meio Ambiente de UbatubaDepartamento de Engenharia Ambiental UNESP Instituto de Ciência e TecnologiaUNESP Instituto de Ciência e TecnologiaDepartamento de Engenharia Ambiental UNESP Instituto de Ciência e TecnologiaUniversidade Estadual Paulista (Unesp)Secretaria Municipal de Meio Ambiente de UbatubaLira, Vivian Silva [UNESP]Freire, Alice GabrielaFracácio, Renata [UNESP]Morais, Leandro Cardoso [UNESP]2021-06-25T10:13:12Z2021-06-25T10:13:12Z2020-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article128-141http://dx.doi.org/10.21664/2238-8869.2020v9i2.p128-141Fronteiras, v. 9, n. 2, p. 128-141, 2020.2238-8869http://hdl.handle.net/11449/20530710.21664/2238-8869.2020v9i2.p128-1412-s2.0-85092579331Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengFronteirasinfo:eu-repo/semantics/openAccess2021-10-23T12:31:33Zoai:repositorio.unesp.br:11449/205307Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:55:59.177Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone |
title |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone |
spellingShingle |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone Lira, Vivian Silva [UNESP] Anaerobic filter Conduits Root zone Septic tank |
title_short |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone |
title_full |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone |
title_fullStr |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone |
title_full_unstemmed |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone |
title_sort |
Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone |
author |
Lira, Vivian Silva [UNESP] |
author_facet |
Lira, Vivian Silva [UNESP] Freire, Alice Gabriela Fracácio, Renata [UNESP] Morais, Leandro Cardoso [UNESP] |
author_role |
author |
author2 |
Freire, Alice Gabriela Fracácio, Renata [UNESP] Morais, Leandro Cardoso [UNESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Secretaria Municipal de Meio Ambiente de Ubatuba |
dc.contributor.author.fl_str_mv |
Lira, Vivian Silva [UNESP] Freire, Alice Gabriela Fracácio, Renata [UNESP] Morais, Leandro Cardoso [UNESP] |
dc.subject.por.fl_str_mv |
Anaerobic filter Conduits Root zone Septic tank |
topic |
Anaerobic filter Conduits Root zone Septic tank |
description |
Considering the damage resulting from in natura disposal of waste in soil or water bodies, we installed an alternative system of domestic effluent treatment consisting of a septic tank combined with an anaerobic filter, including a root zone. System efficiency was evaluated based on physical, chemical, and biological analyses, in addition to ecotoxicological tests (toxicity tests with Ceriodaphnia dubia). Conductivity values decreased from 3380 to 561 µS cm-1 (83.4%) after treatment. Average organic matter removal efficiency was 88.75% and there was a significant decrease in BOD. Phosphorus removal percentage was 97.68%, while nitrogen removal percentage was 94.7%. Toxicity tests determined an LC50 = 1.70% for the raw effluent and an LC50 = 16.63% for the treated effluent. The system achieved good efficiency in reducing all analyzed parameters. The use of a plastic residue as a filter element in the anaerobic filter proved to be feasible. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-01-01 2021-06-25T10:13:12Z 2021-06-25T10:13:12Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.21664/2238-8869.2020v9i2.p128-141 Fronteiras, v. 9, n. 2, p. 128-141, 2020. 2238-8869 http://hdl.handle.net/11449/205307 10.21664/2238-8869.2020v9i2.p128-141 2-s2.0-85092579331 |
url |
http://dx.doi.org/10.21664/2238-8869.2020v9i2.p128-141 http://hdl.handle.net/11449/205307 |
identifier_str_mv |
Fronteiras, v. 9, n. 2, p. 128-141, 2020. 2238-8869 10.21664/2238-8869.2020v9i2.p128-141 2-s2.0-85092579331 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Fronteiras |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
128-141 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128876694470656 |