Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone

Detalhes bibliográficos
Autor(a) principal: Lira, Vivian Silva [UNESP]
Data de Publicação: 2020
Outros Autores: Freire, Alice Gabriela, Fracácio, Renata [UNESP], Morais, Leandro Cardoso [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.21664/2238-8869.2020v9i2.p128-141
http://hdl.handle.net/11449/205307
Resumo: Considering the damage resulting from in natura disposal of waste in soil or water bodies, we installed an alternative system of domestic effluent treatment consisting of a septic tank combined with an anaerobic filter, including a root zone. System efficiency was evaluated based on physical, chemical, and biological analyses, in addition to ecotoxicological tests (toxicity tests with Ceriodaphnia dubia). Conductivity values decreased from 3380 to 561 µS cm-1 (83.4%) after treatment. Average organic matter removal efficiency was 88.75% and there was a significant decrease in BOD. Phosphorus removal percentage was 97.68%, while nitrogen removal percentage was 94.7%. Toxicity tests determined an LC50 = 1.70% for the raw effluent and an LC50 = 16.63% for the treated effluent. The system achieved good efficiency in reducing all analyzed parameters. The use of a plastic residue as a filter element in the anaerobic filter proved to be feasible.
id UNSP_b81f837181d9aaa0367ead8c72499ea1
oai_identifier_str oai:repositorio.unesp.br:11449/205307
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zoneAnaerobic filterConduitsRoot zoneSeptic tankConsidering the damage resulting from in natura disposal of waste in soil or water bodies, we installed an alternative system of domestic effluent treatment consisting of a septic tank combined with an anaerobic filter, including a root zone. System efficiency was evaluated based on physical, chemical, and biological analyses, in addition to ecotoxicological tests (toxicity tests with Ceriodaphnia dubia). Conductivity values decreased from 3380 to 561 µS cm-1 (83.4%) after treatment. Average organic matter removal efficiency was 88.75% and there was a significant decrease in BOD. Phosphorus removal percentage was 97.68%, while nitrogen removal percentage was 94.7%. Toxicity tests determined an LC50 = 1.70% for the raw effluent and an LC50 = 16.63% for the treated effluent. The system achieved good efficiency in reducing all analyzed parameters. The use of a plastic residue as a filter element in the anaerobic filter proved to be feasible.UNESP Instituto de Ciência e TecnologiaSecretaria Municipal de Meio Ambiente de UbatubaDepartamento de Engenharia Ambiental UNESP Instituto de Ciência e TecnologiaUNESP Instituto de Ciência e TecnologiaDepartamento de Engenharia Ambiental UNESP Instituto de Ciência e TecnologiaUniversidade Estadual Paulista (Unesp)Secretaria Municipal de Meio Ambiente de UbatubaLira, Vivian Silva [UNESP]Freire, Alice GabrielaFracácio, Renata [UNESP]Morais, Leandro Cardoso [UNESP]2021-06-25T10:13:12Z2021-06-25T10:13:12Z2020-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article128-141http://dx.doi.org/10.21664/2238-8869.2020v9i2.p128-141Fronteiras, v. 9, n. 2, p. 128-141, 2020.2238-8869http://hdl.handle.net/11449/20530710.21664/2238-8869.2020v9i2.p128-1412-s2.0-85092579331Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengFronteirasinfo:eu-repo/semantics/openAccess2021-10-23T12:31:33Zoai:repositorio.unesp.br:11449/205307Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:55:59.177Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
title Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
spellingShingle Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
Lira, Vivian Silva [UNESP]
Anaerobic filter
Conduits
Root zone
Septic tank
title_short Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
title_full Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
title_fullStr Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
title_full_unstemmed Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
title_sort Evaluation of the efficiency of a septic tank combined with anaerobic filter, filled with plastic residue, including a root zone
author Lira, Vivian Silva [UNESP]
author_facet Lira, Vivian Silva [UNESP]
Freire, Alice Gabriela
Fracácio, Renata [UNESP]
Morais, Leandro Cardoso [UNESP]
author_role author
author2 Freire, Alice Gabriela
Fracácio, Renata [UNESP]
Morais, Leandro Cardoso [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Secretaria Municipal de Meio Ambiente de Ubatuba
dc.contributor.author.fl_str_mv Lira, Vivian Silva [UNESP]
Freire, Alice Gabriela
Fracácio, Renata [UNESP]
Morais, Leandro Cardoso [UNESP]
dc.subject.por.fl_str_mv Anaerobic filter
Conduits
Root zone
Septic tank
topic Anaerobic filter
Conduits
Root zone
Septic tank
description Considering the damage resulting from in natura disposal of waste in soil or water bodies, we installed an alternative system of domestic effluent treatment consisting of a septic tank combined with an anaerobic filter, including a root zone. System efficiency was evaluated based on physical, chemical, and biological analyses, in addition to ecotoxicological tests (toxicity tests with Ceriodaphnia dubia). Conductivity values decreased from 3380 to 561 µS cm-1 (83.4%) after treatment. Average organic matter removal efficiency was 88.75% and there was a significant decrease in BOD. Phosphorus removal percentage was 97.68%, while nitrogen removal percentage was 94.7%. Toxicity tests determined an LC50 = 1.70% for the raw effluent and an LC50 = 16.63% for the treated effluent. The system achieved good efficiency in reducing all analyzed parameters. The use of a plastic residue as a filter element in the anaerobic filter proved to be feasible.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-01
2021-06-25T10:13:12Z
2021-06-25T10:13:12Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.21664/2238-8869.2020v9i2.p128-141
Fronteiras, v. 9, n. 2, p. 128-141, 2020.
2238-8869
http://hdl.handle.net/11449/205307
10.21664/2238-8869.2020v9i2.p128-141
2-s2.0-85092579331
url http://dx.doi.org/10.21664/2238-8869.2020v9i2.p128-141
http://hdl.handle.net/11449/205307
identifier_str_mv Fronteiras, v. 9, n. 2, p. 128-141, 2020.
2238-8869
10.21664/2238-8869.2020v9i2.p128-141
2-s2.0-85092579331
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Fronteiras
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 128-141
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128876694470656