Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix

Detalhes bibliográficos
Autor(a) principal: de Araújo, Danyelle Medeiros
Data de Publicação: 2022
Outros Autores: Dos Santos, Elisama V. [UNESP], Martínez-Huitle, Carlos A. [UNESP], De Battisti, Achille
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.3390/app12020699
http://hdl.handle.net/11449/223242
Resumo: Hydroxychloroquine (HCQ) has been extensively consumed due to the Coronavirus (COVID-19) pandemic. Therefore, it is increasingly found in different water matrices. For this reason, the concentration of HCQ in water should be monitored and the treatment of contaminated water matrices with HCQ is a key issue to overcome immediately. Thus, in this study, the development of technologies and smart water solutions to reach the Sustainable Development Goal 6 (SDG6) is the main objective. To do that, the integration of electrochemical technologies for their environmental application on HCQ detection, quantification and degradation was performed. Firstly, an electrochemical cork-graphite sensor was prepared to identify/quantify HCQ in river water matrices by differential pulse voltammetric (DPV) method. Subsequently, an HCQ-polluted river water sample was electrochemically treated with BDD electrode by applying 15, 30 and 45 mA cm−2. The HCQ decay and organic matter removal was monitored by DPV with composite sensor and chemical oxygen demand (COD) measurements, respectively. Results clearly confirmed that, on the one hand, the cork-graphite sensor exhibited good current response to quantify of HCQ in the river water matrix, with limit of detection and quantification of 1.46 mg L−1 (≈3.36 µM) and 4.42 mg L−1 (≈10.19 µM), respectively. On the other hand, the electrochemical oxidation (EO) efficiently removed HCQ from real river water sample using BDD electrodes. Complete HCQ removal was achieved at all applied current densities; whereas in terms of COD, significant removals (68%, 71% and 84% at 15, 30 and 45 mA cm−2, respectively) were achieved. Based on the achieved results, the offline integration of electrochemical SDG6 technologies in order to monitor and remove HCQ is an efficient and effective strategy.
id UNSP_bb642c0ce06c9a29d70f53a1ef691c18
oai_identifier_str oai:repositorio.unesp.br:11449/223242
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water MatrixBoron doped diamond electrodeCorkCOVID-19Electrochemical oxidationHydroxychloroquineHydroxychloroquine (HCQ) has been extensively consumed due to the Coronavirus (COVID-19) pandemic. Therefore, it is increasingly found in different water matrices. For this reason, the concentration of HCQ in water should be monitored and the treatment of contaminated water matrices with HCQ is a key issue to overcome immediately. Thus, in this study, the development of technologies and smart water solutions to reach the Sustainable Development Goal 6 (SDG6) is the main objective. To do that, the integration of electrochemical technologies for their environmental application on HCQ detection, quantification and degradation was performed. Firstly, an electrochemical cork-graphite sensor was prepared to identify/quantify HCQ in river water matrices by differential pulse voltammetric (DPV) method. Subsequently, an HCQ-polluted river water sample was electrochemically treated with BDD electrode by applying 15, 30 and 45 mA cm−2. The HCQ decay and organic matter removal was monitored by DPV with composite sensor and chemical oxygen demand (COD) measurements, respectively. Results clearly confirmed that, on the one hand, the cork-graphite sensor exhibited good current response to quantify of HCQ in the river water matrix, with limit of detection and quantification of 1.46 mg L−1 (≈3.36 µM) and 4.42 mg L−1 (≈10.19 µM), respectively. On the other hand, the electrochemical oxidation (EO) efficiently removed HCQ from real river water sample using BDD electrodes. Complete HCQ removal was achieved at all applied current densities; whereas in terms of COD, significant removals (68%, 71% and 84% at 15, 30 and 45 mA cm−2, respectively) were achieved. Based on the achieved results, the offline integration of electrochemical SDG6 technologies in order to monitor and remove HCQ is an efficient and effective strategy.Laboratório de Eletroquímica Ambiental e Aplicada Instituto de Química Universidade Federal do Rio Grande do NorteNational Institute for Alternative Technologies of Detection Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM) Institute of Chemistry Universidade Estadual Paulista, P.O. Box 355Department of Chemistry University of Ferrara, Via Luigi Borsari 46National Institute for Alternative Technologies of Detection Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM) Institute of Chemistry Universidade Estadual Paulista, P.O. Box 355Universidade Federal do Rio Grande do NorteUniversidade Estadual Paulista (UNESP)University of Ferrarade Araújo, Danyelle MedeirosDos Santos, Elisama V. [UNESP]Martínez-Huitle, Carlos A. [UNESP]De Battisti, Achille2022-04-28T19:49:31Z2022-04-28T19:49:31Z2022-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.3390/app12020699Applied Sciences (Switzerland), v. 12, n. 2, 2022.2076-3417http://hdl.handle.net/11449/22324210.3390/app120206992-s2.0-85122734458Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengApplied Sciences (Switzerland)info:eu-repo/semantics/openAccess2022-04-28T19:49:31Zoai:repositorio.unesp.br:11449/223242Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T21:02:56.995224Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix
title Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix
spellingShingle Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix
de Araújo, Danyelle Medeiros
Boron doped diamond electrode
Cork
COVID-19
Electrochemical oxidation
Hydroxychloroquine
title_short Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix
title_full Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix
title_fullStr Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix
title_full_unstemmed Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix
title_sort Achieving Electrochemical-Sustainable-Based Solutions for Monitoring and Treating Hydroxychloroquine in Real Water Matrix
author de Araújo, Danyelle Medeiros
author_facet de Araújo, Danyelle Medeiros
Dos Santos, Elisama V. [UNESP]
Martínez-Huitle, Carlos A. [UNESP]
De Battisti, Achille
author_role author
author2 Dos Santos, Elisama V. [UNESP]
Martínez-Huitle, Carlos A. [UNESP]
De Battisti, Achille
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Federal do Rio Grande do Norte
Universidade Estadual Paulista (UNESP)
University of Ferrara
dc.contributor.author.fl_str_mv de Araújo, Danyelle Medeiros
Dos Santos, Elisama V. [UNESP]
Martínez-Huitle, Carlos A. [UNESP]
De Battisti, Achille
dc.subject.por.fl_str_mv Boron doped diamond electrode
Cork
COVID-19
Electrochemical oxidation
Hydroxychloroquine
topic Boron doped diamond electrode
Cork
COVID-19
Electrochemical oxidation
Hydroxychloroquine
description Hydroxychloroquine (HCQ) has been extensively consumed due to the Coronavirus (COVID-19) pandemic. Therefore, it is increasingly found in different water matrices. For this reason, the concentration of HCQ in water should be monitored and the treatment of contaminated water matrices with HCQ is a key issue to overcome immediately. Thus, in this study, the development of technologies and smart water solutions to reach the Sustainable Development Goal 6 (SDG6) is the main objective. To do that, the integration of electrochemical technologies for their environmental application on HCQ detection, quantification and degradation was performed. Firstly, an electrochemical cork-graphite sensor was prepared to identify/quantify HCQ in river water matrices by differential pulse voltammetric (DPV) method. Subsequently, an HCQ-polluted river water sample was electrochemically treated with BDD electrode by applying 15, 30 and 45 mA cm−2. The HCQ decay and organic matter removal was monitored by DPV with composite sensor and chemical oxygen demand (COD) measurements, respectively. Results clearly confirmed that, on the one hand, the cork-graphite sensor exhibited good current response to quantify of HCQ in the river water matrix, with limit of detection and quantification of 1.46 mg L−1 (≈3.36 µM) and 4.42 mg L−1 (≈10.19 µM), respectively. On the other hand, the electrochemical oxidation (EO) efficiently removed HCQ from real river water sample using BDD electrodes. Complete HCQ removal was achieved at all applied current densities; whereas in terms of COD, significant removals (68%, 71% and 84% at 15, 30 and 45 mA cm−2, respectively) were achieved. Based on the achieved results, the offline integration of electrochemical SDG6 technologies in order to monitor and remove HCQ is an efficient and effective strategy.
publishDate 2022
dc.date.none.fl_str_mv 2022-04-28T19:49:31Z
2022-04-28T19:49:31Z
2022-01-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.3390/app12020699
Applied Sciences (Switzerland), v. 12, n. 2, 2022.
2076-3417
http://hdl.handle.net/11449/223242
10.3390/app12020699
2-s2.0-85122734458
url http://dx.doi.org/10.3390/app12020699
http://hdl.handle.net/11449/223242
identifier_str_mv Applied Sciences (Switzerland), v. 12, n. 2, 2022.
2076-3417
10.3390/app12020699
2-s2.0-85122734458
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Applied Sciences (Switzerland)
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129277578706944