Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil

Detalhes bibliográficos
Autor(a) principal: Roveratti, Gabrielle [UNESP]
Data de Publicação: 2022
Outros Autores: Bonotto, Daniel Marcos [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.apradiso.2022.110399
http://hdl.handle.net/11449/242180
Resumo: This paper describes the use of gamma ray spectrometry in the study of rock samples from the Irati Formation, Paraná sedimentary basin, São Paulo State, Brazil. This technique allowed to measure the natural radiation emitted by 40K, as well the radionuclides belonging to the decay series of 238U (eU = 226Ra = 214Bi) and 232Th (eTh = 228Th = 208Tl) which occur in the analyzed samples. Four gamma ray spectrometers have been utilized for comparing the results obtained: a portable sodium iodide [NaI(Tl)] scintillation detector (Digidart), a handheld bismuth germanate oxide (BGO) detector and two bench NaI(Tl) crystals, differing in their geometry (Planar and Well types). This study involved the calibration of the spectrometers, except in the case of the BGO that is factory calibrated. Afterwards, gamma ray analysis was done for 122 rock samples colleted at Partecal Quarry located at Assistência District, Rio Claro city, which have been of interest for the oil and gas sector. For comparison purposes, the obtained datasets were subjected to different statistical tests, including the analysis of variance (ANOVA) that proved to be of great value for checking the differences of the mean concentration values of eU, eTh and K. The results pointed out several factors that affect the gamma ray analysis for the natural radioelements uranium, thorium, and potassium such as the samples size, shape and geometry, detector type, shielding and counting time. These factors are of difficult control in order to get reliable radiometric measurements by this technique.
id UNSP_bd02e1221b395df8b85ca3e3666dc816
oai_identifier_str oai:repositorio.unesp.br:11449/242180
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, BrazilBGO detectorGamma ray analysisIrati formationNaI(Tl) detectorParaná sedimentary basinThis paper describes the use of gamma ray spectrometry in the study of rock samples from the Irati Formation, Paraná sedimentary basin, São Paulo State, Brazil. This technique allowed to measure the natural radiation emitted by 40K, as well the radionuclides belonging to the decay series of 238U (eU = 226Ra = 214Bi) and 232Th (eTh = 228Th = 208Tl) which occur in the analyzed samples. Four gamma ray spectrometers have been utilized for comparing the results obtained: a portable sodium iodide [NaI(Tl)] scintillation detector (Digidart), a handheld bismuth germanate oxide (BGO) detector and two bench NaI(Tl) crystals, differing in their geometry (Planar and Well types). This study involved the calibration of the spectrometers, except in the case of the BGO that is factory calibrated. Afterwards, gamma ray analysis was done for 122 rock samples colleted at Partecal Quarry located at Assistência District, Rio Claro city, which have been of interest for the oil and gas sector. For comparison purposes, the obtained datasets were subjected to different statistical tests, including the analysis of variance (ANOVA) that proved to be of great value for checking the differences of the mean concentration values of eU, eTh and K. The results pointed out several factors that affect the gamma ray analysis for the natural radioelements uranium, thorium, and potassium such as the samples size, shape and geometry, detector type, shielding and counting time. These factors are of difficult control in order to get reliable radiometric measurements by this technique.Financiadora de Estudos e ProjetosIGCE-Instituto de Geociências e Ciências Exatas UNESP-Universidade Estadual Paulista, Av. 24-A No. 1515, P.O. Box 178, São PauloIGCE-Instituto de Geociências e Ciências Exatas UNESP-Universidade Estadual Paulista, Av. 24-A No. 1515, P.O. Box 178, São PauloUniversidade Estadual Paulista (UNESP)Roveratti, Gabrielle [UNESP]Bonotto, Daniel Marcos [UNESP]2023-03-02T11:27:37Z2023-03-02T11:27:37Z2022-10-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1016/j.apradiso.2022.110399Applied Radiation and Isotopes, v. 188.1872-98000969-8043http://hdl.handle.net/11449/24218010.1016/j.apradiso.2022.1103992-s2.0-85136332030Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengApplied Radiation and Isotopesinfo:eu-repo/semantics/openAccess2023-03-02T11:27:37Zoai:repositorio.unesp.br:11449/242180Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:39:30.774942Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil
title Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil
spellingShingle Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil
Roveratti, Gabrielle [UNESP]
BGO detector
Gamma ray analysis
Irati formation
NaI(Tl) detector
Paraná sedimentary basin
title_short Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil
title_full Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil
title_fullStr Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil
title_full_unstemmed Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil
title_sort Comparative analysis of gamma ray spectrometers applied to Irati Formation, Paraná basin, São Paulo State, Brazil
author Roveratti, Gabrielle [UNESP]
author_facet Roveratti, Gabrielle [UNESP]
Bonotto, Daniel Marcos [UNESP]
author_role author
author2 Bonotto, Daniel Marcos [UNESP]
author2_role author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Roveratti, Gabrielle [UNESP]
Bonotto, Daniel Marcos [UNESP]
dc.subject.por.fl_str_mv BGO detector
Gamma ray analysis
Irati formation
NaI(Tl) detector
Paraná sedimentary basin
topic BGO detector
Gamma ray analysis
Irati formation
NaI(Tl) detector
Paraná sedimentary basin
description This paper describes the use of gamma ray spectrometry in the study of rock samples from the Irati Formation, Paraná sedimentary basin, São Paulo State, Brazil. This technique allowed to measure the natural radiation emitted by 40K, as well the radionuclides belonging to the decay series of 238U (eU = 226Ra = 214Bi) and 232Th (eTh = 228Th = 208Tl) which occur in the analyzed samples. Four gamma ray spectrometers have been utilized for comparing the results obtained: a portable sodium iodide [NaI(Tl)] scintillation detector (Digidart), a handheld bismuth germanate oxide (BGO) detector and two bench NaI(Tl) crystals, differing in their geometry (Planar and Well types). This study involved the calibration of the spectrometers, except in the case of the BGO that is factory calibrated. Afterwards, gamma ray analysis was done for 122 rock samples colleted at Partecal Quarry located at Assistência District, Rio Claro city, which have been of interest for the oil and gas sector. For comparison purposes, the obtained datasets were subjected to different statistical tests, including the analysis of variance (ANOVA) that proved to be of great value for checking the differences of the mean concentration values of eU, eTh and K. The results pointed out several factors that affect the gamma ray analysis for the natural radioelements uranium, thorium, and potassium such as the samples size, shape and geometry, detector type, shielding and counting time. These factors are of difficult control in order to get reliable radiometric measurements by this technique.
publishDate 2022
dc.date.none.fl_str_mv 2022-10-01
2023-03-02T11:27:37Z
2023-03-02T11:27:37Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.apradiso.2022.110399
Applied Radiation and Isotopes, v. 188.
1872-9800
0969-8043
http://hdl.handle.net/11449/242180
10.1016/j.apradiso.2022.110399
2-s2.0-85136332030
url http://dx.doi.org/10.1016/j.apradiso.2022.110399
http://hdl.handle.net/11449/242180
identifier_str_mv Applied Radiation and Isotopes, v. 188.
1872-9800
0969-8043
10.1016/j.apradiso.2022.110399
2-s2.0-85136332030
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Applied Radiation and Isotopes
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129101335101440