The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1902/jop.2006.050290 http://hdl.handle.net/11449/231027 |
Resumo: | Background: Immunosuppressive agents may induce severe changes on bone metabolism and may impair the osseointegration process during the implant healing. No data are available concerning the influence of cyclosporin A on dental implants previously integrated to the bone. The aim of this study was to evaluate the influence of cyclosporin A administration on the mechanical retention of bone previously integrated to dental implants. Methods: Eighteen female New Zealand rabbits were submitted to an implant surgery. Each animal received one commercial dental implant of 10 × 3.75 mm. After 12 weeks of an undisturbed healing period, six animals were randomly sacrificed and the removal torque test was performed (group A). In addition, six animals were submitted to a daily injection of cyclosporin A in a dosage of 10 mg/kg (group C), and six animals received saline solution as a control (group B). After 12 weeks of cyclosporin A administration, groups B and C were sacrificed and submitted to a removal torque test in which higher values can be interpreted as higher mechanical bone retention to the implant surface or higher osseointegration. Results: The removal torque results were 30.5 (±9.8) Ncm for group A, 50.17 (±17.5) Ncm for group B, and 26 (±7.8) Ncm for group C. The statistical analysis showed significant differences between groups A and B (P <0.05) and groups B and C (P<0.01). Conclusion: Cyclosporin A administration may impair the mechanical retention of dental implants previously integrated to the bone. |
id |
UNSP_c9a803b471e2764132951edef77320fd |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/231027 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbitsCyclosporin ADental implantOsseointegrationTorqueBackground: Immunosuppressive agents may induce severe changes on bone metabolism and may impair the osseointegration process during the implant healing. No data are available concerning the influence of cyclosporin A on dental implants previously integrated to the bone. The aim of this study was to evaluate the influence of cyclosporin A administration on the mechanical retention of bone previously integrated to dental implants. Methods: Eighteen female New Zealand rabbits were submitted to an implant surgery. Each animal received one commercial dental implant of 10 × 3.75 mm. After 12 weeks of an undisturbed healing period, six animals were randomly sacrificed and the removal torque test was performed (group A). In addition, six animals were submitted to a daily injection of cyclosporin A in a dosage of 10 mg/kg (group C), and six animals received saline solution as a control (group B). After 12 weeks of cyclosporin A administration, groups B and C were sacrificed and submitted to a removal torque test in which higher values can be interpreted as higher mechanical bone retention to the implant surface or higher osseointegration. Results: The removal torque results were 30.5 (±9.8) Ncm for group A, 50.17 (±17.5) Ncm for group B, and 26 (±7.8) Ncm for group C. The statistical analysis showed significant differences between groups A and B (P <0.05) and groups B and C (P<0.01). Conclusion: Cyclosporin A administration may impair the mechanical retention of dental implants previously integrated to the bone.Department of Periodontology Educational Foundation of Barretos, Barretos, São PauloDepartment of Periodontology Dental School of Araraquara State University of São Paulo, Rua Humaitá 1680, Araraquara, São PauloEducational Foundation of BarretosUniversidade de São Paulo (USP)Sakakura, Celso E.Margonar, RogerioSartori, RafaelMorais, Juliana A.N.D.Marcantonio Jr., Elcio2022-04-29T08:43:17Z2022-04-29T08:43:17Z2006-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article2059-2062http://dx.doi.org/10.1902/jop.2006.050290Journal of Periodontology, v. 77, n. 12, p. 2059-2062, 2006.0022-3492http://hdl.handle.net/11449/23102710.1902/jop.2006.0502902-s2.0-33845724225Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Periodontologyinfo:eu-repo/semantics/openAccess2024-09-26T15:21:38Zoai:repositorio.unesp.br:11449/231027Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-26T15:21:38Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits |
title |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits |
spellingShingle |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits Sakakura, Celso E. Cyclosporin A Dental implant Osseointegration Torque |
title_short |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits |
title_full |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits |
title_fullStr |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits |
title_full_unstemmed |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits |
title_sort |
The influence of cyclosporin A on mechanical retention of dental implants previously integrated to the bone: A study in rabbits |
author |
Sakakura, Celso E. |
author_facet |
Sakakura, Celso E. Margonar, Rogerio Sartori, Rafael Morais, Juliana A.N.D. Marcantonio Jr., Elcio |
author_role |
author |
author2 |
Margonar, Rogerio Sartori, Rafael Morais, Juliana A.N.D. Marcantonio Jr., Elcio |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Educational Foundation of Barretos Universidade de São Paulo (USP) |
dc.contributor.author.fl_str_mv |
Sakakura, Celso E. Margonar, Rogerio Sartori, Rafael Morais, Juliana A.N.D. Marcantonio Jr., Elcio |
dc.subject.por.fl_str_mv |
Cyclosporin A Dental implant Osseointegration Torque |
topic |
Cyclosporin A Dental implant Osseointegration Torque |
description |
Background: Immunosuppressive agents may induce severe changes on bone metabolism and may impair the osseointegration process during the implant healing. No data are available concerning the influence of cyclosporin A on dental implants previously integrated to the bone. The aim of this study was to evaluate the influence of cyclosporin A administration on the mechanical retention of bone previously integrated to dental implants. Methods: Eighteen female New Zealand rabbits were submitted to an implant surgery. Each animal received one commercial dental implant of 10 × 3.75 mm. After 12 weeks of an undisturbed healing period, six animals were randomly sacrificed and the removal torque test was performed (group A). In addition, six animals were submitted to a daily injection of cyclosporin A in a dosage of 10 mg/kg (group C), and six animals received saline solution as a control (group B). After 12 weeks of cyclosporin A administration, groups B and C were sacrificed and submitted to a removal torque test in which higher values can be interpreted as higher mechanical bone retention to the implant surface or higher osseointegration. Results: The removal torque results were 30.5 (±9.8) Ncm for group A, 50.17 (±17.5) Ncm for group B, and 26 (±7.8) Ncm for group C. The statistical analysis showed significant differences between groups A and B (P <0.05) and groups B and C (P<0.01). Conclusion: Cyclosporin A administration may impair the mechanical retention of dental implants previously integrated to the bone. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-12-01 2022-04-29T08:43:17Z 2022-04-29T08:43:17Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1902/jop.2006.050290 Journal of Periodontology, v. 77, n. 12, p. 2059-2062, 2006. 0022-3492 http://hdl.handle.net/11449/231027 10.1902/jop.2006.050290 2-s2.0-33845724225 |
url |
http://dx.doi.org/10.1902/jop.2006.050290 http://hdl.handle.net/11449/231027 |
identifier_str_mv |
Journal of Periodontology, v. 77, n. 12, p. 2059-2062, 2006. 0022-3492 10.1902/jop.2006.050290 2-s2.0-33845724225 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of Periodontology |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
2059-2062 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546445861552128 |