Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.2319/040313-255.1 http://hdl.handle.net/11449/112515 |
Resumo: | Objective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts. |
id |
UNSP_d534215a82300dfd73a0b94f98d7554c |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/112515 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurementsAnatomic modelsCone-beam computed tomographyOrthodonticsObjective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Sao Paulo, BrazilSao Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Sao Paulo, BrazilUniv Fed Fluminense, Sch Dent, Area Radiol, Dept Specif Format, Nova Friburgo, RJ, BrazilSao Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Oral Diag & Surg, Sao Paulo, BrazilSao Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Sao Paulo, BrazilSao Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Oral Diag & Surg, Sao Paulo, BrazilE H Angle Education Research Foundation, IncUniversidade Estadual de Campinas (UNICAMP)Universidade Estadual Paulista (Unesp)Universidade Federal Fluminense (UFF)Gamba, Thiago O.Oliveira, Matheus L. [UNESP]Flores, Isadora L.Cruz, Adriana D.Almeida, Solange M.Haiter-Neto, FranciscoLopes, Sergio L. P. C. [UNESP]2014-12-03T13:10:47Z2014-12-03T13:10:47Z2014-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article274-278application/pdfhttp://dx.doi.org/10.2319/040313-255.1Angle Orthodontist. Newton N: E H Angle Education Research Foundation, Inc, v. 84, n. 2, p. 274-278, 2014.0003-3219http://hdl.handle.net/11449/11251510.2319/040313-255.1WOS:000332821600011WOS000332821600011.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengAngle Orthodontist1.5921,267info:eu-repo/semantics/openAccess2024-09-26T15:21:38Zoai:repositorio.unesp.br:11449/112515Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-26T15:21:38Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements |
title |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements |
spellingShingle |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements Gamba, Thiago O. Anatomic models Cone-beam computed tomography Orthodontics |
title_short |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements |
title_full |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements |
title_fullStr |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements |
title_full_unstemmed |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements |
title_sort |
Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements |
author |
Gamba, Thiago O. |
author_facet |
Gamba, Thiago O. Oliveira, Matheus L. [UNESP] Flores, Isadora L. Cruz, Adriana D. Almeida, Solange M. Haiter-Neto, Francisco Lopes, Sergio L. P. C. [UNESP] |
author_role |
author |
author2 |
Oliveira, Matheus L. [UNESP] Flores, Isadora L. Cruz, Adriana D. Almeida, Solange M. Haiter-Neto, Francisco Lopes, Sergio L. P. C. [UNESP] |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual de Campinas (UNICAMP) Universidade Estadual Paulista (Unesp) Universidade Federal Fluminense (UFF) |
dc.contributor.author.fl_str_mv |
Gamba, Thiago O. Oliveira, Matheus L. [UNESP] Flores, Isadora L. Cruz, Adriana D. Almeida, Solange M. Haiter-Neto, Francisco Lopes, Sergio L. P. C. [UNESP] |
dc.subject.por.fl_str_mv |
Anatomic models Cone-beam computed tomography Orthodontics |
topic |
Anatomic models Cone-beam computed tomography Orthodontics |
description |
Objective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-03T13:10:47Z 2014-12-03T13:10:47Z 2014-03-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.2319/040313-255.1 Angle Orthodontist. Newton N: E H Angle Education Research Foundation, Inc, v. 84, n. 2, p. 274-278, 2014. 0003-3219 http://hdl.handle.net/11449/112515 10.2319/040313-255.1 WOS:000332821600011 WOS000332821600011.pdf |
url |
http://dx.doi.org/10.2319/040313-255.1 http://hdl.handle.net/11449/112515 |
identifier_str_mv |
Angle Orthodontist. Newton N: E H Angle Education Research Foundation, Inc, v. 84, n. 2, p. 274-278, 2014. 0003-3219 10.2319/040313-255.1 WOS:000332821600011 WOS000332821600011.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Angle Orthodontist 1.592 1,267 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
274-278 application/pdf |
dc.publisher.none.fl_str_mv |
E H Angle Education Research Foundation, Inc |
publisher.none.fl_str_mv |
E H Angle Education Research Foundation, Inc |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546447330607104 |