Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements

Detalhes bibliográficos
Autor(a) principal: Gamba, Thiago O.
Data de Publicação: 2014
Outros Autores: Oliveira, Matheus L. [UNESP], Flores, Isadora L., Cruz, Adriana D., Almeida, Solange M., Haiter-Neto, Francisco, Lopes, Sergio L. P. C. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.2319/040313-255.1
http://hdl.handle.net/11449/112515
Resumo: Objective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.
id UNSP_d534215a82300dfd73a0b94f98d7554c
oai_identifier_str oai:repositorio.unesp.br:11449/112515
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurementsAnatomic modelsCone-beam computed tomographyOrthodonticsObjective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Sao Paulo, BrazilSao Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Sao Paulo, BrazilUniv Fed Fluminense, Sch Dent, Area Radiol, Dept Specif Format, Nova Friburgo, RJ, BrazilSao Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Oral Diag & Surg, Sao Paulo, BrazilSao Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Sao Paulo, BrazilSao Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Oral Diag & Surg, Sao Paulo, BrazilE H Angle Education Research Foundation, IncUniversidade Estadual de Campinas (UNICAMP)Universidade Estadual Paulista (Unesp)Universidade Federal Fluminense (UFF)Gamba, Thiago O.Oliveira, Matheus L. [UNESP]Flores, Isadora L.Cruz, Adriana D.Almeida, Solange M.Haiter-Neto, FranciscoLopes, Sergio L. P. C. [UNESP]2014-12-03T13:10:47Z2014-12-03T13:10:47Z2014-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article274-278application/pdfhttp://dx.doi.org/10.2319/040313-255.1Angle Orthodontist. Newton N: E H Angle Education Research Foundation, Inc, v. 84, n. 2, p. 274-278, 2014.0003-3219http://hdl.handle.net/11449/11251510.2319/040313-255.1WOS:000332821600011WOS000332821600011.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengAngle Orthodontist1.5921,267info:eu-repo/semantics/openAccess2024-09-26T15:21:38Zoai:repositorio.unesp.br:11449/112515Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-26T15:21:38Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
title Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
spellingShingle Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
Gamba, Thiago O.
Anatomic models
Cone-beam computed tomography
Orthodontics
title_short Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
title_full Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
title_fullStr Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
title_full_unstemmed Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
title_sort Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements
author Gamba, Thiago O.
author_facet Gamba, Thiago O.
Oliveira, Matheus L. [UNESP]
Flores, Isadora L.
Cruz, Adriana D.
Almeida, Solange M.
Haiter-Neto, Francisco
Lopes, Sergio L. P. C. [UNESP]
author_role author
author2 Oliveira, Matheus L. [UNESP]
Flores, Isadora L.
Cruz, Adriana D.
Almeida, Solange M.
Haiter-Neto, Francisco
Lopes, Sergio L. P. C. [UNESP]
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual de Campinas (UNICAMP)
Universidade Estadual Paulista (Unesp)
Universidade Federal Fluminense (UFF)
dc.contributor.author.fl_str_mv Gamba, Thiago O.
Oliveira, Matheus L. [UNESP]
Flores, Isadora L.
Cruz, Adriana D.
Almeida, Solange M.
Haiter-Neto, Francisco
Lopes, Sergio L. P. C. [UNESP]
dc.subject.por.fl_str_mv Anatomic models
Cone-beam computed tomography
Orthodontics
topic Anatomic models
Cone-beam computed tomography
Orthodontics
description Objective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.
publishDate 2014
dc.date.none.fl_str_mv 2014-12-03T13:10:47Z
2014-12-03T13:10:47Z
2014-03-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.2319/040313-255.1
Angle Orthodontist. Newton N: E H Angle Education Research Foundation, Inc, v. 84, n. 2, p. 274-278, 2014.
0003-3219
http://hdl.handle.net/11449/112515
10.2319/040313-255.1
WOS:000332821600011
WOS000332821600011.pdf
url http://dx.doi.org/10.2319/040313-255.1
http://hdl.handle.net/11449/112515
identifier_str_mv Angle Orthodontist. Newton N: E H Angle Education Research Foundation, Inc, v. 84, n. 2, p. 274-278, 2014.
0003-3219
10.2319/040313-255.1
WOS:000332821600011
WOS000332821600011.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Angle Orthodontist
1.592
1,267
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 274-278
application/pdf
dc.publisher.none.fl_str_mv E H Angle Education Research Foundation, Inc
publisher.none.fl_str_mv E H Angle Education Research Foundation, Inc
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546447330607104