Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1109/ISGT-LA.2019.8895385 http://hdl.handle.net/11449/221407 |
Resumo: | This work proposes a method to calculate the short- circuit currents in unbalanced three-phase power distribution systems with distributed generation (DG) from non- and renewable energy resources. It takes into account the physical and operational features of four different types of DGs: synchronous, induction, photovoltaic and double-fed induction generator (DFIG). The DG formulations depend upon the connection type that can be directly coupling to the power grid or by using electronic converters or coupling transformers. The proposed method uses the bus impedance matrix with Kron reduction for each generator and superposition conception in the short-circuit current calculation. The results are achieved under a real-work unbalanced distribution network with 135 buses providing typical values of the short-circuit current that are compared with values from commercial software in the evaluation of the proposed methodology. |
id |
UNSP_d5705adda45cc23648729045a0de7197 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/221407 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed GenerationBus Impedance MatrixDistributed GenerationElectrical Power Distribution SystemKron ReductionNon- and Renewable Energy ResourceShort-CircuitThis work proposes a method to calculate the short- circuit currents in unbalanced three-phase power distribution systems with distributed generation (DG) from non- and renewable energy resources. It takes into account the physical and operational features of four different types of DGs: synchronous, induction, photovoltaic and double-fed induction generator (DFIG). The DG formulations depend upon the connection type that can be directly coupling to the power grid or by using electronic converters or coupling transformers. The proposed method uses the bus impedance matrix with Kron reduction for each generator and superposition conception in the short-circuit current calculation. The results are achieved under a real-work unbalanced distribution network with 135 buses providing typical values of the short-circuit current that are compared with values from commercial software in the evaluation of the proposed methodology.São Paulo State University Dep. of Electrical EngineeringSão Paulo State University Dep. of Electrical EngineeringUniversidade Estadual Paulista (UNESP)Reiz, Cleberton [UNESP]Leite, Jônatas Boás [UNESP]2022-04-28T19:28:20Z2022-04-28T19:28:20Z2019-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjecthttp://dx.doi.org/10.1109/ISGT-LA.2019.88953852019 IEEE PES Conference on Innovative Smart Grid Technologies, ISGT Latin America 2019.http://hdl.handle.net/11449/22140710.1109/ISGT-LA.2019.88953852-s2.0-85075766482Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPeng2019 IEEE PES Conference on Innovative Smart Grid Technologies, ISGT Latin America 2019info:eu-repo/semantics/openAccess2022-04-28T19:28:20Zoai:repositorio.unesp.br:11449/221407Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T22:23:00.025913Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation |
title |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation |
spellingShingle |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation Reiz, Cleberton [UNESP] Bus Impedance Matrix Distributed Generation Electrical Power Distribution System Kron Reduction Non- and Renewable Energy Resource Short-Circuit |
title_short |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation |
title_full |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation |
title_fullStr |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation |
title_full_unstemmed |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation |
title_sort |
Short-Circuit Calculation in Unbalanced Three-Phase Power Distribution Systems with Distributed Generation |
author |
Reiz, Cleberton [UNESP] |
author_facet |
Reiz, Cleberton [UNESP] Leite, Jônatas Boás [UNESP] |
author_role |
author |
author2 |
Leite, Jônatas Boás [UNESP] |
author2_role |
author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Reiz, Cleberton [UNESP] Leite, Jônatas Boás [UNESP] |
dc.subject.por.fl_str_mv |
Bus Impedance Matrix Distributed Generation Electrical Power Distribution System Kron Reduction Non- and Renewable Energy Resource Short-Circuit |
topic |
Bus Impedance Matrix Distributed Generation Electrical Power Distribution System Kron Reduction Non- and Renewable Energy Resource Short-Circuit |
description |
This work proposes a method to calculate the short- circuit currents in unbalanced three-phase power distribution systems with distributed generation (DG) from non- and renewable energy resources. It takes into account the physical and operational features of four different types of DGs: synchronous, induction, photovoltaic and double-fed induction generator (DFIG). The DG formulations depend upon the connection type that can be directly coupling to the power grid or by using electronic converters or coupling transformers. The proposed method uses the bus impedance matrix with Kron reduction for each generator and superposition conception in the short-circuit current calculation. The results are achieved under a real-work unbalanced distribution network with 135 buses providing typical values of the short-circuit current that are compared with values from commercial software in the evaluation of the proposed methodology. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-09-01 2022-04-28T19:28:20Z 2022-04-28T19:28:20Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1109/ISGT-LA.2019.8895385 2019 IEEE PES Conference on Innovative Smart Grid Technologies, ISGT Latin America 2019. http://hdl.handle.net/11449/221407 10.1109/ISGT-LA.2019.8895385 2-s2.0-85075766482 |
url |
http://dx.doi.org/10.1109/ISGT-LA.2019.8895385 http://hdl.handle.net/11449/221407 |
identifier_str_mv |
2019 IEEE PES Conference on Innovative Smart Grid Technologies, ISGT Latin America 2019. 10.1109/ISGT-LA.2019.8895385 2-s2.0-85075766482 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2019 IEEE PES Conference on Innovative Smart Grid Technologies, ISGT Latin America 2019 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128237804453888 |