Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study

Detalhes bibliográficos
Autor(a) principal: Wittmaack, Monica Carolina Nery [UNESP]
Data de Publicação: 2022
Outros Autores: Sembenelli, Guilherme, Conceição, Maria Eduarda Bastos Andrade Moutinho da [UNESP], Montanhim, Gabriel Luiz [UNESP], Crivellaro, Roberta Martins [UNESP], Rolemberg, Daniele Santos [UNESP], Dias, Luis Gustavo Gosuen Gonçalves [UNESP], Silva, Marco Augusto Machado da, Teixeira, Pedro Paulo Maia, Moraes, Paola Castro [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/0103-8478cr20210230
http://hdl.handle.net/11449/236892
Resumo: Thoracoscopy is replacing open lung biopsies because it is less invasive, usually the technique is done using three portals and intracorporeal suture technique. This study described the feasibility and efficacy of a novel pre tied loop ligature and to propose a thoracoscopic access strategy with two portals to perform lung biopsy in patients under 5 kg. Ten rabbits were positioned in dorsal recumbency. Total thoracoscopic lung biopsy was performed using a combined transdiaphragmatic approach and a right intercostal approach. A pre tied loop ligature was placed to perform a caudal lung lobe biopsy. Insufflation of the thoracic cavity was not performed. The total surgery time was 41.4 ± 14.5 min. The procedure was carried out free of complications that prevented slippage or tightening the knot or that made it come loose after the lung biopsy; there was no serious complication during the surgical procedure. The samples obtained averaged 1x0.64x0.45 cm (Length, Width, Depth) and were considered satisfactory according to the histopathologic evaluation. Thorax radiographs taken before and after the surgeries were compared and showed no pneumothorax or hemothorax. Necropsy confirmed no knot failure occurred at the biopsy site. The use of the novel pre tied loop ligature is a safe and effective technique, avoiding problems with the limited size of the thoracic cavity in small patients.
id UNSP_d59643987113d61d176c144bf3e3450f
oai_identifier_str oai:repositorio.unesp.br:11449/236892
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental studyBiópsia pulmonar por toracoscopia por dois portais com uma nova ligadura de alça pré-amarrada em coelhos: um estudo experimentalendolooplung biopsysmall patientsthoracic surgerytransdiaphragmatic thoracoscopy and videosurgerybiópsia pulmonarcirurgia torácicaendolooppequenos animaistoracoscopia transdiafragática e videocirurgiaThoracoscopy is replacing open lung biopsies because it is less invasive, usually the technique is done using three portals and intracorporeal suture technique. This study described the feasibility and efficacy of a novel pre tied loop ligature and to propose a thoracoscopic access strategy with two portals to perform lung biopsy in patients under 5 kg. Ten rabbits were positioned in dorsal recumbency. Total thoracoscopic lung biopsy was performed using a combined transdiaphragmatic approach and a right intercostal approach. A pre tied loop ligature was placed to perform a caudal lung lobe biopsy. Insufflation of the thoracic cavity was not performed. The total surgery time was 41.4 ± 14.5 min. The procedure was carried out free of complications that prevented slippage or tightening the knot or that made it come loose after the lung biopsy; there was no serious complication during the surgical procedure. The samples obtained averaged 1x0.64x0.45 cm (Length, Width, Depth) and were considered satisfactory according to the histopathologic evaluation. Thorax radiographs taken before and after the surgeries were compared and showed no pneumothorax or hemothorax. Necropsy confirmed no knot failure occurred at the biopsy site. The use of the novel pre tied loop ligature is a safe and effective technique, avoiding problems with the limited size of the thoracic cavity in small patients.A toracoscopia está substituindo as biópsias pulmonares abertas por ser menos invasiva. Usualmente a técnica é feita utilizando três portais e ligaduras feitas intra corporalmente. O objetivo deste estudo foi descrever a viabilidade e eficácia de uma nova ligadura com alça pré-amarrada e propor uma estratégia de acesso toracoscópico com dois portais para realizar biópsia pulmonar em pacientes com menos de 5kg. Dez coelhos foram posicionados em decúbito dorsal. A biópsia pulmonar por toracoscopia total foi feita pela abordagem combinada transdiafragmática e abordagem intercostal direita. Uma nova ligadura pré-amarrada foi colocada para realizar uma biópsia do lobo pulmonar caudal. Não foi realizada insuflação da cavidade torácica. O tempo total de cirurgia foi de 41,4 ± 14,5 min. Os procedimentos foram realizados sem complicações que impedissem o escorregamento ou aperto do nó ou que o soltassem após a biópsia pulmonar; não houve nenhuma intercorrência grave durante o procedimento cirúrgico. As amostras coletadas tinham tamanho médio 1x0,64x0,45 cm e foram consideradas satisfatórias de acordo com a avaliação histopatológica. As radiografias de tórax feitas antes e depois das cirurgias foram comparadas e não mostraram pneumotórax ou hemotórax. A necropsia confirmou que não ocorreu falha do nó no local da biópsia. Conclui-se que uso da nova ligadura com alça pré-amarrada é uma técnica segura e eficaz, evitando problemas com o tamanho limitado da cavidade torácica em pacientes pequenos.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Universidade Estadual Paulista (UNESP), Departamento de Clínica e Cirurgia VeterináriaCentro Universitário Moura LacerdaUniversidade Federal de Goiás (UFG), Escola de Veterinária e ZootecniaUniversidade Federal do Pará (UFPA), Instituto de Medicina VeterináriaUniversidade Estadual Paulista (UNESP), Departamento de Clínica e Cirurgia VeterináriaFAPESP: 2015/199651Universidade Federal de Santa MariaUniversidade Estadual Paulista (UNESP)Centro Universitário Moura LacerdaUniversidade Federal de Goiás (UFG)Universidade Federal do Pará (UFPA)Wittmaack, Monica Carolina Nery [UNESP]Sembenelli, GuilhermeConceição, Maria Eduarda Bastos Andrade Moutinho da [UNESP]Montanhim, Gabriel Luiz [UNESP]Crivellaro, Roberta Martins [UNESP]Rolemberg, Daniele Santos [UNESP]Dias, Luis Gustavo Gosuen Gonçalves [UNESP]Silva, Marco Augusto Machado daTeixeira, Pedro Paulo MaiaMoraes, Paola Castro [UNESP]2022-10-10T13:56:05Z2022-10-10T13:56:05Z2022-06-06info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article-application/pdfhttp://dx.doi.org/10.1590/0103-8478cr20210230Ciência Rural. Universidade Federal de Santa Maria, v. 53, n. 2, p. -, 2022.0103-84781678-4596http://hdl.handle.net/11449/23689210.1590/0103-8478cr20210230S0103-84782023000200601S0103-84782023000200601.pdfSciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengCiência Ruralinfo:eu-repo/semantics/openAccess2023-10-28T06:05:04Zoai:repositorio.unesp.br:11449/236892Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T16:13:25.910166Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study
Biópsia pulmonar por toracoscopia por dois portais com uma nova ligadura de alça pré-amarrada em coelhos: um estudo experimental
title Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study
spellingShingle Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study
Wittmaack, Monica Carolina Nery [UNESP]
endoloop
lung biopsy
small patients
thoracic surgery
transdiaphragmatic thoracoscopy and videosurgery
biópsia pulmonar
cirurgia torácica
endoloop
pequenos animais
toracoscopia transdiafragática e videocirurgia
title_short Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study
title_full Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study
title_fullStr Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study
title_full_unstemmed Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study
title_sort Thoracoscopy pulmonary biopsy by two portals with a novel pre-tied loop ligature device in rabbits: an experimental study
author Wittmaack, Monica Carolina Nery [UNESP]
author_facet Wittmaack, Monica Carolina Nery [UNESP]
Sembenelli, Guilherme
Conceição, Maria Eduarda Bastos Andrade Moutinho da [UNESP]
Montanhim, Gabriel Luiz [UNESP]
Crivellaro, Roberta Martins [UNESP]
Rolemberg, Daniele Santos [UNESP]
Dias, Luis Gustavo Gosuen Gonçalves [UNESP]
Silva, Marco Augusto Machado da
Teixeira, Pedro Paulo Maia
Moraes, Paola Castro [UNESP]
author_role author
author2 Sembenelli, Guilherme
Conceição, Maria Eduarda Bastos Andrade Moutinho da [UNESP]
Montanhim, Gabriel Luiz [UNESP]
Crivellaro, Roberta Martins [UNESP]
Rolemberg, Daniele Santos [UNESP]
Dias, Luis Gustavo Gosuen Gonçalves [UNESP]
Silva, Marco Augusto Machado da
Teixeira, Pedro Paulo Maia
Moraes, Paola Castro [UNESP]
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
Centro Universitário Moura Lacerda
Universidade Federal de Goiás (UFG)
Universidade Federal do Pará (UFPA)
dc.contributor.author.fl_str_mv Wittmaack, Monica Carolina Nery [UNESP]
Sembenelli, Guilherme
Conceição, Maria Eduarda Bastos Andrade Moutinho da [UNESP]
Montanhim, Gabriel Luiz [UNESP]
Crivellaro, Roberta Martins [UNESP]
Rolemberg, Daniele Santos [UNESP]
Dias, Luis Gustavo Gosuen Gonçalves [UNESP]
Silva, Marco Augusto Machado da
Teixeira, Pedro Paulo Maia
Moraes, Paola Castro [UNESP]
dc.subject.por.fl_str_mv endoloop
lung biopsy
small patients
thoracic surgery
transdiaphragmatic thoracoscopy and videosurgery
biópsia pulmonar
cirurgia torácica
endoloop
pequenos animais
toracoscopia transdiafragática e videocirurgia
topic endoloop
lung biopsy
small patients
thoracic surgery
transdiaphragmatic thoracoscopy and videosurgery
biópsia pulmonar
cirurgia torácica
endoloop
pequenos animais
toracoscopia transdiafragática e videocirurgia
description Thoracoscopy is replacing open lung biopsies because it is less invasive, usually the technique is done using three portals and intracorporeal suture technique. This study described the feasibility and efficacy of a novel pre tied loop ligature and to propose a thoracoscopic access strategy with two portals to perform lung biopsy in patients under 5 kg. Ten rabbits were positioned in dorsal recumbency. Total thoracoscopic lung biopsy was performed using a combined transdiaphragmatic approach and a right intercostal approach. A pre tied loop ligature was placed to perform a caudal lung lobe biopsy. Insufflation of the thoracic cavity was not performed. The total surgery time was 41.4 ± 14.5 min. The procedure was carried out free of complications that prevented slippage or tightening the knot or that made it come loose after the lung biopsy; there was no serious complication during the surgical procedure. The samples obtained averaged 1x0.64x0.45 cm (Length, Width, Depth) and were considered satisfactory according to the histopathologic evaluation. Thorax radiographs taken before and after the surgeries were compared and showed no pneumothorax or hemothorax. Necropsy confirmed no knot failure occurred at the biopsy site. The use of the novel pre tied loop ligature is a safe and effective technique, avoiding problems with the limited size of the thoracic cavity in small patients.
publishDate 2022
dc.date.none.fl_str_mv 2022-10-10T13:56:05Z
2022-10-10T13:56:05Z
2022-06-06
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/0103-8478cr20210230
Ciência Rural. Universidade Federal de Santa Maria, v. 53, n. 2, p. -, 2022.
0103-8478
1678-4596
http://hdl.handle.net/11449/236892
10.1590/0103-8478cr20210230
S0103-84782023000200601
S0103-84782023000200601.pdf
url http://dx.doi.org/10.1590/0103-8478cr20210230
http://hdl.handle.net/11449/236892
identifier_str_mv Ciência Rural. Universidade Federal de Santa Maria, v. 53, n. 2, p. -, 2022.
0103-8478
1678-4596
10.1590/0103-8478cr20210230
S0103-84782023000200601
S0103-84782023000200601.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Ciência Rural
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv -
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
publisher.none.fl_str_mv Universidade Federal de Santa Maria
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128619720998912