Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation

Detalhes bibliográficos
Autor(a) principal: Machado, Ana Lucia [UNESP]
Data de Publicação: 2012
Outros Autores: Giampaolo, Eunice Teresinha [UNESP], Pavarina, Ana Claudia [UNESP], Jorge, Janaina Habib [UNESP], Vergani, Carlos Eduardo [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
DOI: 10.1111/j.1741-2358.2011.00484.x
Texto Completo: http://dx.doi.org/10.1111/j.1741-2358.2011.00484.x
http://hdl.handle.net/11449/16506
Resumo: Background: This study evaluated the effect of disinfection by immersion and microwave irradiation on the roughness of one denture base resin (Lucitone-L) and five relining materials, three hard (Tokuyama Rebase II-TR, New Truliner-NT, Ufigel Hard-UH) and two resilient (Trusoft-T, Sofreliner-S).Methods: Fifty specimens were made and divided into groups: CL2 specimens were brushed with 4% chlorhexidine (1 min), immersed in the same solution (10 min) and immersed in water (3 min); MW2 specimens were immersed in water and microwave irradiated (650W; 6 min); CL2 and MW2 specimens were disinfected twice; CL7 and MW7 specimens were submitted to seven cycles using chlorhexidine or microwave irradiation, respectively; W specimens were not disinfected and remained in water (37 degrees C; 7 days).Results: Results were statistically analysed (p = 0.05) and revealed that, at baseline, the highest mean value was observed for T (p < 0.001). Material NT showed increase in roughness after the first (p = 0.003), second (p = 0.001), seventh (p = 0.000) cycles of microwave disinfection and after 7 days of immersion in water (p = 0.033).Conclusions: Resilient liner S presented significant increase in roughness after the second cycle of disinfection with chlorhexidine (p = 0.003). Material T exhibited significantly decreased roughness in group W (p = 0.010), while microwaving produced severe alterations on its surface.
id UNSP_d6b15ce7310b663fcfa983dd5bf5deb3
oai_identifier_str oai:repositorio.unesp.br:11449/16506
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiationchemical compoundsdenture basesdenture rebasingmicrowavessurface propertiesBackground: This study evaluated the effect of disinfection by immersion and microwave irradiation on the roughness of one denture base resin (Lucitone-L) and five relining materials, three hard (Tokuyama Rebase II-TR, New Truliner-NT, Ufigel Hard-UH) and two resilient (Trusoft-T, Sofreliner-S).Methods: Fifty specimens were made and divided into groups: CL2 specimens were brushed with 4% chlorhexidine (1 min), immersed in the same solution (10 min) and immersed in water (3 min); MW2 specimens were immersed in water and microwave irradiated (650W; 6 min); CL2 and MW2 specimens were disinfected twice; CL7 and MW7 specimens were submitted to seven cycles using chlorhexidine or microwave irradiation, respectively; W specimens were not disinfected and remained in water (37 degrees C; 7 days).Results: Results were statistically analysed (p = 0.05) and revealed that, at baseline, the highest mean value was observed for T (p < 0.001). Material NT showed increase in roughness after the first (p = 0.003), second (p = 0.001), seventh (p = 0.000) cycles of microwave disinfection and after 7 days of immersion in water (p = 0.033).Conclusions: Resilient liner S presented significant increase in roughness after the second cycle of disinfection with chlorhexidine (p = 0.003). Material T exhibited significantly decreased roughness in group W (p = 0.010), while microwaving produced severe alterations on its surface.Univ Estadual Paulista UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, BrazilUniversidade Estadual de Ponta Grossa (UEPG), Dept Dent, Maringa, Parana, BrazilUniv Estadual Paulista UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, BrazilWiley-BlackwellUniversidade Estadual Paulista (Unesp)Universidade Estadual de Ponta Grossa (UEPG)Machado, Ana Lucia [UNESP]Giampaolo, Eunice Teresinha [UNESP]Pavarina, Ana Claudia [UNESP]Jorge, Janaina Habib [UNESP]Vergani, Carlos Eduardo [UNESP]2014-05-20T13:46:36Z2014-05-20T13:46:36Z2012-06-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleE375-E382http://dx.doi.org/10.1111/j.1741-2358.2011.00484.xGerodontology. Hoboken: Wiley-blackwell, v. 29, n. 2, p. E375-E382, 2012.0734-0664http://hdl.handle.net/11449/1650610.1111/j.1741-2358.2011.00484.xWOS:00030854700005580002487818425875737127334248549886767053910540330031305224278200000-0002-7375-4714Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengGerodontology1.4390,627info:eu-repo/semantics/openAccess2024-09-27T14:57:18Zoai:repositorio.unesp.br:11449/16506Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T14:57:18Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
title Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
spellingShingle Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
Machado, Ana Lucia [UNESP]
chemical compounds
denture bases
denture rebasing
microwaves
surface properties
Machado, Ana Lucia [UNESP]
chemical compounds
denture bases
denture rebasing
microwaves
surface properties
title_short Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
title_full Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
title_fullStr Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
title_full_unstemmed Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
title_sort Surface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiation
author Machado, Ana Lucia [UNESP]
author_facet Machado, Ana Lucia [UNESP]
Machado, Ana Lucia [UNESP]
Giampaolo, Eunice Teresinha [UNESP]
Pavarina, Ana Claudia [UNESP]
Jorge, Janaina Habib [UNESP]
Vergani, Carlos Eduardo [UNESP]
Giampaolo, Eunice Teresinha [UNESP]
Pavarina, Ana Claudia [UNESP]
Jorge, Janaina Habib [UNESP]
Vergani, Carlos Eduardo [UNESP]
author_role author
author2 Giampaolo, Eunice Teresinha [UNESP]
Pavarina, Ana Claudia [UNESP]
Jorge, Janaina Habib [UNESP]
Vergani, Carlos Eduardo [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade Estadual de Ponta Grossa (UEPG)
dc.contributor.author.fl_str_mv Machado, Ana Lucia [UNESP]
Giampaolo, Eunice Teresinha [UNESP]
Pavarina, Ana Claudia [UNESP]
Jorge, Janaina Habib [UNESP]
Vergani, Carlos Eduardo [UNESP]
dc.subject.por.fl_str_mv chemical compounds
denture bases
denture rebasing
microwaves
surface properties
topic chemical compounds
denture bases
denture rebasing
microwaves
surface properties
description Background: This study evaluated the effect of disinfection by immersion and microwave irradiation on the roughness of one denture base resin (Lucitone-L) and five relining materials, three hard (Tokuyama Rebase II-TR, New Truliner-NT, Ufigel Hard-UH) and two resilient (Trusoft-T, Sofreliner-S).Methods: Fifty specimens were made and divided into groups: CL2 specimens were brushed with 4% chlorhexidine (1 min), immersed in the same solution (10 min) and immersed in water (3 min); MW2 specimens were immersed in water and microwave irradiated (650W; 6 min); CL2 and MW2 specimens were disinfected twice; CL7 and MW7 specimens were submitted to seven cycles using chlorhexidine or microwave irradiation, respectively; W specimens were not disinfected and remained in water (37 degrees C; 7 days).Results: Results were statistically analysed (p = 0.05) and revealed that, at baseline, the highest mean value was observed for T (p < 0.001). Material NT showed increase in roughness after the first (p = 0.003), second (p = 0.001), seventh (p = 0.000) cycles of microwave disinfection and after 7 days of immersion in water (p = 0.033).Conclusions: Resilient liner S presented significant increase in roughness after the second cycle of disinfection with chlorhexidine (p = 0.003). Material T exhibited significantly decreased roughness in group W (p = 0.010), while microwaving produced severe alterations on its surface.
publishDate 2012
dc.date.none.fl_str_mv 2012-06-01
2014-05-20T13:46:36Z
2014-05-20T13:46:36Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1111/j.1741-2358.2011.00484.x
Gerodontology. Hoboken: Wiley-blackwell, v. 29, n. 2, p. E375-E382, 2012.
0734-0664
http://hdl.handle.net/11449/16506
10.1111/j.1741-2358.2011.00484.x
WOS:000308547000055
8000248781842587
5737127334248549
8867670539105403
3003130522427820
0000-0002-7375-4714
url http://dx.doi.org/10.1111/j.1741-2358.2011.00484.x
http://hdl.handle.net/11449/16506
identifier_str_mv Gerodontology. Hoboken: Wiley-blackwell, v. 29, n. 2, p. E375-E382, 2012.
0734-0664
10.1111/j.1741-2358.2011.00484.x
WOS:000308547000055
8000248781842587
5737127334248549
8867670539105403
3003130522427820
0000-0002-7375-4714
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Gerodontology
1.439
0,627
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv E375-E382
dc.publisher.none.fl_str_mv Wiley-Blackwell
publisher.none.fl_str_mv Wiley-Blackwell
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1822219178836230144
dc.identifier.doi.none.fl_str_mv 10.1111/j.1741-2358.2011.00484.x