Deformation of nickel-titanium closed coil springs: An in vitro study

Detalhes bibliográficos
Autor(a) principal: Vieira, Camilla Ivini Viana [UNESP]
Data de Publicação: 2017
Outros Autores: Reis, José Maurício Dos Santos Nunes [UNESP], Vaz, Luiz Geraldo [UNESP], Martins, Lídia Parsekian [UNESP], Martins, Renato Parsekian [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/2177-6709.22.1.038-046.oar
http://hdl.handle.net/11449/178843
Resumo: Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100% to 1000% of the effective length of the nickel-titanium portion present at the spring, at 37 °C. Deactivation data were plotted and deformation was found graphically. The values were compared by analysis of variance and Tukey’s post-hoc test. Results: Springs manufactured by Morelli had the same amount of deformation when they were activated up to 700% of Y activation; springs by Orthometric had the same amount of deformation up to 600-700% of Y; springs by Ormco had the same amount of deformation up to 700-800% of Y; and finally, the majority of springs by GAC had similar deformation up to 800%-1000% of activation. All springs tested could be activated up to 700% without rupture. Conclusions: Most subgroups were similarly deformed up to 700% of activation, without rupture of springs. Subgroups 4B, 4C, 4D and 4E showed the same amount of deformation up to 1000% of activation without any rupture at all.
id UNSP_d8bff6e0ac6194bc285693a766767a72
oai_identifier_str oai:repositorio.unesp.br:11449/178843
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Deformation of nickel-titanium closed coil springs: An in vitro studyBiomechanicsDeformationNiTiObjective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100% to 1000% of the effective length of the nickel-titanium portion present at the spring, at 37 °C. Deactivation data were plotted and deformation was found graphically. The values were compared by analysis of variance and Tukey’s post-hoc test. Results: Springs manufactured by Morelli had the same amount of deformation when they were activated up to 700% of Y activation; springs by Orthometric had the same amount of deformation up to 600-700% of Y; springs by Ormco had the same amount of deformation up to 700-800% of Y; and finally, the majority of springs by GAC had similar deformation up to 800%-1000% of activation. All springs tested could be activated up to 700% without rupture. Conclusions: Most subgroups were similarly deformed up to 700% of activation, without rupture of springs. Subgroups 4B, 4C, 4D and 4E showed the same amount of deformation up to 1000% of activation without any rupture at all.Universidade Estadual Paulista (UNESP) Department of Dental Material School of DentistryUniversidade Estadual Paulista (UNESP) Department of Dental Material School of DentistryUniversidade Estadual Paulista (Unesp)Vieira, Camilla Ivini Viana [UNESP]Reis, José Maurício Dos Santos Nunes [UNESP]Vaz, Luiz Geraldo [UNESP]Martins, Lídia Parsekian [UNESP]Martins, Renato Parsekian [UNESP]2018-12-11T17:32:22Z2018-12-11T17:32:22Z2017-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article38-46application/pdfhttp://dx.doi.org/10.1590/2177-6709.22.1.038-046.oarDental Press Journal of Orthodontics, v. 22, n. 1, p. 38-46, 2017.2177-67092176-9451http://hdl.handle.net/11449/17884310.1590/2177-6709.22.1.038-046.oarS2176-945120170001000382-s2.0-85018716803S2176-94512017000100038.pdf8223795731605246Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengDental Press Journal of Orthodontics0,4890,489info:eu-repo/semantics/openAccess2024-09-26T14:21:25Zoai:repositorio.unesp.br:11449/178843Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-26T14:21:25Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Deformation of nickel-titanium closed coil springs: An in vitro study
title Deformation of nickel-titanium closed coil springs: An in vitro study
spellingShingle Deformation of nickel-titanium closed coil springs: An in vitro study
Vieira, Camilla Ivini Viana [UNESP]
Biomechanics
Deformation
NiTi
title_short Deformation of nickel-titanium closed coil springs: An in vitro study
title_full Deformation of nickel-titanium closed coil springs: An in vitro study
title_fullStr Deformation of nickel-titanium closed coil springs: An in vitro study
title_full_unstemmed Deformation of nickel-titanium closed coil springs: An in vitro study
title_sort Deformation of nickel-titanium closed coil springs: An in vitro study
author Vieira, Camilla Ivini Viana [UNESP]
author_facet Vieira, Camilla Ivini Viana [UNESP]
Reis, José Maurício Dos Santos Nunes [UNESP]
Vaz, Luiz Geraldo [UNESP]
Martins, Lídia Parsekian [UNESP]
Martins, Renato Parsekian [UNESP]
author_role author
author2 Reis, José Maurício Dos Santos Nunes [UNESP]
Vaz, Luiz Geraldo [UNESP]
Martins, Lídia Parsekian [UNESP]
Martins, Renato Parsekian [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Vieira, Camilla Ivini Viana [UNESP]
Reis, José Maurício Dos Santos Nunes [UNESP]
Vaz, Luiz Geraldo [UNESP]
Martins, Lídia Parsekian [UNESP]
Martins, Renato Parsekian [UNESP]
dc.subject.por.fl_str_mv Biomechanics
Deformation
NiTi
topic Biomechanics
Deformation
NiTi
description Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100% to 1000% of the effective length of the nickel-titanium portion present at the spring, at 37 °C. Deactivation data were plotted and deformation was found graphically. The values were compared by analysis of variance and Tukey’s post-hoc test. Results: Springs manufactured by Morelli had the same amount of deformation when they were activated up to 700% of Y activation; springs by Orthometric had the same amount of deformation up to 600-700% of Y; springs by Ormco had the same amount of deformation up to 700-800% of Y; and finally, the majority of springs by GAC had similar deformation up to 800%-1000% of activation. All springs tested could be activated up to 700% without rupture. Conclusions: Most subgroups were similarly deformed up to 700% of activation, without rupture of springs. Subgroups 4B, 4C, 4D and 4E showed the same amount of deformation up to 1000% of activation without any rupture at all.
publishDate 2017
dc.date.none.fl_str_mv 2017-01-01
2018-12-11T17:32:22Z
2018-12-11T17:32:22Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/2177-6709.22.1.038-046.oar
Dental Press Journal of Orthodontics, v. 22, n. 1, p. 38-46, 2017.
2177-6709
2176-9451
http://hdl.handle.net/11449/178843
10.1590/2177-6709.22.1.038-046.oar
S2176-94512017000100038
2-s2.0-85018716803
S2176-94512017000100038.pdf
8223795731605246
url http://dx.doi.org/10.1590/2177-6709.22.1.038-046.oar
http://hdl.handle.net/11449/178843
identifier_str_mv Dental Press Journal of Orthodontics, v. 22, n. 1, p. 38-46, 2017.
2177-6709
2176-9451
10.1590/2177-6709.22.1.038-046.oar
S2176-94512017000100038
2-s2.0-85018716803
S2176-94512017000100038.pdf
8223795731605246
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Dental Press Journal of Orthodontics
0,489
0,489
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 38-46
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546421763178496