Enhancement of Breast Periphery Region in Digital Mammography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1117/12.2293547 http://hdl.handle.net/11449/164304 |
Resumo: | Volumetric breast density has been shown to be one of the strongest risk factor for breast cancer diagnosis. This metric can be estimated using digital mammograms. During mammography acquisition, breast is compressed and part of it loses contact with the paddle, resulting in an uncompressed region in periphery with thickness variation. Therefore, reliable density estimation in the breast periphery region is a problem, which affects the accuracy of volumetric breast density measurement. The aim of this study was to enhance breast periphery to solve the problem of thickness variation. Herein, we present an automatic algorithm to correct breast periphery thickness without changing pixel value from internal breast region. The correction pixel values from periphery was based on mean values over iso-distance lines from the breast skin-line using only adipose tissue information. The algorithm detects automatically the periphery region where thickness should be corrected. A correction factor was applied in breast periphery image to enhance the region. We also compare our contribution with two other algorithms from state-of-the-art, and we show its accuracy by means of different quality measures. Experienced radiologists subjectively evaluated resulting images from the tree methods in relation to original mammogram. The mean pixel value, skewness and kurtosis from histogram of the three methods were used as comparison metric. As a result, the methodology presented herein showed to be a good approach to be performed before calculating volumetric breast density. |
id |
UNSP_d9100613aa628ae3fabc855f9a4b2512 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/164304 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Enhancement of Breast Periphery Region in Digital MammographyMammographyperipheral enhancementthickness correctionimage processingVolumetric breast density has been shown to be one of the strongest risk factor for breast cancer diagnosis. This metric can be estimated using digital mammograms. During mammography acquisition, breast is compressed and part of it loses contact with the paddle, resulting in an uncompressed region in periphery with thickness variation. Therefore, reliable density estimation in the breast periphery region is a problem, which affects the accuracy of volumetric breast density measurement. The aim of this study was to enhance breast periphery to solve the problem of thickness variation. Herein, we present an automatic algorithm to correct breast periphery thickness without changing pixel value from internal breast region. The correction pixel values from periphery was based on mean values over iso-distance lines from the breast skin-line using only adipose tissue information. The algorithm detects automatically the periphery region where thickness should be corrected. A correction factor was applied in breast periphery image to enhance the region. We also compare our contribution with two other algorithms from state-of-the-art, and we show its accuracy by means of different quality measures. Experienced radiologists subjectively evaluated resulting images from the tree methods in relation to original mammogram. The mean pixel value, skewness and kurtosis from histogram of the three methods were used as comparison metric. As a result, the methodology presented herein showed to be a good approach to be performed before calculating volumetric breast density.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)project INCT-FNASao Paulo State Univ, Biosci Inst Botucatu, Dept Phys & Biophys, Dist Rubiao Jr S-N, BR-18618000 Sao Paulo, BrazilUniv Clermont Auvergne, Dept Inst Pascal, UMR UCA SIGMA CNRS 6602, F-63171 Aubiere, FranceUniv Estadual Paulista, Botucatu Med Sch, Dept Trop Dis & Diagnost Imaging, Dist Rubiao Jr S-N, BR-18618000 Sao Paulo, BrazilSao Paulo State Univ, Biosci Inst Botucatu, Dept Phys & Biophys, Dist Rubiao Jr S-N, BR-18618000 Sao Paulo, BrazilUniv Estadual Paulista, Botucatu Med Sch, Dept Trop Dis & Diagnost Imaging, Dist Rubiao Jr S-N, BR-18618000 Sao Paulo, BrazilCNPq: 88881.132793/2016-01CAPES: 88881.132793/2016-01project INCT-FNA: 464898/2014-5Spie-int Soc Optical EngineeringUniversidade Estadual Paulista (Unesp)Univ Clermont AuvergneMenegatti Pavan, Ana Luiza [UNESP]Vacavant, AntoineTrindade, Andre Petean [UNESP]Quini, Caio Cesar [UNESP]Pina, Diana Rodrigues de [UNESP]Angelini, E. D.Landman, B. A.2018-11-26T17:52:03Z2018-11-26T17:52:03Z2018-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject10application/pdfhttp://dx.doi.org/10.1117/12.2293547Medical Imaging 2018: Image Processing. Bellingham: Spie-int Soc Optical Engineering, v. 10574, 10 p., 2018.0277-786Xhttp://hdl.handle.net/11449/16430410.1117/12.2293547WOS:000435027500094WOS000435027500094.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengMedical Imaging 2018: Image Processinginfo:eu-repo/semantics/openAccess2024-08-15T15:23:39Zoai:repositorio.unesp.br:11449/164304Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-15T15:23:39Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Enhancement of Breast Periphery Region in Digital Mammography |
title |
Enhancement of Breast Periphery Region in Digital Mammography |
spellingShingle |
Enhancement of Breast Periphery Region in Digital Mammography Menegatti Pavan, Ana Luiza [UNESP] Mammography peripheral enhancement thickness correction image processing |
title_short |
Enhancement of Breast Periphery Region in Digital Mammography |
title_full |
Enhancement of Breast Periphery Region in Digital Mammography |
title_fullStr |
Enhancement of Breast Periphery Region in Digital Mammography |
title_full_unstemmed |
Enhancement of Breast Periphery Region in Digital Mammography |
title_sort |
Enhancement of Breast Periphery Region in Digital Mammography |
author |
Menegatti Pavan, Ana Luiza [UNESP] |
author_facet |
Menegatti Pavan, Ana Luiza [UNESP] Vacavant, Antoine Trindade, Andre Petean [UNESP] Quini, Caio Cesar [UNESP] Pina, Diana Rodrigues de [UNESP] Angelini, E. D. Landman, B. A. |
author_role |
author |
author2 |
Vacavant, Antoine Trindade, Andre Petean [UNESP] Quini, Caio Cesar [UNESP] Pina, Diana Rodrigues de [UNESP] Angelini, E. D. Landman, B. A. |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Univ Clermont Auvergne |
dc.contributor.author.fl_str_mv |
Menegatti Pavan, Ana Luiza [UNESP] Vacavant, Antoine Trindade, Andre Petean [UNESP] Quini, Caio Cesar [UNESP] Pina, Diana Rodrigues de [UNESP] Angelini, E. D. Landman, B. A. |
dc.subject.por.fl_str_mv |
Mammography peripheral enhancement thickness correction image processing |
topic |
Mammography peripheral enhancement thickness correction image processing |
description |
Volumetric breast density has been shown to be one of the strongest risk factor for breast cancer diagnosis. This metric can be estimated using digital mammograms. During mammography acquisition, breast is compressed and part of it loses contact with the paddle, resulting in an uncompressed region in periphery with thickness variation. Therefore, reliable density estimation in the breast periphery region is a problem, which affects the accuracy of volumetric breast density measurement. The aim of this study was to enhance breast periphery to solve the problem of thickness variation. Herein, we present an automatic algorithm to correct breast periphery thickness without changing pixel value from internal breast region. The correction pixel values from periphery was based on mean values over iso-distance lines from the breast skin-line using only adipose tissue information. The algorithm detects automatically the periphery region where thickness should be corrected. A correction factor was applied in breast periphery image to enhance the region. We also compare our contribution with two other algorithms from state-of-the-art, and we show its accuracy by means of different quality measures. Experienced radiologists subjectively evaluated resulting images from the tree methods in relation to original mammogram. The mean pixel value, skewness and kurtosis from histogram of the three methods were used as comparison metric. As a result, the methodology presented herein showed to be a good approach to be performed before calculating volumetric breast density. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-11-26T17:52:03Z 2018-11-26T17:52:03Z 2018-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1117/12.2293547 Medical Imaging 2018: Image Processing. Bellingham: Spie-int Soc Optical Engineering, v. 10574, 10 p., 2018. 0277-786X http://hdl.handle.net/11449/164304 10.1117/12.2293547 WOS:000435027500094 WOS000435027500094.pdf |
url |
http://dx.doi.org/10.1117/12.2293547 http://hdl.handle.net/11449/164304 |
identifier_str_mv |
Medical Imaging 2018: Image Processing. Bellingham: Spie-int Soc Optical Engineering, v. 10574, 10 p., 2018. 0277-786X 10.1117/12.2293547 WOS:000435027500094 WOS000435027500094.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Medical Imaging 2018: Image Processing |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
10 application/pdf |
dc.publisher.none.fl_str_mv |
Spie-int Soc Optical Engineering |
publisher.none.fl_str_mv |
Spie-int Soc Optical Engineering |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128135548370944 |