The impact of fuse link manufacturers on arc flash energy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1109/ESW.2011.6164724 http://hdl.handle.net/11449/72845 |
Resumo: | The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE. |
id |
UNSP_d93bdd0aa34ba812f5d66dd7645f0825 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/72845 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
The impact of fuse link manufacturers on arc flash energyArc flashFuse linksHazard controlArc FlashArc flash energiesArc flash hazardsArc hazardsElectrical installationsFuse arcFuse-linkIncident energyInterruption performanceSoftware programHazardsIndustrial plantsManagersManufactureArc lampsThe traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE.Du Pont Do Brasil S. A. L.A. Corporate EngineeringUniversity of São Paulo Polytechnic SchoolUNESP-Ilha SolteiraUNESP-Ilha SolteiraL.A. Corporate EngineeringUniversidade de São Paulo (USP)Universidade Estadual Paulista (Unesp)Leite, Fábio CorreaGrimoni, Jose Aquiles B.Malheiro, Fábio Mendes [UNESP]Tomiyoshi, Luiz Kazunori2014-05-27T11:26:14Z2014-05-27T11:26:14Z2011-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjecthttp://dx.doi.org/10.1109/ESW.2011.6164724Conference Record of the 2011 IEEE IAS Electrical Safety Workshop, ESW 2011.http://hdl.handle.net/11449/7284510.1109/ESW.2011.61647242-s2.0-84859042267Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengConference Record of the 2011 IEEE IAS Electrical Safety Workshop, ESW 2011info:eu-repo/semantics/openAccess2021-10-23T21:37:45Zoai:repositorio.unesp.br:11449/72845Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:51:36.104617Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
The impact of fuse link manufacturers on arc flash energy |
title |
The impact of fuse link manufacturers on arc flash energy |
spellingShingle |
The impact of fuse link manufacturers on arc flash energy Leite, Fábio Correa Arc flash Fuse links Hazard control Arc Flash Arc flash energies Arc flash hazards Arc hazards Electrical installations Fuse arc Fuse-link Incident energy Interruption performance Software program Hazards Industrial plants Managers Manufacture Arc lamps |
title_short |
The impact of fuse link manufacturers on arc flash energy |
title_full |
The impact of fuse link manufacturers on arc flash energy |
title_fullStr |
The impact of fuse link manufacturers on arc flash energy |
title_full_unstemmed |
The impact of fuse link manufacturers on arc flash energy |
title_sort |
The impact of fuse link manufacturers on arc flash energy |
author |
Leite, Fábio Correa |
author_facet |
Leite, Fábio Correa Grimoni, Jose Aquiles B. Malheiro, Fábio Mendes [UNESP] Tomiyoshi, Luiz Kazunori |
author_role |
author |
author2 |
Grimoni, Jose Aquiles B. Malheiro, Fábio Mendes [UNESP] Tomiyoshi, Luiz Kazunori |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
L.A. Corporate Engineering Universidade de São Paulo (USP) Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Leite, Fábio Correa Grimoni, Jose Aquiles B. Malheiro, Fábio Mendes [UNESP] Tomiyoshi, Luiz Kazunori |
dc.subject.por.fl_str_mv |
Arc flash Fuse links Hazard control Arc Flash Arc flash energies Arc flash hazards Arc hazards Electrical installations Fuse arc Fuse-link Incident energy Interruption performance Software program Hazards Industrial plants Managers Manufacture Arc lamps |
topic |
Arc flash Fuse links Hazard control Arc Flash Arc flash energies Arc flash hazards Arc hazards Electrical installations Fuse arc Fuse-link Incident energy Interruption performance Software program Hazards Industrial plants Managers Manufacture Arc lamps |
description |
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-12-01 2014-05-27T11:26:14Z 2014-05-27T11:26:14Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1109/ESW.2011.6164724 Conference Record of the 2011 IEEE IAS Electrical Safety Workshop, ESW 2011. http://hdl.handle.net/11449/72845 10.1109/ESW.2011.6164724 2-s2.0-84859042267 |
url |
http://dx.doi.org/10.1109/ESW.2011.6164724 http://hdl.handle.net/11449/72845 |
identifier_str_mv |
Conference Record of the 2011 IEEE IAS Electrical Safety Workshop, ESW 2011. 10.1109/ESW.2011.6164724 2-s2.0-84859042267 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Conference Record of the 2011 IEEE IAS Electrical Safety Workshop, ESW 2011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129129509289984 |