Resumo: | This paper proposes a method to solve the fault section estimation (FSE) problem in power systems by developing a nonlinear binary programming model using the AMPL mathematical programming language. This model is developed based on the minimum set covering problem that contemplates the philosophy and logic of the protection system employed by electrical power companies and associates the alarms of the protective relays reported by the SCADA system with the expected states of the protective relays' functions. The proposed method was evaluated using a benchmark test system found in the related literature and the results show its efficiency, correct diagnosis, computational robustness, with the advantage of not needing to calibrate any control parameter or training in order to solve the fault section estimation problem in power systems. |
id |
UNSP_da182d53c16b8b95ef0d3db5207b7024 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/164005 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power SystemsFault diagnosisFault section estimationPower Systems ProtectionProtective RelayingThis paper proposes a method to solve the fault section estimation (FSE) problem in power systems by developing a nonlinear binary programming model using the AMPL mathematical programming language. This model is developed based on the minimum set covering problem that contemplates the philosophy and logic of the protection system employed by electrical power companies and associates the alarms of the protective relays reported by the SCADA system with the expected states of the protective relays' functions. The proposed method was evaluated using a benchmark test system found in the related literature and the results show its efficiency, correct diagnosis, computational robustness, with the advantage of not needing to calibrate any control parameter or training in order to solve the fault section estimation problem in power systems.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Sao Paulo State Univ, Dept Elect Engn, FEIS, Ilha Solteira, BrazilSao Paulo State Univ UNESP, Res Grp Elect Power Syst Planning, Dept Elect Engn, Engn Coll Ilha Solteira, POB 31, BR-15385000 Ilha Solteira, SP, BrazilSao Paulo State Univ, Dept Elect Engn, FEIS, Ilha Solteira, BrazilSao Paulo State Univ UNESP, Res Grp Elect Power Syst Planning, Dept Elect Engn, Engn Coll Ilha Solteira, POB 31, BR-15385000 Ilha Solteira, SP, BrazilCNPq: 142046/2016-7FAPESP: 2006/02569-7IeeeUniversidade Estadual Paulista (Unesp)Figueroa Escoto, Esau [UNESP]Leao, Fabio Bertequini [UNESP]IEEE2018-11-26T17:48:44Z2018-11-26T17:48:44Z2017-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject62017 Ieee International Autumn Meeting On Power, Electronics And Computing (ropec). New York: Ieee, 6 p., 2017.2381-5515http://hdl.handle.net/11449/164005WOS:000427915800053Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPeng2017 Ieee International Autumn Meeting On Power, Electronics And Computing (ropec)info:eu-repo/semantics/openAccess2024-07-04T19:11:38Zoai:repositorio.unesp.br:11449/164005Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T18:09:00.044222Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power Systems |
title |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power Systems |
spellingShingle |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power Systems Figueroa Escoto, Esau [UNESP] Fault diagnosis Fault section estimation Power Systems Protection Protective Relaying |
title_short |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power Systems |
title_full |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power Systems |
title_fullStr |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power Systems |
title_full_unstemmed |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power Systems |
title_sort |
A Nonlinear Binary Programming Model for Fault Section Estimation in Electric Power Systems |
author |
Figueroa Escoto, Esau [UNESP] |
author_facet |
Figueroa Escoto, Esau [UNESP] Leao, Fabio Bertequini [UNESP] IEEE |
author_role |
author |
author2 |
Leao, Fabio Bertequini [UNESP] IEEE |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Figueroa Escoto, Esau [UNESP] Leao, Fabio Bertequini [UNESP] IEEE |
dc.subject.por.fl_str_mv |
Fault diagnosis Fault section estimation Power Systems Protection Protective Relaying |
topic |
Fault diagnosis Fault section estimation Power Systems Protection Protective Relaying |
description |
This paper proposes a method to solve the fault section estimation (FSE) problem in power systems by developing a nonlinear binary programming model using the AMPL mathematical programming language. This model is developed based on the minimum set covering problem that contemplates the philosophy and logic of the protection system employed by electrical power companies and associates the alarms of the protective relays reported by the SCADA system with the expected states of the protective relays' functions. The proposed method was evaluated using a benchmark test system found in the related literature and the results show its efficiency, correct diagnosis, computational robustness, with the advantage of not needing to calibrate any control parameter or training in order to solve the fault section estimation problem in power systems. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-01-01 2018-11-26T17:48:44Z 2018-11-26T17:48:44Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
2017 Ieee International Autumn Meeting On Power, Electronics And Computing (ropec). New York: Ieee, 6 p., 2017. 2381-5515 http://hdl.handle.net/11449/164005 WOS:000427915800053 |
identifier_str_mv |
2017 Ieee International Autumn Meeting On Power, Electronics And Computing (ropec). New York: Ieee, 6 p., 2017. 2381-5515 WOS:000427915800053 |
url |
http://hdl.handle.net/11449/164005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2017 Ieee International Autumn Meeting On Power, Electronics And Computing (ropec) |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
6 |
dc.publisher.none.fl_str_mv |
Ieee |
publisher.none.fl_str_mv |
Ieee |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128902462177280 |