Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1109/PESMG.2013.6672821 http://hdl.handle.net/11449/112119 |
Resumo: | Usually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system. |
id |
UNSP_dafa5a18217f4721deaed534713dee9e |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/112119 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed GeneratorsConventional generatorsdistributed generatorsactive power reserve for frequency controlcosts minimizationUsually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system.Univ Estadual Paulista, UNESP, Ilha Solteira, SP, BrazilUniv Estadual Paulista, UNESP, Ilha Solteira, SP, BrazilIeeeUniversidade Estadual Paulista (Unesp)Rueda-Medina, Augusto C. [UNESP]Padilha-Feltrin, Antonio [UNESP]Mantovani, J. R. S. [UNESP]IEEE2014-12-03T13:09:15Z2014-12-03T13:09:15Z2013-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject5http://dx.doi.org/10.1109/PESMG.2013.66728212013 IEEE Power and Energy Society General Meeting (pes). New York: IEEE, 5 p., 2013.1944-9925http://hdl.handle.net/11449/112119WOS:0003318743030080614021283361265Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPeng2013 IEEE Power And Energy Society General Meeting (pes)0,328info:eu-repo/semantics/openAccess2024-07-04T19:11:49Zoai:repositorio.unesp.br:11449/112119Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T21:29:33.055683Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators |
title |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators |
spellingShingle |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators Rueda-Medina, Augusto C. [UNESP] Conventional generators distributed generators active power reserve for frequency control costs minimization |
title_short |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators |
title_full |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators |
title_fullStr |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators |
title_full_unstemmed |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators |
title_sort |
Capacity of Active Power Reserve for Frequency Control Enhanced by Distributed Generators |
author |
Rueda-Medina, Augusto C. [UNESP] |
author_facet |
Rueda-Medina, Augusto C. [UNESP] Padilha-Feltrin, Antonio [UNESP] Mantovani, J. R. S. [UNESP] IEEE |
author_role |
author |
author2 |
Padilha-Feltrin, Antonio [UNESP] Mantovani, J. R. S. [UNESP] IEEE |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Rueda-Medina, Augusto C. [UNESP] Padilha-Feltrin, Antonio [UNESP] Mantovani, J. R. S. [UNESP] IEEE |
dc.subject.por.fl_str_mv |
Conventional generators distributed generators active power reserve for frequency control costs minimization |
topic |
Conventional generators distributed generators active power reserve for frequency control costs minimization |
description |
Usually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-01-01 2014-12-03T13:09:15Z 2014-12-03T13:09:15Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1109/PESMG.2013.6672821 2013 IEEE Power and Energy Society General Meeting (pes). New York: IEEE, 5 p., 2013. 1944-9925 http://hdl.handle.net/11449/112119 WOS:000331874303008 0614021283361265 |
url |
http://dx.doi.org/10.1109/PESMG.2013.6672821 http://hdl.handle.net/11449/112119 |
identifier_str_mv |
2013 IEEE Power and Energy Society General Meeting (pes). New York: IEEE, 5 p., 2013. 1944-9925 WOS:000331874303008 0614021283361265 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2013 IEEE Power And Energy Society General Meeting (pes) 0,328 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
5 |
dc.publisher.none.fl_str_mv |
Ieee |
publisher.none.fl_str_mv |
Ieee |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129325798522880 |