Resumo: | This paper proposes a methodology to model and control a three phase voltage source inverter (VSI) with LCL filter intended for distributed generation in microgrid scenario. Thus, the inverter should be able to operate in both grid connected and islanded modes with a smooth transition between them. The strategy is to split the control input into two components. The first component is generated to make the voltages at capacitors to track sinusoidal references; meanwhile the second component is suitable to increase these voltages in order to achieve the certain amplitude and phase that guarantee the required output current. To obtain the controllers that generate these control signals, system is modeled in state-space and reduced to an equivalent single phase representation; state feedback controllers are computed by means of Linear Matrix Inequalities solvers considering uncertainty on the grid inductance. Simulation results prove the validity of the proposed control system. |
id |
UNSP_de744bb9d58b7a7588e7b6c68fdb0553 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/161684 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviromentGrid-connected inverterLCL filterLinear Matrix Inequalities (LMIs)Microgrid inverterRobust controlThis paper proposes a methodology to model and control a three phase voltage source inverter (VSI) with LCL filter intended for distributed generation in microgrid scenario. Thus, the inverter should be able to operate in both grid connected and islanded modes with a smooth transition between them. The strategy is to split the control input into two components. The first component is generated to make the voltages at capacitors to track sinusoidal references; meanwhile the second component is suitable to increase these voltages in order to achieve the certain amplitude and phase that guarantee the required output current. To obtain the controllers that generate these control signals, system is modeled in state-space and reduced to an equivalent single phase representation; state feedback controllers are computed by means of Linear Matrix Inequalities solvers considering uncertainty on the grid inductance. Simulation results prove the validity of the proposed control system.Sao Paulo State Univ UNESP, Power Elect Lab, Ilha Solteira, SP, BrazilFed Technol Univ Parana UTFPR, Dept Elect Engn, Cornelio Procopio, PR, BrazilSao Paulo State Univ UNESP, Power Elect Lab, Ilha Solteira, SP, BrazilIeeeUniversidade Estadual Paulista (Unesp)Fed Technol Univ Parana UTFPRPena, Jose Carlos U. [UNESP]Canesin, Carlos A. [UNESP]Sampaio, Leonardo P.IEEE2018-11-26T16:48:14Z2018-11-26T16:48:14Z2015-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject1617-16232015 Ieee Energy Conversion Congress And Exposition (ecce). New York: Ieee, p. 1617-1623, 2015.2329-3721http://hdl.handle.net/11449/161684WOS:000378882901137Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPeng2015 Ieee Energy Conversion Congress And Exposition (ecce)info:eu-repo/semantics/openAccess2024-07-04T19:11:32Zoai:repositorio.unesp.br:11449/161684Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T16:54:59.275510Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment |
title |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment |
spellingShingle |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment Pena, Jose Carlos U. [UNESP] Grid-connected inverter LCL filter Linear Matrix Inequalities (LMIs) Microgrid inverter Robust control |
title_short |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment |
title_full |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment |
title_fullStr |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment |
title_full_unstemmed |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment |
title_sort |
Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment |
author |
Pena, Jose Carlos U. [UNESP] |
author_facet |
Pena, Jose Carlos U. [UNESP] Canesin, Carlos A. [UNESP] Sampaio, Leonardo P. IEEE |
author_role |
author |
author2 |
Canesin, Carlos A. [UNESP] Sampaio, Leonardo P. IEEE |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Fed Technol Univ Parana UTFPR |
dc.contributor.author.fl_str_mv |
Pena, Jose Carlos U. [UNESP] Canesin, Carlos A. [UNESP] Sampaio, Leonardo P. IEEE |
dc.subject.por.fl_str_mv |
Grid-connected inverter LCL filter Linear Matrix Inequalities (LMIs) Microgrid inverter Robust control |
topic |
Grid-connected inverter LCL filter Linear Matrix Inequalities (LMIs) Microgrid inverter Robust control |
description |
This paper proposes a methodology to model and control a three phase voltage source inverter (VSI) with LCL filter intended for distributed generation in microgrid scenario. Thus, the inverter should be able to operate in both grid connected and islanded modes with a smooth transition between them. The strategy is to split the control input into two components. The first component is generated to make the voltages at capacitors to track sinusoidal references; meanwhile the second component is suitable to increase these voltages in order to achieve the certain amplitude and phase that guarantee the required output current. To obtain the controllers that generate these control signals, system is modeled in state-space and reduced to an equivalent single phase representation; state feedback controllers are computed by means of Linear Matrix Inequalities solvers considering uncertainty on the grid inductance. Simulation results prove the validity of the proposed control system. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-01-01 2018-11-26T16:48:14Z 2018-11-26T16:48:14Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
2015 Ieee Energy Conversion Congress And Exposition (ecce). New York: Ieee, p. 1617-1623, 2015. 2329-3721 http://hdl.handle.net/11449/161684 WOS:000378882901137 |
identifier_str_mv |
2015 Ieee Energy Conversion Congress And Exposition (ecce). New York: Ieee, p. 1617-1623, 2015. 2329-3721 WOS:000378882901137 |
url |
http://hdl.handle.net/11449/161684 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2015 Ieee Energy Conversion Congress And Exposition (ecce) |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1617-1623 |
dc.publisher.none.fl_str_mv |
Ieee |
publisher.none.fl_str_mv |
Ieee |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128720429383680 |