Anaerobic capacity may not be determined by critical power model in elite table tennis players

Detalhes bibliográficos
Autor(a) principal: Zagatto, Alessandro M.
Data de Publicação: 2008
Outros Autores: Papoti, Marcelo, Gobatto, Claudio A. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.jssm.org/vol7/n1/8/v7n1-8text.php
http://hdl.handle.net/11449/20777
Resumo: The aim of the present study was to verify the applicability of anaerobic work capacity (AWC) determined from the critical power model in elite table tennis players. Eight male international level table tennis players participated in the study. The tests undertaken were: 1) A critical frequency test used to determinate the anaerobic work capacity; 2) Wingate tests were performed using leg and arm ergometers. AWC corresponded to 99.5 +/- 29.1 table tennis balls. AWC was not related to peak (r = -0.25), mean (r = -0.02), relative peak (r = -0.49) or relative mean power (r = 0.01), nor fatigue index (r = -0.52) (Wingate leg ergometer). Similar correlations for peak (r = -0.34), mean (r = -0.04), relative peak (r = -0.49), relative mean power (r = -0.14) and peak blood lactate concentration (r = -0.08) were determined in the Wingate arm ergometer test. Based on these results the AWC determined by a modified critical power test was not a good index for measurement of anaerobic capacity in table tennis players.
id UNSP_e0287a204a1de89fbd49e68cfa83bd74
oai_identifier_str oai:repositorio.unesp.br:11449/20777
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Anaerobic capacity may not be determined by critical power model in elite table tennis playersanaerobic capacitytable tenniscritical frequencyWingate testlactateThe aim of the present study was to verify the applicability of anaerobic work capacity (AWC) determined from the critical power model in elite table tennis players. Eight male international level table tennis players participated in the study. The tests undertaken were: 1) A critical frequency test used to determinate the anaerobic work capacity; 2) Wingate tests were performed using leg and arm ergometers. AWC corresponded to 99.5 +/- 29.1 table tennis balls. AWC was not related to peak (r = -0.25), mean (r = -0.02), relative peak (r = -0.49) or relative mean power (r = 0.01), nor fatigue index (r = -0.52) (Wingate leg ergometer). Similar correlations for peak (r = -0.34), mean (r = -0.04), relative peak (r = -0.49), relative mean power (r = -0.14) and peak blood lactate concentration (r = -0.08) were determined in the Wingate arm ergometer test. Based on these results the AWC determined by a modified critical power test was not a good index for measurement of anaerobic capacity in table tennis players.Universidade Federal de Mato Grosso do Sul (UFMS), LAPEFE, Dept Phys Educ, Campo Grande, MS, BrazilUniv Integrated Bauru FIB, Dept Phys Educ, Bauru, SP, BrazilSão Paulo State Univ, IB, Lab Physiol Appl Sport, Dept Phys Educ, Rio Claro, BrazilSão Paulo State Univ, IB, Lab Physiol Appl Sport, Dept Phys Educ, Rio Claro, BrazilJournal Sports Science & MedicineUniversidade Federal de Mato Grosso do Sul (UFMS)Universidade de São Paulo (USP)Universidade Estadual Paulista (Unesp)Zagatto, Alessandro M.Papoti, MarceloGobatto, Claudio A. [UNESP]2013-09-30T18:48:48Z2014-05-20T13:58:29Z2013-09-30T18:48:48Z2014-05-20T13:58:29Z2008-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article54-59http://www.jssm.org/vol7/n1/8/v7n1-8text.phpJournal of Sports Science and Medicine. Bursa: Journal Sports Science & Medicine, v. 7, n. 1, p. 54-59, 2008.1303-2968http://hdl.handle.net/11449/20777WOS:000253782800008Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Sports Science and Medicine1.9901,091info:eu-repo/semantics/openAccess2021-10-23T19:02:03Zoai:repositorio.unesp.br:11449/20777Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T16:34:01.830972Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Anaerobic capacity may not be determined by critical power model in elite table tennis players
title Anaerobic capacity may not be determined by critical power model in elite table tennis players
spellingShingle Anaerobic capacity may not be determined by critical power model in elite table tennis players
Zagatto, Alessandro M.
anaerobic capacity
table tennis
critical frequency
Wingate test
lactate
title_short Anaerobic capacity may not be determined by critical power model in elite table tennis players
title_full Anaerobic capacity may not be determined by critical power model in elite table tennis players
title_fullStr Anaerobic capacity may not be determined by critical power model in elite table tennis players
title_full_unstemmed Anaerobic capacity may not be determined by critical power model in elite table tennis players
title_sort Anaerobic capacity may not be determined by critical power model in elite table tennis players
author Zagatto, Alessandro M.
author_facet Zagatto, Alessandro M.
Papoti, Marcelo
Gobatto, Claudio A. [UNESP]
author_role author
author2 Papoti, Marcelo
Gobatto, Claudio A. [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Federal de Mato Grosso do Sul (UFMS)
Universidade de São Paulo (USP)
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Zagatto, Alessandro M.
Papoti, Marcelo
Gobatto, Claudio A. [UNESP]
dc.subject.por.fl_str_mv anaerobic capacity
table tennis
critical frequency
Wingate test
lactate
topic anaerobic capacity
table tennis
critical frequency
Wingate test
lactate
description The aim of the present study was to verify the applicability of anaerobic work capacity (AWC) determined from the critical power model in elite table tennis players. Eight male international level table tennis players participated in the study. The tests undertaken were: 1) A critical frequency test used to determinate the anaerobic work capacity; 2) Wingate tests were performed using leg and arm ergometers. AWC corresponded to 99.5 +/- 29.1 table tennis balls. AWC was not related to peak (r = -0.25), mean (r = -0.02), relative peak (r = -0.49) or relative mean power (r = 0.01), nor fatigue index (r = -0.52) (Wingate leg ergometer). Similar correlations for peak (r = -0.34), mean (r = -0.04), relative peak (r = -0.49), relative mean power (r = -0.14) and peak blood lactate concentration (r = -0.08) were determined in the Wingate arm ergometer test. Based on these results the AWC determined by a modified critical power test was not a good index for measurement of anaerobic capacity in table tennis players.
publishDate 2008
dc.date.none.fl_str_mv 2008-03-01
2013-09-30T18:48:48Z
2013-09-30T18:48:48Z
2014-05-20T13:58:29Z
2014-05-20T13:58:29Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.jssm.org/vol7/n1/8/v7n1-8text.php
Journal of Sports Science and Medicine. Bursa: Journal Sports Science & Medicine, v. 7, n. 1, p. 54-59, 2008.
1303-2968
http://hdl.handle.net/11449/20777
WOS:000253782800008
url http://www.jssm.org/vol7/n1/8/v7n1-8text.php
http://hdl.handle.net/11449/20777
identifier_str_mv Journal of Sports Science and Medicine. Bursa: Journal Sports Science & Medicine, v. 7, n. 1, p. 54-59, 2008.
1303-2968
WOS:000253782800008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Sports Science and Medicine
1.990
1,091
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 54-59
dc.publisher.none.fl_str_mv Journal Sports Science & Medicine
publisher.none.fl_str_mv Journal Sports Science & Medicine
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128671391678464