Resumo: The increasingly design requirements for modern engineering applications resulted in the development of new materials with improved mechanical properties. Low density, combined with excellent weight/strength ratio as well as corrosion resistance, make the titanium attractive for application in landing gears. Fatigue control is a fundamental parameter to be considered in the development of mechanical components. The aim of this research is to analyze the fatigue behavior of anodized Ti-6Al-4V alloy and the influence of shot peening pre treatment on the experimental data. Axial fatigue tests (R = 0.1) were performed, and a significant reduction in the fatigue strength of anodized Ti-6Al-4V was observed. The shot peening superficial treatment, which objective is to create a compressive residual stress field in the surface layers, showed efficiency to increase the fatigue life of anodized material. Experimental data were represented by S-N curves. Scanning electron microscopy technique (SEM) was used to observe crack origin sites.
id UNSP_e2d98dca91014b76af2a0abee9b492c5
oai_identifier_str oai:repositorio.unesp.br:11449/30578
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloyfatigueanodizationtitaniumshot peeningThe increasingly design requirements for modern engineering applications resulted in the development of new materials with improved mechanical properties. Low density, combined with excellent weight/strength ratio as well as corrosion resistance, make the titanium attractive for application in landing gears. Fatigue control is a fundamental parameter to be considered in the development of mechanical components. The aim of this research is to analyze the fatigue behavior of anodized Ti-6Al-4V alloy and the influence of shot peening pre treatment on the experimental data. Axial fatigue tests (R = 0.1) were performed, and a significant reduction in the fatigue strength of anodized Ti-6Al-4V was observed. The shot peening superficial treatment, which objective is to create a compressive residual stress field in the surface layers, showed efficiency to increase the fatigue life of anodized material. Experimental data were represented by S-N curves. Scanning electron microscopy technique (SEM) was used to observe crack origin sites.State University of São Paulo Department of Materials and Technology Fatigue and aeronautical materials research groupEmbraer Liebherr Equipamentos do Brasil LtdaUNESP IPOLIUNESP IPOLIABM, ABC, ABPolEmbraer Liebherr Equipamentos do Brasil LtdaUniversidade Estadual Paulista (Unesp)Costa, Midori Yoshikawa PitangaVoorwald, Herman Jacobus Cornelis [UNESP]Pigatin, Walter LuisGuimarães, Valdir AlvesCioffi, Maria Odila Hilário [UNESP]2014-05-20T15:17:43Z2014-05-20T15:17:43Z2006-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article107-109application/pdfhttp://dx.doi.org/10.1590/S1516-14392006000100020Materials Research. ABM, ABC, ABPol, v. 9, n. 1, p. 107-109, 2006.1516-1439http://hdl.handle.net/11449/3057810.1590/S1516-14392006000100020S1516-14392006000100020S1516-14392006000100020.pdf35115347958057766119671014416126SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengMaterials Research1.1030,398info:eu-repo/semantics/openAccess2024-07-02T15:04:04Zoai:repositorio.unesp.br:11449/30578Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T20:20:14.149596Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy
title Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy
spellingShingle Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy
Costa, Midori Yoshikawa Pitanga
fatigue
anodization
titanium
shot peening
title_short Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy
title_full Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy
title_fullStr Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy
title_full_unstemmed Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy
title_sort Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy
author Costa, Midori Yoshikawa Pitanga
author_facet Costa, Midori Yoshikawa Pitanga
Voorwald, Herman Jacobus Cornelis [UNESP]
Pigatin, Walter Luis
Guimarães, Valdir Alves
Cioffi, Maria Odila Hilário [UNESP]
author_role author
author2 Voorwald, Herman Jacobus Cornelis [UNESP]
Pigatin, Walter Luis
Guimarães, Valdir Alves
Cioffi, Maria Odila Hilário [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Embraer Liebherr Equipamentos do Brasil Ltda
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Costa, Midori Yoshikawa Pitanga
Voorwald, Herman Jacobus Cornelis [UNESP]
Pigatin, Walter Luis
Guimarães, Valdir Alves
Cioffi, Maria Odila Hilário [UNESP]
dc.subject.por.fl_str_mv fatigue
anodization
titanium
shot peening
topic fatigue
anodization
titanium
shot peening
description The increasingly design requirements for modern engineering applications resulted in the development of new materials with improved mechanical properties. Low density, combined with excellent weight/strength ratio as well as corrosion resistance, make the titanium attractive for application in landing gears. Fatigue control is a fundamental parameter to be considered in the development of mechanical components. The aim of this research is to analyze the fatigue behavior of anodized Ti-6Al-4V alloy and the influence of shot peening pre treatment on the experimental data. Axial fatigue tests (R = 0.1) were performed, and a significant reduction in the fatigue strength of anodized Ti-6Al-4V was observed. The shot peening superficial treatment, which objective is to create a compressive residual stress field in the surface layers, showed efficiency to increase the fatigue life of anodized material. Experimental data were represented by S-N curves. Scanning electron microscopy technique (SEM) was used to observe crack origin sites.
publishDate 2006
dc.date.none.fl_str_mv 2006-03-01
2014-05-20T15:17:43Z
2014-05-20T15:17:43Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1516-14392006000100020
Materials Research. ABM, ABC, ABPol, v. 9, n. 1, p. 107-109, 2006.
1516-1439
http://hdl.handle.net/11449/30578
10.1590/S1516-14392006000100020
S1516-14392006000100020
S1516-14392006000100020.pdf
3511534795805776
6119671014416126
url http://dx.doi.org/10.1590/S1516-14392006000100020
http://hdl.handle.net/11449/30578
identifier_str_mv Materials Research. ABM, ABC, ABPol, v. 9, n. 1, p. 107-109, 2006.
1516-1439
10.1590/S1516-14392006000100020
S1516-14392006000100020
S1516-14392006000100020.pdf
3511534795805776
6119671014416126
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Materials Research
1.103
0,398
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 107-109
application/pdf
dc.publisher.none.fl_str_mv ABM, ABC, ABPol
publisher.none.fl_str_mv ABM, ABC, ABPol
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129190327746560