Design of the statistical control of low fraction nonconforming processes restricted to small samples
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/231046 |
Resumo: | We present the non-conventional design of no charts used for the surveillance of processes characterized by a very low fraction nonconforming, with a costly and/or time-consuming inspection procedure. which makes the inspection of large samples prohibitive. Under these circumstances, the trade-off between the false-alarm rate and the speed with which the chart signals process deteriorations is the basis to design the control chart, once [depending on the sample size) the conventional np chart with three-sigma limits offers little protection against false alarms or is slow in detecting process disturbances. The study was motivated by the real case of a newspapers packaging process. The nominal number of newspapers in the package depends on the newspaper's breadth, and packages with a number of newspapers different from nominal are considered nonconforming. |
id |
UNSP_e315d73d355a70acbbdf762f77142b3e |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/231046 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Design of the statistical control of low fraction nonconforming processes restricted to small samplesPlanejamento do controle estatístico de processos com baixa fração não conforme restrito a amostras pequenasControl by attributesDesign of control chartsNp chartsStatistical process controlWe present the non-conventional design of no charts used for the surveillance of processes characterized by a very low fraction nonconforming, with a costly and/or time-consuming inspection procedure. which makes the inspection of large samples prohibitive. Under these circumstances, the trade-off between the false-alarm rate and the speed with which the chart signals process deteriorations is the basis to design the control chart, once [depending on the sample size) the conventional np chart with three-sigma limits offers little protection against false alarms or is slow in detecting process disturbances. The study was motivated by the real case of a newspapers packaging process. The nominal number of newspapers in the package depends on the newspaper's breadth, and packages with a number of newspapers different from nominal are considered nonconforming.Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio), Rua Marques de São Vicente 225, 22453-900 Rio de Janeiro, RJDepartamento de Engenharia Industrial, Rua Marquies de Sao Vicente 225, 22453-900 Rio de Janeiro, RJUNESP Faculdade de Engenharia, Campus de Guaratinguetá, SPDepartamento de Produção, Av. Ariberto Pereira da Cunha 333, 12516-410 Guaratinguetá, SPUNESP Faculdade de Engenharia, Campus de Guaratinguetá, SPPontifícia Universidade Católica do Rio de Janeiro (PUC-Rio)Universidade Estadual Paulista (UNESP)Leiras, AdrianaEpprecht, Eugenio KahnCosta, Antonio Fernando Branco [UNESP]2022-04-29T08:43:21Z2022-04-29T08:43:21Z2007-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article139-150Producao, v. 17, n. 1, p. 139-150, 2007.1980-54110103-6513http://hdl.handle.net/11449/2310462-s2.0-34648837481Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporProducao28666info:eu-repo/semantics/openAccess2024-07-02T17:37:04Zoai:repositorio.unesp.br:11449/231046Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T14:39:17.283573Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Design of the statistical control of low fraction nonconforming processes restricted to small samples Planejamento do controle estatístico de processos com baixa fração não conforme restrito a amostras pequenas |
title |
Design of the statistical control of low fraction nonconforming processes restricted to small samples |
spellingShingle |
Design of the statistical control of low fraction nonconforming processes restricted to small samples Leiras, Adriana Control by attributes Design of control charts Np charts Statistical process control |
title_short |
Design of the statistical control of low fraction nonconforming processes restricted to small samples |
title_full |
Design of the statistical control of low fraction nonconforming processes restricted to small samples |
title_fullStr |
Design of the statistical control of low fraction nonconforming processes restricted to small samples |
title_full_unstemmed |
Design of the statistical control of low fraction nonconforming processes restricted to small samples |
title_sort |
Design of the statistical control of low fraction nonconforming processes restricted to small samples |
author |
Leiras, Adriana |
author_facet |
Leiras, Adriana Epprecht, Eugenio Kahn Costa, Antonio Fernando Branco [UNESP] |
author_role |
author |
author2 |
Epprecht, Eugenio Kahn Costa, Antonio Fernando Branco [UNESP] |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Leiras, Adriana Epprecht, Eugenio Kahn Costa, Antonio Fernando Branco [UNESP] |
dc.subject.por.fl_str_mv |
Control by attributes Design of control charts Np charts Statistical process control |
topic |
Control by attributes Design of control charts Np charts Statistical process control |
description |
We present the non-conventional design of no charts used for the surveillance of processes characterized by a very low fraction nonconforming, with a costly and/or time-consuming inspection procedure. which makes the inspection of large samples prohibitive. Under these circumstances, the trade-off between the false-alarm rate and the speed with which the chart signals process deteriorations is the basis to design the control chart, once [depending on the sample size) the conventional np chart with three-sigma limits offers little protection against false alarms or is slow in detecting process disturbances. The study was motivated by the real case of a newspapers packaging process. The nominal number of newspapers in the package depends on the newspaper's breadth, and packages with a number of newspapers different from nominal are considered nonconforming. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-01-01 2022-04-29T08:43:21Z 2022-04-29T08:43:21Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Producao, v. 17, n. 1, p. 139-150, 2007. 1980-5411 0103-6513 http://hdl.handle.net/11449/231046 2-s2.0-34648837481 |
identifier_str_mv |
Producao, v. 17, n. 1, p. 139-150, 2007. 1980-5411 0103-6513 2-s2.0-34648837481 |
url |
http://hdl.handle.net/11449/231046 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
Producao 28666 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
139-150 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128394872750080 |