Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating

Detalhes bibliográficos
Autor(a) principal: Sisti, Karin E.
Data de Publicação: 2013
Outros Autores: Piattelli, Adriano, Guastaldi, Antonio C. [UNESP], Queiroz, Thallita P., De Rossi, Rafael
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.11607/prd.1151
http://hdl.handle.net/11449/220241
Resumo: The purpose of this study was nondecalcified histologic analysis of titanium implants modified by laser with and without hydroxyapatite. Implants with three modified surfaces were inserted into rabbit tibias: group 1, machined surface; group 2, irradiated (laser); and group 3, irradiated and hydroxyapatite coated (biomimetic method). The mean surface roughness (Ra) scores of groups 2 and 3 were higher than that of group 1. Boneimplant contact measurements at 30 and 60 days for groups 2 and 3 were higher than for group 1. Bone area at 30 and 60 days for group 2 was higher than for groups 1 and 3. Titanium implants modified by laser with and without hydroxyapatite exhibit increased early osseointegration. © 2013 by Quintessence Publishing Co Inc.
id UNSP_e60a8401deaac1f5a7d3c8f99628279b
oai_identifier_str oai:repositorio.unesp.br:11449/220241
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coatingThe purpose of this study was nondecalcified histologic analysis of titanium implants modified by laser with and without hydroxyapatite. Implants with three modified surfaces were inserted into rabbit tibias: group 1, machined surface; group 2, irradiated (laser); and group 3, irradiated and hydroxyapatite coated (biomimetic method). The mean surface roughness (Ra) scores of groups 2 and 3 were higher than that of group 1. Boneimplant contact measurements at 30 and 60 days for groups 2 and 3 were higher than for group 1. Bone area at 30 and 60 days for group 2 was higher than for groups 1 and 3. Titanium implants modified by laser with and without hydroxyapatite exhibit increased early osseointegration. © 2013 by Quintessence Publishing Co Inc.Federal University of Mato Grosso do Sul, Campo Grande, Mato GrossoUniversity of Chieti-Pescara, ChietiUNESP, Campus de Araraquara, Sao PauloCentro Universitário de Araraquara - Uniara, Sao PauloUNESP, Campus de Araraquara, Sao PauloFederal University of Mato Grosso do SulUniversity of Chieti-PescaraUniversidade Estadual Paulista (UNESP)Centro Universitário de Araraquara - UniaraSisti, Karin E.Piattelli, AdrianoGuastaldi, Antonio C. [UNESP]Queiroz, Thallita P.De Rossi, Rafael2022-04-28T19:00:26Z2022-04-28T19:00:26Z2013-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article689-696http://dx.doi.org/10.11607/prd.1151International Journal of Periodontics and Restorative Dentistry, v. 33, n. 5, p. 689-696, 2013.1945-33880198-7569http://hdl.handle.net/11449/22024110.11607/prd.11512-s2.0-84908118191Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Journal of Periodontics and Restorative Dentistryinfo:eu-repo/semantics/openAccess2022-04-28T19:00:27Zoai:repositorio.unesp.br:11449/220241Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T18:05:13.988385Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating
title Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating
spellingShingle Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating
Sisti, Karin E.
title_short Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating
title_full Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating
title_fullStr Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating
title_full_unstemmed Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating
title_sort Nondecalcified histologic study of bone response to titanium implants topographically modified by laser with and without hydroxyapatite coating
author Sisti, Karin E.
author_facet Sisti, Karin E.
Piattelli, Adriano
Guastaldi, Antonio C. [UNESP]
Queiroz, Thallita P.
De Rossi, Rafael
author_role author
author2 Piattelli, Adriano
Guastaldi, Antonio C. [UNESP]
Queiroz, Thallita P.
De Rossi, Rafael
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Federal University of Mato Grosso do Sul
University of Chieti-Pescara
Universidade Estadual Paulista (UNESP)
Centro Universitário de Araraquara - Uniara
dc.contributor.author.fl_str_mv Sisti, Karin E.
Piattelli, Adriano
Guastaldi, Antonio C. [UNESP]
Queiroz, Thallita P.
De Rossi, Rafael
description The purpose of this study was nondecalcified histologic analysis of titanium implants modified by laser with and without hydroxyapatite. Implants with three modified surfaces were inserted into rabbit tibias: group 1, machined surface; group 2, irradiated (laser); and group 3, irradiated and hydroxyapatite coated (biomimetic method). The mean surface roughness (Ra) scores of groups 2 and 3 were higher than that of group 1. Boneimplant contact measurements at 30 and 60 days for groups 2 and 3 were higher than for group 1. Bone area at 30 and 60 days for group 2 was higher than for groups 1 and 3. Titanium implants modified by laser with and without hydroxyapatite exhibit increased early osseointegration. © 2013 by Quintessence Publishing Co Inc.
publishDate 2013
dc.date.none.fl_str_mv 2013-01-01
2022-04-28T19:00:26Z
2022-04-28T19:00:26Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.11607/prd.1151
International Journal of Periodontics and Restorative Dentistry, v. 33, n. 5, p. 689-696, 2013.
1945-3388
0198-7569
http://hdl.handle.net/11449/220241
10.11607/prd.1151
2-s2.0-84908118191
url http://dx.doi.org/10.11607/prd.1151
http://hdl.handle.net/11449/220241
identifier_str_mv International Journal of Periodontics and Restorative Dentistry, v. 33, n. 5, p. 689-696, 2013.
1945-3388
0198-7569
10.11607/prd.1151
2-s2.0-84908118191
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv International Journal of Periodontics and Restorative Dentistry
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 689-696
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128227300868096