Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images

Detalhes bibliográficos
Autor(a) principal: Mauad, Leticia Queiroz
Data de Publicação: 2021
Outros Autores: Teixeira Doriguetto, Paulo Victor, Almeida, Daniela de, Castilho Fardim, Karolina Aparecida [UNESP], Machado, Alessiana Helena, Devito, Karina Lopes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1259/dmfr.20200134
http://hdl.handle.net/11449/210062
Resumo: Objectives: To evaluate, in an in vitro study, the quantity of artefacts generated by two different restorative materials, and to determine the diagnostic accuracy of cone beam CT (CBCT) scans and periapical radiographs in identifying gaps in prosthetic crowns. Methods: A total of 30 teeth restored with metal-ceramic (n = 15) and all-ceramic (n = 15) crowns, properly adapted and with 0.30- and 0.50 mm gaps, underwent CBCT exams (with voxel sizes of 0.25 and 0.30 mm) and periapical radiographs. The artefacts generated by two different crowns were quantified and compared by the Mann-Whitney test. In addition, five examiners evaluated the presence or absence of gaps in periapical radiographs and CBCT images. The accuracy of tests was determined by the area under the receiver operatring characteristic curve and these values were compared by using the Kruskal-Wallis test. Results: There was no significant difference in artefact values between the different restorative materials and the different resolutions of CBCT images. Regarding the accuracy of the tests evaluated, periapical radiography and CBCT with voxel size 0.25 mm showed the best performance for smaller gaps (0.30 mm). For larger gaps (0.50 mm), all exams tested showed the same performance. Conclusions: Periapical radiography was still the most cost-beneficial method for the diagnosis of maladaptation in dental restorations. CBCT exams did not improve accuracy in detecting gaps in prosthetic crowns.
id UNSP_e6d463f9e1de8e9fac82d95982fffdd2
oai_identifier_str oai:repositorio.unesp.br:11449/210062
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT imagescone beam computed tomographyartefactsceramicsmetal ceramic alloysdental marginal adaptationObjectives: To evaluate, in an in vitro study, the quantity of artefacts generated by two different restorative materials, and to determine the diagnostic accuracy of cone beam CT (CBCT) scans and periapical radiographs in identifying gaps in prosthetic crowns. Methods: A total of 30 teeth restored with metal-ceramic (n = 15) and all-ceramic (n = 15) crowns, properly adapted and with 0.30- and 0.50 mm gaps, underwent CBCT exams (with voxel sizes of 0.25 and 0.30 mm) and periapical radiographs. The artefacts generated by two different crowns were quantified and compared by the Mann-Whitney test. In addition, five examiners evaluated the presence or absence of gaps in periapical radiographs and CBCT images. The accuracy of tests was determined by the area under the receiver operatring characteristic curve and these values were compared by using the Kruskal-Wallis test. Results: There was no significant difference in artefact values between the different restorative materials and the different resolutions of CBCT images. Regarding the accuracy of the tests evaluated, periapical radiography and CBCT with voxel size 0.25 mm showed the best performance for smaller gaps (0.30 mm). For larger gaps (0.50 mm), all exams tested showed the same performance. Conclusions: Periapical radiography was still the most cost-beneficial method for the diagnosis of maladaptation in dental restorations. CBCT exams did not improve accuracy in detecting gaps in prosthetic crowns.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Univ Fed Juiz de Fora, Sch Dent, Grad Program Dent, Juiz De Fora, MG, BrazilSao Paulo State Univ, Sch Dent, Inst Sci & Technol, Dept Oral Diag & Surg, Sao Jose Dos Campos, SP, BrazilUniv Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Piracicaba, SP, BrazilUniv Fed Juiz de Fora, Sch Dent, Dept Dent Clin, Juiz De Fora, MG, BrazilSao Paulo State Univ, Sch Dent, Inst Sci & Technol, Dept Oral Diag & Surg, Sao Jose Dos Campos, SP, BrazilCAPES: 001British Inst RadiologyUniv Fed Juiz de ForaUniversidade Estadual Paulista (Unesp)Universidade Estadual de Campinas (UNICAMP)Mauad, Leticia QueirozTeixeira Doriguetto, Paulo VictorAlmeida, Daniela deCastilho Fardim, Karolina Aparecida [UNESP]Machado, Alessiana HelenaDevito, Karina Lopes2021-06-25T12:38:29Z2021-06-25T12:38:29Z2021-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article7http://dx.doi.org/10.1259/dmfr.20200134Dentomaxillofacial Radiology. London: British Inst Radiology, v. 50, n. 3, 7 p., 2021.0250-832Xhttp://hdl.handle.net/11449/21006210.1259/dmfr.20200134WOS:000621319000001Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengDentomaxillofacial Radiologyinfo:eu-repo/semantics/openAccess2021-10-23T20:11:09Zoai:repositorio.unesp.br:11449/210062Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:39:37.878377Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images
title Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images
spellingShingle Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images
Mauad, Leticia Queiroz
cone beam computed tomography
artefacts
ceramics
metal ceramic alloys
dental marginal adaptation
title_short Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images
title_full Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images
title_fullStr Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images
title_full_unstemmed Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images
title_sort Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images
author Mauad, Leticia Queiroz
author_facet Mauad, Leticia Queiroz
Teixeira Doriguetto, Paulo Victor
Almeida, Daniela de
Castilho Fardim, Karolina Aparecida [UNESP]
Machado, Alessiana Helena
Devito, Karina Lopes
author_role author
author2 Teixeira Doriguetto, Paulo Victor
Almeida, Daniela de
Castilho Fardim, Karolina Aparecida [UNESP]
Machado, Alessiana Helena
Devito, Karina Lopes
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Univ Fed Juiz de Fora
Universidade Estadual Paulista (Unesp)
Universidade Estadual de Campinas (UNICAMP)
dc.contributor.author.fl_str_mv Mauad, Leticia Queiroz
Teixeira Doriguetto, Paulo Victor
Almeida, Daniela de
Castilho Fardim, Karolina Aparecida [UNESP]
Machado, Alessiana Helena
Devito, Karina Lopes
dc.subject.por.fl_str_mv cone beam computed tomography
artefacts
ceramics
metal ceramic alloys
dental marginal adaptation
topic cone beam computed tomography
artefacts
ceramics
metal ceramic alloys
dental marginal adaptation
description Objectives: To evaluate, in an in vitro study, the quantity of artefacts generated by two different restorative materials, and to determine the diagnostic accuracy of cone beam CT (CBCT) scans and periapical radiographs in identifying gaps in prosthetic crowns. Methods: A total of 30 teeth restored with metal-ceramic (n = 15) and all-ceramic (n = 15) crowns, properly adapted and with 0.30- and 0.50 mm gaps, underwent CBCT exams (with voxel sizes of 0.25 and 0.30 mm) and periapical radiographs. The artefacts generated by two different crowns were quantified and compared by the Mann-Whitney test. In addition, five examiners evaluated the presence or absence of gaps in periapical radiographs and CBCT images. The accuracy of tests was determined by the area under the receiver operatring characteristic curve and these values were compared by using the Kruskal-Wallis test. Results: There was no significant difference in artefact values between the different restorative materials and the different resolutions of CBCT images. Regarding the accuracy of the tests evaluated, periapical radiography and CBCT with voxel size 0.25 mm showed the best performance for smaller gaps (0.30 mm). For larger gaps (0.50 mm), all exams tested showed the same performance. Conclusions: Periapical radiography was still the most cost-beneficial method for the diagnosis of maladaptation in dental restorations. CBCT exams did not improve accuracy in detecting gaps in prosthetic crowns.
publishDate 2021
dc.date.none.fl_str_mv 2021-06-25T12:38:29Z
2021-06-25T12:38:29Z
2021-01-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1259/dmfr.20200134
Dentomaxillofacial Radiology. London: British Inst Radiology, v. 50, n. 3, 7 p., 2021.
0250-832X
http://hdl.handle.net/11449/210062
10.1259/dmfr.20200134
WOS:000621319000001
url http://dx.doi.org/10.1259/dmfr.20200134
http://hdl.handle.net/11449/210062
identifier_str_mv Dentomaxillofacial Radiology. London: British Inst Radiology, v. 50, n. 3, 7 p., 2021.
0250-832X
10.1259/dmfr.20200134
WOS:000621319000001
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Dentomaxillofacial Radiology
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 7
dc.publisher.none.fl_str_mv British Inst Radiology
publisher.none.fl_str_mv British Inst Radiology
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129102271479808