Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins

Detalhes bibliográficos
Autor(a) principal: Seo, Rosangela Seiko
Data de Publicação: 2007
Outros Autores: Vergani, Carlos Eduardo [UNESP], Giampaolo, Eunice Teresinha [UNESP], Pavarina, Ana Claudia [UNESP], Machado, Ana Lucia [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/S1678-77572007000600010
http://hdl.handle.net/11449/69957
Resumo: This study evaluated the effect of water-bath and microwave post-polymerization treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard C-UGH) and one heat-polymerized acrylic resin (Lucitone 550-L), processed using two polymerization cycles (short cycle - 90 minutes at 73°C and 100°C for 30 minutes; and long cycle - 9 hours at 71°C). For each material, thirty specimens (64 x 10 x 3.3 mm) were made and divided into 3 groups (n=10). Specimens were tested after: processing (control group); water-bath at 55°C for 10 minutes (reline materials) or 60 minutes (L); and microwave irradiation. Flexural strength tests were performed at a crosshead speed of 5 mm/min using a three-point bending device with a span of 50 mm. The flexural strengths values were calculated in MPa. One fragment of each specimen was submitted to Vickers hardness test. Data were analyzed by 2-way ANOVA followed by Tukey's HSD test (α=0.05). L microwaved specimens (short cycle) exhibited significantly higher flexural strength means than its respective control group (p<0.05). Water-bath promoted a significant increase (p<0.05) in flexural strength of K and L (long cycle). The hardness of the tested materials was not influenced by the post-polymerization treatments. Post-polymerization treatments could be used to improve the flexural strength of some materials tested.
id UNSP_e7c4bc614c47d8d89ea794a2edbdf651
oai_identifier_str oai:repositorio.unesp.br:11449/69957
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resinsAcrylic resinsDenture linersHardnessMicrowavesThis study evaluated the effect of water-bath and microwave post-polymerization treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard C-UGH) and one heat-polymerized acrylic resin (Lucitone 550-L), processed using two polymerization cycles (short cycle - 90 minutes at 73°C and 100°C for 30 minutes; and long cycle - 9 hours at 71°C). For each material, thirty specimens (64 x 10 x 3.3 mm) were made and divided into 3 groups (n=10). Specimens were tested after: processing (control group); water-bath at 55°C for 10 minutes (reline materials) or 60 minutes (L); and microwave irradiation. Flexural strength tests were performed at a crosshead speed of 5 mm/min using a three-point bending device with a span of 50 mm. The flexural strengths values were calculated in MPa. One fragment of each specimen was submitted to Vickers hardness test. Data were analyzed by 2-way ANOVA followed by Tukey's HSD test (α=0.05). L microwaved specimens (short cycle) exhibited significantly higher flexural strength means than its respective control group (p<0.05). Water-bath promoted a significant increase (p<0.05) in flexural strength of K and L (long cycle). The hardness of the tested materials was not influenced by the post-polymerization treatments. Post-polymerization treatments could be used to improve the flexural strength of some materials tested.Dental School University of Várzea Grande, Várzea Grande, MTDepartment of Dental Materials and Prosthodontics Dental School of Araraquara São Paulo State University, Araraquara, SPDepartment of Dental Materials and Prosthodontics São Paulo State University UNESP, Araraquara, SPFaculdade de Odontologia de Araraquara UNESP, Rua Humaitá no 1680, 14801-903 - Araraquara, SPDepartment of Dental Materials and Prosthodontics Dental School of Araraquara São Paulo State University, Araraquara, SPDepartment of Dental Materials and Prosthodontics São Paulo State University UNESP, Araraquara, SPFaculdade de Odontologia de Araraquara UNESP, Rua Humaitá no 1680, 14801-903 - Araraquara, SPUniversity of Várzea GrandeUniversidade Estadual Paulista (Unesp)Seo, Rosangela SeikoVergani, Carlos Eduardo [UNESP]Giampaolo, Eunice Teresinha [UNESP]Pavarina, Ana Claudia [UNESP]Machado, Ana Lucia [UNESP]2014-05-27T11:22:37Z2014-05-27T11:22:37Z2007-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article506-511application/pdfhttp://dx.doi.org/10.1590/S1678-77572007000600010Journal of Applied Oral Science, v. 15, n. 6, p. 506-511, 2007.1678-77571678-7765http://hdl.handle.net/11449/6995710.1590/S1678-77572007000600010S1678-77572007000600010WOS:0002567951000092-s2.0-380491366172-s2.0-38049136617.pdf30031305224278205737127334248549886767053910540380002487818425870000-0002-7375-4714Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Applied Oral Science1.7090,645info:eu-repo/semantics/openAccess2024-09-27T14:57:07Zoai:repositorio.unesp.br:11449/69957Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T14:57:07Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins
title Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins
spellingShingle Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins
Seo, Rosangela Seiko
Acrylic resins
Denture liners
Hardness
Microwaves
title_short Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins
title_full Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins
title_fullStr Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins
title_full_unstemmed Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins
title_sort Effect of a post-polymerization treatments on the flexural strength and vickers hardness of reline and acrylic denture base resins
author Seo, Rosangela Seiko
author_facet Seo, Rosangela Seiko
Vergani, Carlos Eduardo [UNESP]
Giampaolo, Eunice Teresinha [UNESP]
Pavarina, Ana Claudia [UNESP]
Machado, Ana Lucia [UNESP]
author_role author
author2 Vergani, Carlos Eduardo [UNESP]
Giampaolo, Eunice Teresinha [UNESP]
Pavarina, Ana Claudia [UNESP]
Machado, Ana Lucia [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv University of Várzea Grande
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Seo, Rosangela Seiko
Vergani, Carlos Eduardo [UNESP]
Giampaolo, Eunice Teresinha [UNESP]
Pavarina, Ana Claudia [UNESP]
Machado, Ana Lucia [UNESP]
dc.subject.por.fl_str_mv Acrylic resins
Denture liners
Hardness
Microwaves
topic Acrylic resins
Denture liners
Hardness
Microwaves
description This study evaluated the effect of water-bath and microwave post-polymerization treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard C-UGH) and one heat-polymerized acrylic resin (Lucitone 550-L), processed using two polymerization cycles (short cycle - 90 minutes at 73°C and 100°C for 30 minutes; and long cycle - 9 hours at 71°C). For each material, thirty specimens (64 x 10 x 3.3 mm) were made and divided into 3 groups (n=10). Specimens were tested after: processing (control group); water-bath at 55°C for 10 minutes (reline materials) or 60 minutes (L); and microwave irradiation. Flexural strength tests were performed at a crosshead speed of 5 mm/min using a three-point bending device with a span of 50 mm. The flexural strengths values were calculated in MPa. One fragment of each specimen was submitted to Vickers hardness test. Data were analyzed by 2-way ANOVA followed by Tukey's HSD test (α=0.05). L microwaved specimens (short cycle) exhibited significantly higher flexural strength means than its respective control group (p<0.05). Water-bath promoted a significant increase (p<0.05) in flexural strength of K and L (long cycle). The hardness of the tested materials was not influenced by the post-polymerization treatments. Post-polymerization treatments could be used to improve the flexural strength of some materials tested.
publishDate 2007
dc.date.none.fl_str_mv 2007-11-01
2014-05-27T11:22:37Z
2014-05-27T11:22:37Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1678-77572007000600010
Journal of Applied Oral Science, v. 15, n. 6, p. 506-511, 2007.
1678-7757
1678-7765
http://hdl.handle.net/11449/69957
10.1590/S1678-77572007000600010
S1678-77572007000600010
WOS:000256795100009
2-s2.0-38049136617
2-s2.0-38049136617.pdf
3003130522427820
5737127334248549
8867670539105403
8000248781842587
0000-0002-7375-4714
url http://dx.doi.org/10.1590/S1678-77572007000600010
http://hdl.handle.net/11449/69957
identifier_str_mv Journal of Applied Oral Science, v. 15, n. 6, p. 506-511, 2007.
1678-7757
1678-7765
10.1590/S1678-77572007000600010
S1678-77572007000600010
WOS:000256795100009
2-s2.0-38049136617
2-s2.0-38049136617.pdf
3003130522427820
5737127334248549
8867670539105403
8000248781842587
0000-0002-7375-4714
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Applied Oral Science
1.709
0,645
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 506-511
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546460292055040