Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
DOI: | 10.17344/acsi.2020.6177 |
Texto Completo: | http://dx.doi.org/10.17344/acsi.2020.6177 http://hdl.handle.net/11449/207308 |
Resumo: | Insulin is an important anabolic hormone that regulates the metabolism of carbohydrates, lipids and proteins. In this study, a reverse-phase liquid chromatography (RP-LC) method was successfully validated and tested for the encapsulation efficiency assay of insulin and in vitro release studies. HPLC analyses were carried out using a RP C18- Luna® Phenomenex (4.6 × 250 mm, 5 μm particle size) column maintained at room temperature, using a mobile phase constituted by a mixture of acetonitrile and 0.1% TFA aqueous solution (60:40, v/v), in an isocratic mode with a flow rate of 1.0 mL/ min, with ultraviolet detection at 214 nm and 20 μL of injection volume. Method validation was performed according recognized guidelines for system suitability, specificity, linearity, precision, accuracy, LOD, LOQ and robustness. The method was shown to be linear in the range of 0.5–100 µg/mL (r2 = 0.9993) selective, precise, robust, accurate with LOD and LOQ values were 0.097 µg/mL and 0.294 µg/mL, respectively. The developed method proved to be adequate to analyze the encapsulation efficiency and the profile of insulin release from liposomes. |
id |
UNSP_e88b62ab5ad4a540c69c1892d773d7fd |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/207308 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLCEncapsulation EfficiencyIn Vitro ReleaseInsulinLiposomeLiquid ChromatographyValidation MethodInsulin is an important anabolic hormone that regulates the metabolism of carbohydrates, lipids and proteins. In this study, a reverse-phase liquid chromatography (RP-LC) method was successfully validated and tested for the encapsulation efficiency assay of insulin and in vitro release studies. HPLC analyses were carried out using a RP C18- Luna® Phenomenex (4.6 × 250 mm, 5 μm particle size) column maintained at room temperature, using a mobile phase constituted by a mixture of acetonitrile and 0.1% TFA aqueous solution (60:40, v/v), in an isocratic mode with a flow rate of 1.0 mL/ min, with ultraviolet detection at 214 nm and 20 μL of injection volume. Method validation was performed according recognized guidelines for system suitability, specificity, linearity, precision, accuracy, LOD, LOQ and robustness. The method was shown to be linear in the range of 0.5–100 µg/mL (r2 = 0.9993) selective, precise, robust, accurate with LOD and LOQ values were 0.097 µg/mL and 0.294 µg/mL, respectively. The developed method proved to be adequate to analyze the encapsulation efficiency and the profile of insulin release from liposomes.São Paulo State University (UNESP) School of Pharmaceutical Sciences Department of Drugs and Medicines, Rodovia Araraquara-Jaú, km1Federal University of Ceará School of Pharmacy Dentistry and Nursing Department of PharmacySão Paulo State University (UNESP) School of Pharmaceutical Sciences Department of Drugs and Medicines, Rodovia Araraquara-Jaú, km1Universidade Estadual Paulista (Unesp)Dentistry and Nursingde Souza Von Zuben, Eliete [UNESP]Eloy, Josimar OliveiraSousa Araujo, Victor Hugo [UNESP]Daflon Gremião, Maria Palmira [UNESP]Chorilli, Marlus [UNESP]2021-06-25T10:52:59Z2021-06-25T10:52:59Z2020-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1273-1280http://dx.doi.org/10.17344/acsi.2020.6177Acta Chimica Slovenica, v. 67, n. 4, p. 1273-1280, 2020.1580-31551318-0207http://hdl.handle.net/11449/20730810.17344/acsi.2020.61772-s2.0-85101022606Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengActa Chimica Slovenicainfo:eu-repo/semantics/openAccess2024-06-24T13:46:33Zoai:repositorio.unesp.br:11449/207308Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T23:39:25.371754Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC |
title |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC |
spellingShingle |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC de Souza Von Zuben, Eliete [UNESP] Encapsulation Efficiency In Vitro Release Insulin Liposome Liquid Chromatography Validation Method de Souza Von Zuben, Eliete [UNESP] Encapsulation Efficiency In Vitro Release Insulin Liposome Liquid Chromatography Validation Method |
title_short |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC |
title_full |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC |
title_fullStr |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC |
title_full_unstemmed |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC |
title_sort |
Rapid and sensitive analytical method for the determination of insulin in liposomes by reversed-phase HPLC |
author |
de Souza Von Zuben, Eliete [UNESP] |
author_facet |
de Souza Von Zuben, Eliete [UNESP] de Souza Von Zuben, Eliete [UNESP] Eloy, Josimar Oliveira Sousa Araujo, Victor Hugo [UNESP] Daflon Gremião, Maria Palmira [UNESP] Chorilli, Marlus [UNESP] Eloy, Josimar Oliveira Sousa Araujo, Victor Hugo [UNESP] Daflon Gremião, Maria Palmira [UNESP] Chorilli, Marlus [UNESP] |
author_role |
author |
author2 |
Eloy, Josimar Oliveira Sousa Araujo, Victor Hugo [UNESP] Daflon Gremião, Maria Palmira [UNESP] Chorilli, Marlus [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Dentistry and Nursing |
dc.contributor.author.fl_str_mv |
de Souza Von Zuben, Eliete [UNESP] Eloy, Josimar Oliveira Sousa Araujo, Victor Hugo [UNESP] Daflon Gremião, Maria Palmira [UNESP] Chorilli, Marlus [UNESP] |
dc.subject.por.fl_str_mv |
Encapsulation Efficiency In Vitro Release Insulin Liposome Liquid Chromatography Validation Method |
topic |
Encapsulation Efficiency In Vitro Release Insulin Liposome Liquid Chromatography Validation Method |
description |
Insulin is an important anabolic hormone that regulates the metabolism of carbohydrates, lipids and proteins. In this study, a reverse-phase liquid chromatography (RP-LC) method was successfully validated and tested for the encapsulation efficiency assay of insulin and in vitro release studies. HPLC analyses were carried out using a RP C18- Luna® Phenomenex (4.6 × 250 mm, 5 μm particle size) column maintained at room temperature, using a mobile phase constituted by a mixture of acetonitrile and 0.1% TFA aqueous solution (60:40, v/v), in an isocratic mode with a flow rate of 1.0 mL/ min, with ultraviolet detection at 214 nm and 20 μL of injection volume. Method validation was performed according recognized guidelines for system suitability, specificity, linearity, precision, accuracy, LOD, LOQ and robustness. The method was shown to be linear in the range of 0.5–100 µg/mL (r2 = 0.9993) selective, precise, robust, accurate with LOD and LOQ values were 0.097 µg/mL and 0.294 µg/mL, respectively. The developed method proved to be adequate to analyze the encapsulation efficiency and the profile of insulin release from liposomes. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-01-01 2021-06-25T10:52:59Z 2021-06-25T10:52:59Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.17344/acsi.2020.6177 Acta Chimica Slovenica, v. 67, n. 4, p. 1273-1280, 2020. 1580-3155 1318-0207 http://hdl.handle.net/11449/207308 10.17344/acsi.2020.6177 2-s2.0-85101022606 |
url |
http://dx.doi.org/10.17344/acsi.2020.6177 http://hdl.handle.net/11449/207308 |
identifier_str_mv |
Acta Chimica Slovenica, v. 67, n. 4, p. 1273-1280, 2020. 1580-3155 1318-0207 10.17344/acsi.2020.6177 2-s2.0-85101022606 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Acta Chimica Slovenica |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1273-1280 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1822182241275478016 |
dc.identifier.doi.none.fl_str_mv |
10.17344/acsi.2020.6177 |