RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR

Detalhes bibliográficos
Autor(a) principal: Gazoli, Jonas Rafael
Data de Publicação: 2011
Outros Autores: Oliveira F, Milton Evangelista de, Espindola, Marcos Fernando, Siqueira, Thais Gama de, Villalva, Marcelo Gradella [UNESP], Ruppert, Ernesto, IEEE
Tipo de documento: Artigo de conferência
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/194818
Resumo: Voltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the inverter input current but this also affects the load with low-order harmonics and generate disturbances at the input voltage. This paper applies the P+RES controller to solve the challenge of regulating the output current by means of controlling the magnitude of the current space vector, keeping it constant thus rejecting harmonic disturbances that would otherwise propagate to the load. This work presents a discussion of the switching and control strategy.
id UNSP_ea6fa702a72228eb25a4e890da610bbe
oai_identifier_str oai:repositorio.unesp.br:11449/194818
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITORcurrent controlreduced dc link capacitorp plus resresonant controllerspace vectorvoltage source inverterVoltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the inverter input current but this also affects the load with low-order harmonics and generate disturbances at the input voltage. This paper applies the P+RES controller to solve the challenge of regulating the output current by means of controlling the magnitude of the current space vector, keeping it constant thus rejecting harmonic disturbances that would otherwise propagate to the load. This work presents a discussion of the switching and control strategy.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Univ Estadual Campinas UNICAMP, DSCE FEEC, Lab Eletron Potencia, Campinas, SP, BrazilUniv Estadual Paulista UNESP, GASI, Sorocaba, SP, BrazilUniv Fed Alfenas UNIFAL, Inst Ciencia & Tecnol, Pocos De Caldas, MG, BrazilUniv Estadual Paulista UNESP, GASI, Sorocaba, SP, BrazilFAPESP: 10/15848-7FAPESP: 08/07956-4FAPESP: 10/50101-0IeeeUniversidade Estadual de Campinas (UNICAMP)Universidade Estadual Paulista (Unesp)Univ Fed Alfenas UNIFALGazoli, Jonas RafaelOliveira F, Milton Evangelista deEspindola, Marcos FernandoSiqueira, Thais Gama deVillalva, Marcelo Gradella [UNESP]Ruppert, ErnestoIEEE2020-12-10T16:55:26Z2020-12-10T16:55:26Z2011-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject409-414Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 409-414, 2011.2175-8603http://hdl.handle.net/11449/194818WOS:000395311200065Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengXi Brazilian Power Electronics Conference (cobep 2011)info:eu-repo/semantics/openAccess2021-10-22T21:10:06Zoai:repositorio.unesp.br:11449/194818Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T14:33:45.958466Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
title RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
spellingShingle RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
Gazoli, Jonas Rafael
current control
reduced dc link capacitor
p plus res
resonant controller
space vector
voltage source inverter
title_short RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
title_full RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
title_fullStr RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
title_full_unstemmed RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
title_sort RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
author Gazoli, Jonas Rafael
author_facet Gazoli, Jonas Rafael
Oliveira F, Milton Evangelista de
Espindola, Marcos Fernando
Siqueira, Thais Gama de
Villalva, Marcelo Gradella [UNESP]
Ruppert, Ernesto
IEEE
author_role author
author2 Oliveira F, Milton Evangelista de
Espindola, Marcos Fernando
Siqueira, Thais Gama de
Villalva, Marcelo Gradella [UNESP]
Ruppert, Ernesto
IEEE
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual de Campinas (UNICAMP)
Universidade Estadual Paulista (Unesp)
Univ Fed Alfenas UNIFAL
dc.contributor.author.fl_str_mv Gazoli, Jonas Rafael
Oliveira F, Milton Evangelista de
Espindola, Marcos Fernando
Siqueira, Thais Gama de
Villalva, Marcelo Gradella [UNESP]
Ruppert, Ernesto
IEEE
dc.subject.por.fl_str_mv current control
reduced dc link capacitor
p plus res
resonant controller
space vector
voltage source inverter
topic current control
reduced dc link capacitor
p plus res
resonant controller
space vector
voltage source inverter
description Voltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the inverter input current but this also affects the load with low-order harmonics and generate disturbances at the input voltage. This paper applies the P+RES controller to solve the challenge of regulating the output current by means of controlling the magnitude of the current space vector, keeping it constant thus rejecting harmonic disturbances that would otherwise propagate to the load. This work presents a discussion of the switching and control strategy.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
2020-12-10T16:55:26Z
2020-12-10T16:55:26Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 409-414, 2011.
2175-8603
http://hdl.handle.net/11449/194818
WOS:000395311200065
identifier_str_mv Xi Brazilian Power Electronics Conference (cobep 2011). New York: Ieee, p. 409-414, 2011.
2175-8603
WOS:000395311200065
url http://hdl.handle.net/11449/194818
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Xi Brazilian Power Electronics Conference (cobep 2011)
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 409-414
dc.publisher.none.fl_str_mv Ieee
publisher.none.fl_str_mv Ieee
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128378502381568