Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study

Detalhes bibliográficos
Autor(a) principal: Mariños Rosado, Diego Jhovanny [UNESP]
Data de Publicação: 2019
Outros Autores: Rojas Chavez, Samir B. [UNESP], Carvalho, Joao A. de [UNESP], Chucuya Huallpachoque, Roberto C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.enconman.2018.12.111
http://hdl.handle.net/11449/184378
Resumo: The present investigation is developed in the refrigeration industry, whose activity is the production and commercialization of the ice used mainly in the fishing industry. The development consists in evaluating and comparing the steam compression refrigeration system with intercooler and the steam compression refrigeration system with compressor scale system. These evaluations are intended to determine the COP in both systems through an energetic and exergetic analysis, as well as to reduce the freezing time of the ice without affecting its quality. Finally, a thermoeconomic evaluation of these systems will be carried out to allow the company to analyze the convenience in study, by reducing their production costs using their productive processes efficiently, providing quality products, and being competitive in the market. It is evident that when carrying out the evaluation of the refrigeration system with compressor scale system, it will be possible to increase the exergetic efficiency, reduce the irreversibilities and the destroyed exergy; Above all, the COP will be increased by 8.28%, which allows a reduction in ice freezing time by 22.25% or 3 h and 39 min. In addition to obtaining savings in electricity consumption equivalent to $8563.00 dollars in the next 12 months.
id UNSP_eadc54fde331faab7dfcbea9977a2754
oai_identifier_str oai:repositorio.unesp.br:11449/184378
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case studyCoefficient of performanceCompressor scale systemIntercoolerRefrigeration industrySteam compressionThe present investigation is developed in the refrigeration industry, whose activity is the production and commercialization of the ice used mainly in the fishing industry. The development consists in evaluating and comparing the steam compression refrigeration system with intercooler and the steam compression refrigeration system with compressor scale system. These evaluations are intended to determine the COP in both systems through an energetic and exergetic analysis, as well as to reduce the freezing time of the ice without affecting its quality. Finally, a thermoeconomic evaluation of these systems will be carried out to allow the company to analyze the convenience in study, by reducing their production costs using their productive processes efficiently, providing quality products, and being competitive in the market. It is evident that when carrying out the evaluation of the refrigeration system with compressor scale system, it will be possible to increase the exergetic efficiency, reduce the irreversibilities and the destroyed exergy; Above all, the COP will be increased by 8.28%, which allows a reduction in ice freezing time by 22.25% or 3 h and 39 min. In addition to obtaining savings in electricity consumption equivalent to $8563.00 dollars in the next 12 months.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Sao Paulo State Univ, Campus Guaratingueta,Ave Ariberto P Cunha,333, Guaratingueta, SP, BrazilNatl Univ Santa, Dept Energy & Phys, Ave Pacifico 508, Chimbote, Ancash, PeruSao Paulo State Univ, Campus Guaratingueta,Ave Ariberto P Cunha,333, Guaratingueta, SP, BrazilFAPESP: 2017/08975-1Elsevier B.V.Universidade Estadual Paulista (Unesp)Natl Univ SantaMariños Rosado, Diego Jhovanny [UNESP]Rojas Chavez, Samir B. [UNESP]Carvalho, Joao A. de [UNESP]Chucuya Huallpachoque, Roberto C.2019-10-04T11:57:22Z2019-10-04T11:57:22Z2019-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article406-417http://dx.doi.org/10.1016/j.enconman.2018.12.111Energy Conversion And Management. Oxford: Pergamon-elsevier Science Ltd, v. 183, p. 406-417, 2019.0196-8904http://hdl.handle.net/11449/18437810.1016/j.enconman.2018.12.111WOS:000459837600033Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengEnergy Conversion And Managementinfo:eu-repo/semantics/openAccess2023-04-11T14:47:39Zoai:repositorio.unesp.br:11449/184378Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-04-11T14:47:39Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study
title Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study
spellingShingle Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study
Mariños Rosado, Diego Jhovanny [UNESP]
Coefficient of performance
Compressor scale system
Intercooler
Refrigeration industry
Steam compression
title_short Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study
title_full Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study
title_fullStr Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study
title_full_unstemmed Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study
title_sort Comparison between the steam compression refrigeration system with intercooler and with compressor scale system: A case study
author Mariños Rosado, Diego Jhovanny [UNESP]
author_facet Mariños Rosado, Diego Jhovanny [UNESP]
Rojas Chavez, Samir B. [UNESP]
Carvalho, Joao A. de [UNESP]
Chucuya Huallpachoque, Roberto C.
author_role author
author2 Rojas Chavez, Samir B. [UNESP]
Carvalho, Joao A. de [UNESP]
Chucuya Huallpachoque, Roberto C.
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Natl Univ Santa
dc.contributor.author.fl_str_mv Mariños Rosado, Diego Jhovanny [UNESP]
Rojas Chavez, Samir B. [UNESP]
Carvalho, Joao A. de [UNESP]
Chucuya Huallpachoque, Roberto C.
dc.subject.por.fl_str_mv Coefficient of performance
Compressor scale system
Intercooler
Refrigeration industry
Steam compression
topic Coefficient of performance
Compressor scale system
Intercooler
Refrigeration industry
Steam compression
description The present investigation is developed in the refrigeration industry, whose activity is the production and commercialization of the ice used mainly in the fishing industry. The development consists in evaluating and comparing the steam compression refrigeration system with intercooler and the steam compression refrigeration system with compressor scale system. These evaluations are intended to determine the COP in both systems through an energetic and exergetic analysis, as well as to reduce the freezing time of the ice without affecting its quality. Finally, a thermoeconomic evaluation of these systems will be carried out to allow the company to analyze the convenience in study, by reducing their production costs using their productive processes efficiently, providing quality products, and being competitive in the market. It is evident that when carrying out the evaluation of the refrigeration system with compressor scale system, it will be possible to increase the exergetic efficiency, reduce the irreversibilities and the destroyed exergy; Above all, the COP will be increased by 8.28%, which allows a reduction in ice freezing time by 22.25% or 3 h and 39 min. In addition to obtaining savings in electricity consumption equivalent to $8563.00 dollars in the next 12 months.
publishDate 2019
dc.date.none.fl_str_mv 2019-10-04T11:57:22Z
2019-10-04T11:57:22Z
2019-03-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.enconman.2018.12.111
Energy Conversion And Management. Oxford: Pergamon-elsevier Science Ltd, v. 183, p. 406-417, 2019.
0196-8904
http://hdl.handle.net/11449/184378
10.1016/j.enconman.2018.12.111
WOS:000459837600033
url http://dx.doi.org/10.1016/j.enconman.2018.12.111
http://hdl.handle.net/11449/184378
identifier_str_mv Energy Conversion And Management. Oxford: Pergamon-elsevier Science Ltd, v. 183, p. 406-417, 2019.
0196-8904
10.1016/j.enconman.2018.12.111
WOS:000459837600033
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Energy Conversion And Management
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 406-417
dc.publisher.none.fl_str_mv Elsevier B.V.
publisher.none.fl_str_mv Elsevier B.V.
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1803650383717859328