Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.3390/bios12060376 http://hdl.handle.net/11449/241670 |
Resumo: | Methylmercury (MeHg) is one of the most toxic organic mercury compounds found in the environment. The continuous exposure of human beings to this highly toxic compound may damage their nervous system. The present work reports the development and application of a novel electrochemical sensing technique for the quantification of MeHg using a modified carbon paste electrode with multi-walled carbon nanotubes (MWCNTs) combined with ion imprinted polymer, which is highly selective toward MeHg (CPE/MWCNTs/IIP-MeHg) detection. The ion imprinted polymer was synthesized using 2-mercaptobenzothiazole (MBT), acrylic acid (AA) and MeHg employed as ligand, functional monomer and template ion, respectively, and the synthesized material was characterized by Raman spectroscopy and SEM-EDX. Both the proposed and control sensors were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The electrochemical measurements were carried out using differential pulse stripping voltammetry (DPSV), and a well-defined anodic peak observed at about +0.138 V (vs. Ag/AgCl) was recorded for MeHg. The application of the CPE/MWCNTs/IIP-MeHg sensor (which increased the charge transfer on the electrode surface) under the DPSV-based electrochemical method (which enhanced the signal intensity) made the detection technique highly sensitive and selective for the quantification of methylmercury. Under optimum experimental conditions, the proposed sensor exhibited a linear response range of 560–610 µg L−1 and a detection limit of 0.538 µg L−1, with acceptable relative error values ≤1% when applied for the detection of MeHg in real water samples. |
id |
UNSP_ec67db38d2c8af1036f2df5760061ac9 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/241670 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Sampleselectrochemical sensorIIPsmethylmercury quantificationMethylmercury (MeHg) is one of the most toxic organic mercury compounds found in the environment. The continuous exposure of human beings to this highly toxic compound may damage their nervous system. The present work reports the development and application of a novel electrochemical sensing technique for the quantification of MeHg using a modified carbon paste electrode with multi-walled carbon nanotubes (MWCNTs) combined with ion imprinted polymer, which is highly selective toward MeHg (CPE/MWCNTs/IIP-MeHg) detection. The ion imprinted polymer was synthesized using 2-mercaptobenzothiazole (MBT), acrylic acid (AA) and MeHg employed as ligand, functional monomer and template ion, respectively, and the synthesized material was characterized by Raman spectroscopy and SEM-EDX. Both the proposed and control sensors were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The electrochemical measurements were carried out using differential pulse stripping voltammetry (DPSV), and a well-defined anodic peak observed at about +0.138 V (vs. Ag/AgCl) was recorded for MeHg. The application of the CPE/MWCNTs/IIP-MeHg sensor (which increased the charge transfer on the electrode surface) under the DPSV-based electrochemical method (which enhanced the signal intensity) made the detection technique highly sensitive and selective for the quantification of methylmercury. Under optimum experimental conditions, the proposed sensor exhibited a linear response range of 560–610 µg L−1 and a detection limit of 0.538 µg L−1, with acceptable relative error values ≤1% when applied for the detection of MeHg in real water samples.Fondo Nacional de Desarrollo Científico y TecnológicoLaboratory of Physical Chemistry Research Faculty of Sciences National University of Engineering, Av. Tupac Amaru 210Institute of Chemistry São Paulo State University (UNESP), P.O. Box 14801-970Institute of Chemistry São Paulo State University (UNESP), P.O. Box 14801-970National University of EngineeringUniversidade Estadual Paulista (UNESP)Mesa, RuddyKhan, Sabir [UNESP]Sotomayor, Maria D. P. T. [UNESP]Picasso, Gino2023-03-01T21:16:06Z2023-03-01T21:16:06Z2022-06-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.3390/bios12060376Biosensors, v. 12, n. 6, 2022.2079-6374http://hdl.handle.net/11449/24167010.3390/bios120603762-s2.0-85132272813Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBiosensorsinfo:eu-repo/semantics/openAccess2024-06-10T14:49:17Zoai:repositorio.unesp.br:11449/241670Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:56:45.776477Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples |
title |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples |
spellingShingle |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples Mesa, Ruddy electrochemical sensor IIPs methylmercury quantification |
title_short |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples |
title_full |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples |
title_fullStr |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples |
title_full_unstemmed |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples |
title_sort |
Using Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Samples |
author |
Mesa, Ruddy |
author_facet |
Mesa, Ruddy Khan, Sabir [UNESP] Sotomayor, Maria D. P. T. [UNESP] Picasso, Gino |
author_role |
author |
author2 |
Khan, Sabir [UNESP] Sotomayor, Maria D. P. T. [UNESP] Picasso, Gino |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
National University of Engineering Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Mesa, Ruddy Khan, Sabir [UNESP] Sotomayor, Maria D. P. T. [UNESP] Picasso, Gino |
dc.subject.por.fl_str_mv |
electrochemical sensor IIPs methylmercury quantification |
topic |
electrochemical sensor IIPs methylmercury quantification |
description |
Methylmercury (MeHg) is one of the most toxic organic mercury compounds found in the environment. The continuous exposure of human beings to this highly toxic compound may damage their nervous system. The present work reports the development and application of a novel electrochemical sensing technique for the quantification of MeHg using a modified carbon paste electrode with multi-walled carbon nanotubes (MWCNTs) combined with ion imprinted polymer, which is highly selective toward MeHg (CPE/MWCNTs/IIP-MeHg) detection. The ion imprinted polymer was synthesized using 2-mercaptobenzothiazole (MBT), acrylic acid (AA) and MeHg employed as ligand, functional monomer and template ion, respectively, and the synthesized material was characterized by Raman spectroscopy and SEM-EDX. Both the proposed and control sensors were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The electrochemical measurements were carried out using differential pulse stripping voltammetry (DPSV), and a well-defined anodic peak observed at about +0.138 V (vs. Ag/AgCl) was recorded for MeHg. The application of the CPE/MWCNTs/IIP-MeHg sensor (which increased the charge transfer on the electrode surface) under the DPSV-based electrochemical method (which enhanced the signal intensity) made the detection technique highly sensitive and selective for the quantification of methylmercury. Under optimum experimental conditions, the proposed sensor exhibited a linear response range of 560–610 µg L−1 and a detection limit of 0.538 µg L−1, with acceptable relative error values ≤1% when applied for the detection of MeHg in real water samples. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-06-01 2023-03-01T21:16:06Z 2023-03-01T21:16:06Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.3390/bios12060376 Biosensors, v. 12, n. 6, 2022. 2079-6374 http://hdl.handle.net/11449/241670 10.3390/bios12060376 2-s2.0-85132272813 |
url |
http://dx.doi.org/10.3390/bios12060376 http://hdl.handle.net/11449/241670 |
identifier_str_mv |
Biosensors, v. 12, n. 6, 2022. 2079-6374 10.3390/bios12060376 2-s2.0-85132272813 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Biosensors |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129141604614144 |