Stress distribution on short implants with different designs: a photoelastic analysis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1080/03091902.2016.1239276 http://hdl.handle.net/11449/173569 |
Resumo: | Short dental implants have been used as an attempt to avoid bone grafts surgery, however there are few literature reports that evaluate changes to their design. Therefore, the aim of this study was to assess the effect of different short implant design on stress distribution through photoelastic analysis. Six external hexagon (5 × 5 mm) short dental implants with different design were used. Each group was treated with a single crown and a three element fixed partial dental prosthesis, resulting in a total of 12 photoelastic models. The assembling photoelastic model-implant-prosthesis was set in a circular polariscope where loads of 100N were applied on the occlusal surface with a Universal Test Machine (UTM). The tension fringes were photographed and later assessed qualitatively by a graphic software (Adobe Photoshop). Less high-intensity fringes were observed on the short implants with triangular threads, short external hexagon and flat apical profile. In conclusion, the macrodesign influenced the amount of stress distributed to the bone when short dental implants are placed. |
id |
UNSP_f59f4ca7eb5b53cf64fe536c601ba031 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/173569 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Stress distribution on short implants with different designs: a photoelastic analysisbiomechanicsDental implantsfixed partial prosthesisShort dental implants have been used as an attempt to avoid bone grafts surgery, however there are few literature reports that evaluate changes to their design. Therefore, the aim of this study was to assess the effect of different short implant design on stress distribution through photoelastic analysis. Six external hexagon (5 × 5 mm) short dental implants with different design were used. Each group was treated with a single crown and a three element fixed partial dental prosthesis, resulting in a total of 12 photoelastic models. The assembling photoelastic model-implant-prosthesis was set in a circular polariscope where loads of 100N were applied on the occlusal surface with a Universal Test Machine (UTM). The tension fringes were photographed and later assessed qualitatively by a graphic software (Adobe Photoshop). Less high-intensity fringes were observed on the short implants with triangular threads, short external hexagon and flat apical profile. In conclusion, the macrodesign influenced the amount of stress distributed to the bone when short dental implants are placed.Department of Dental Materials and Prosthodontics Aracatuba Dental School São Paulo State University (UNESP)Department of Dental Materials and Prosthodontics Aracatuba Dental School São Paulo State University (UNESP)Universidade Estadual Paulista (Unesp)Goiato, Marcelo Coelho [UNESP]de Medeiros, Rodrigo Antonio [UNESP]Sônego, Mariana Vilela [UNESP]de Lima, Taynara Maria Toito [UNESP]Pesqueira, Aldiéris Alves [UNESP]dos Santos, Daniela Micheline [UNESP]2018-12-11T17:06:20Z2018-12-11T17:06:20Z2017-02-17info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article115-121http://dx.doi.org/10.1080/03091902.2016.1239276Journal of Medical Engineering and Technology, v. 41, n. 2, p. 115-121, 2017.1464-522X0309-1902http://hdl.handle.net/11449/17356910.1080/03091902.2016.12392762-s2.0-849902166499719883814872582Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Medical Engineering and Technology0,389info:eu-repo/semantics/openAccess2024-09-19T14:51:59Zoai:repositorio.unesp.br:11449/173569Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-19T14:51:59Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Stress distribution on short implants with different designs: a photoelastic analysis |
title |
Stress distribution on short implants with different designs: a photoelastic analysis |
spellingShingle |
Stress distribution on short implants with different designs: a photoelastic analysis Goiato, Marcelo Coelho [UNESP] biomechanics Dental implants fixed partial prosthesis |
title_short |
Stress distribution on short implants with different designs: a photoelastic analysis |
title_full |
Stress distribution on short implants with different designs: a photoelastic analysis |
title_fullStr |
Stress distribution on short implants with different designs: a photoelastic analysis |
title_full_unstemmed |
Stress distribution on short implants with different designs: a photoelastic analysis |
title_sort |
Stress distribution on short implants with different designs: a photoelastic analysis |
author |
Goiato, Marcelo Coelho [UNESP] |
author_facet |
Goiato, Marcelo Coelho [UNESP] de Medeiros, Rodrigo Antonio [UNESP] Sônego, Mariana Vilela [UNESP] de Lima, Taynara Maria Toito [UNESP] Pesqueira, Aldiéris Alves [UNESP] dos Santos, Daniela Micheline [UNESP] |
author_role |
author |
author2 |
de Medeiros, Rodrigo Antonio [UNESP] Sônego, Mariana Vilela [UNESP] de Lima, Taynara Maria Toito [UNESP] Pesqueira, Aldiéris Alves [UNESP] dos Santos, Daniela Micheline [UNESP] |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Goiato, Marcelo Coelho [UNESP] de Medeiros, Rodrigo Antonio [UNESP] Sônego, Mariana Vilela [UNESP] de Lima, Taynara Maria Toito [UNESP] Pesqueira, Aldiéris Alves [UNESP] dos Santos, Daniela Micheline [UNESP] |
dc.subject.por.fl_str_mv |
biomechanics Dental implants fixed partial prosthesis |
topic |
biomechanics Dental implants fixed partial prosthesis |
description |
Short dental implants have been used as an attempt to avoid bone grafts surgery, however there are few literature reports that evaluate changes to their design. Therefore, the aim of this study was to assess the effect of different short implant design on stress distribution through photoelastic analysis. Six external hexagon (5 × 5 mm) short dental implants with different design were used. Each group was treated with a single crown and a three element fixed partial dental prosthesis, resulting in a total of 12 photoelastic models. The assembling photoelastic model-implant-prosthesis was set in a circular polariscope where loads of 100N were applied on the occlusal surface with a Universal Test Machine (UTM). The tension fringes were photographed and later assessed qualitatively by a graphic software (Adobe Photoshop). Less high-intensity fringes were observed on the short implants with triangular threads, short external hexagon and flat apical profile. In conclusion, the macrodesign influenced the amount of stress distributed to the bone when short dental implants are placed. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-02-17 2018-12-11T17:06:20Z 2018-12-11T17:06:20Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1080/03091902.2016.1239276 Journal of Medical Engineering and Technology, v. 41, n. 2, p. 115-121, 2017. 1464-522X 0309-1902 http://hdl.handle.net/11449/173569 10.1080/03091902.2016.1239276 2-s2.0-84990216649 9719883814872582 |
url |
http://dx.doi.org/10.1080/03091902.2016.1239276 http://hdl.handle.net/11449/173569 |
identifier_str_mv |
Journal of Medical Engineering and Technology, v. 41, n. 2, p. 115-121, 2017. 1464-522X 0309-1902 10.1080/03091902.2016.1239276 2-s2.0-84990216649 9719883814872582 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of Medical Engineering and Technology 0,389 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
115-121 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546512430399488 |