Influence of the power level of an ultra-sonic system on dental cavity preparation

Detalhes bibliográficos
Autor(a) principal: Josgrilberg, Érika Botelho [UNESP]
Data de Publicação: 2007
Outros Autores: Guimarães, Murilo de Sousa [UNESP], Pansani, Cyneu Aguiar [UNESP], Cordeiro, Rita de Cássia Loiola [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/S1806-83242007000400014
http://hdl.handle.net/11449/70225
Resumo: The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.
id UNSP_f970b08f616e7338aeb603ad0e68abd6
oai_identifier_str oai:repositorio.unesp.br:11449/70225
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Influence of the power level of an ultra-sonic system on dental cavity preparationDental cavity preparationDiamondTechnology, dentalUltrasonographydiamondanimalcattleclinical trialcontrolled clinical trialcontrolled studydental surgeryechographyequipment designinstrumentationmethodologynonparametric testrandomized controlled trialsurface propertytooth pulpultrasound therapyAnimalsCattleDental Cavity PreparationDental Pulp CavityEquipment DesignStatistics, NonparametricSurface PropertiesUltrasonic TherapyThe aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.Department of Pediatrics School of Dentistry of Araraquara São Paulo State University, São PauloDepartamento de Clínica Infantil, R. Humaitá 1680, Araraquara, SP 14801-903Department of Pediatrics School of Dentistry of Araraquara São Paulo State University, São PauloUniversidade Estadual Paulista (Unesp)Josgrilberg, Érika Botelho [UNESP]Guimarães, Murilo de Sousa [UNESP]Pansani, Cyneu Aguiar [UNESP]Cordeiro, Rita de Cássia Loiola [UNESP]2014-05-27T11:22:45Z2014-05-27T11:22:45Z2007-12-31info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article362-367application/pdfhttp://dx.doi.org/10.1590/S1806-83242007000400014Brazilian Oral Research, v. 21, n. 4, p. 362-367, 2007.1806-83241807-3107http://hdl.handle.net/11449/7022510.1590/S1806-83242007000400014S1806-832420070004000142-s2.0-373490901112-s2.0-37349090111.pdf45474059116343158185082796673527Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Oral Research1.223info:eu-repo/semantics/openAccess2024-09-26T14:21:36Zoai:repositorio.unesp.br:11449/70225Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-26T14:21:36Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Influence of the power level of an ultra-sonic system on dental cavity preparation
title Influence of the power level of an ultra-sonic system on dental cavity preparation
spellingShingle Influence of the power level of an ultra-sonic system on dental cavity preparation
Josgrilberg, Érika Botelho [UNESP]
Dental cavity preparation
Diamond
Technology, dental
Ultrasonography
diamond
animal
cattle
clinical trial
controlled clinical trial
controlled study
dental surgery
echography
equipment design
instrumentation
methodology
nonparametric test
randomized controlled trial
surface property
tooth pulp
ultrasound therapy
Animals
Cattle
Dental Cavity Preparation
Dental Pulp Cavity
Equipment Design
Statistics, Nonparametric
Surface Properties
Ultrasonic Therapy
title_short Influence of the power level of an ultra-sonic system on dental cavity preparation
title_full Influence of the power level of an ultra-sonic system on dental cavity preparation
title_fullStr Influence of the power level of an ultra-sonic system on dental cavity preparation
title_full_unstemmed Influence of the power level of an ultra-sonic system on dental cavity preparation
title_sort Influence of the power level of an ultra-sonic system on dental cavity preparation
author Josgrilberg, Érika Botelho [UNESP]
author_facet Josgrilberg, Érika Botelho [UNESP]
Guimarães, Murilo de Sousa [UNESP]
Pansani, Cyneu Aguiar [UNESP]
Cordeiro, Rita de Cássia Loiola [UNESP]
author_role author
author2 Guimarães, Murilo de Sousa [UNESP]
Pansani, Cyneu Aguiar [UNESP]
Cordeiro, Rita de Cássia Loiola [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Josgrilberg, Érika Botelho [UNESP]
Guimarães, Murilo de Sousa [UNESP]
Pansani, Cyneu Aguiar [UNESP]
Cordeiro, Rita de Cássia Loiola [UNESP]
dc.subject.por.fl_str_mv Dental cavity preparation
Diamond
Technology, dental
Ultrasonography
diamond
animal
cattle
clinical trial
controlled clinical trial
controlled study
dental surgery
echography
equipment design
instrumentation
methodology
nonparametric test
randomized controlled trial
surface property
tooth pulp
ultrasound therapy
Animals
Cattle
Dental Cavity Preparation
Dental Pulp Cavity
Equipment Design
Statistics, Nonparametric
Surface Properties
Ultrasonic Therapy
topic Dental cavity preparation
Diamond
Technology, dental
Ultrasonography
diamond
animal
cattle
clinical trial
controlled clinical trial
controlled study
dental surgery
echography
equipment design
instrumentation
methodology
nonparametric test
randomized controlled trial
surface property
tooth pulp
ultrasound therapy
Animals
Cattle
Dental Cavity Preparation
Dental Pulp Cavity
Equipment Design
Statistics, Nonparametric
Surface Properties
Ultrasonic Therapy
description The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.
publishDate 2007
dc.date.none.fl_str_mv 2007-12-31
2014-05-27T11:22:45Z
2014-05-27T11:22:45Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S1806-83242007000400014
Brazilian Oral Research, v. 21, n. 4, p. 362-367, 2007.
1806-8324
1807-3107
http://hdl.handle.net/11449/70225
10.1590/S1806-83242007000400014
S1806-83242007000400014
2-s2.0-37349090111
2-s2.0-37349090111.pdf
4547405911634315
8185082796673527
url http://dx.doi.org/10.1590/S1806-83242007000400014
http://hdl.handle.net/11449/70225
identifier_str_mv Brazilian Oral Research, v. 21, n. 4, p. 362-367, 2007.
1806-8324
1807-3107
10.1590/S1806-83242007000400014
S1806-83242007000400014
2-s2.0-37349090111
2-s2.0-37349090111.pdf
4547405911634315
8185082796673527
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Oral Research
1.223
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 362-367
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546438956679168