Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone

Detalhes bibliográficos
Autor(a) principal: Neves, José Bernardes das
Data de Publicação: 2005
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da USC
Texto Completo: http://localhost:8080/tede/handle/tede/71
Resumo: The search for aesthetics in single implant restoration has increasingly prioritized the use of pure ceramics components in order to try and substitute the use of the metal-ceramic crowns. A number of techniques and materials have been developed with the purpose to overcome the difficulties in the attainment of prosthesis in pure ceramics or either, prostheses that present, beyond the aesthetic quality of conventional ceramics, resistance mechanics and adequate marginal adaptation. The success of the single prosthetic restoration, supported by osseointegrated implants and the health of the surrounding tissues, is closely related to the precision and the adaptation of the components and the stability of the interface / abutment / prostheses pillar. The Brãnemark system, in the 90 s presented, the CeraOne abutment as a solution for the single tooth losses that consist of modifications and adaptations of the screwed prosthesis for the cemented restoration. Ten gold cylinders (Group 1), ten coping of alumina oxide (Group 2) and ten of Procera scanned All Ceram (Group 3), adapted on a brass base of cylindrical form, measuring 4cm of length x 2,5cm of diameter, contend six faces numbered and uniforms, were used as test body. In the center, one perforation with 4mm of diameter x 10mm of depth was confectioned in which was fixed an implants of 10 x 3,75mm (Nobel Biocare). In the CeraOne a vertical and horizontal laser marks were drawn in each face of the hexagon as a reference. The fits had been evaluated before and after the face-hardenings with the elastomer, with and without vibration, constituting three groups of ten bodies of each test. A comparing microscope Mitutoyo (Japan) was used with increase of 150 times for the reading of the measures and with precision of 1µm. The results for the test of Fisher in level of 5% of probability demonstrate that the group most steady was of the gold cylinder, with coefficient of 29, 43% variation; the group most unstable was the group of Procera All Ceram scanned with coefficient of 106,50% variation. In accordance with the statistic analysis of the fit marginal of the aesthetic prostheses, it could be concluded that: a) the three studied conditions (gold cilinder, coping of alumina oxide premachined and coping of alumina scanned) have shown statistically similar results amongst them regarding the values of marginal fit; b) it did not have statistics significant difference in the reduction of the fit with the utilization of vibration, in the three studied experimental conditions.
id USC_3b3de3f647ece73b194c44ab31c8d66c
oai_identifier_str oai:localhost:tede/71
network_acronym_str USC
network_name_str Biblioteca Digital de Teses e Dissertações da USC
repository_id_str
spelling Francischone, Carlos EduardoCPF:55930034834http://lattes.cnpq.br/5622847033913614CPF:30056934653http://lattes.cnpq.br/5712704809420184Neves, José Bernardes das2015-09-14T10:14:10Z2008-10-142005-02-15NEVES, José Bernardes das. Evaluation of marginal adjustment of prosthetic components on aesthetic intermediary ceraone. 2005. 158 f. Dissertação (Mestrado em Biologia Oral - Implantologia) - IASCJ - Universidade Sagrado Coração, Bauru, 2005.http://localhost:8080/tede/handle/tede/71The search for aesthetics in single implant restoration has increasingly prioritized the use of pure ceramics components in order to try and substitute the use of the metal-ceramic crowns. A number of techniques and materials have been developed with the purpose to overcome the difficulties in the attainment of prosthesis in pure ceramics or either, prostheses that present, beyond the aesthetic quality of conventional ceramics, resistance mechanics and adequate marginal adaptation. The success of the single prosthetic restoration, supported by osseointegrated implants and the health of the surrounding tissues, is closely related to the precision and the adaptation of the components and the stability of the interface / abutment / prostheses pillar. The Brãnemark system, in the 90 s presented, the CeraOne abutment as a solution for the single tooth losses that consist of modifications and adaptations of the screwed prosthesis for the cemented restoration. Ten gold cylinders (Group 1), ten coping of alumina oxide (Group 2) and ten of Procera scanned All Ceram (Group 3), adapted on a brass base of cylindrical form, measuring 4cm of length x 2,5cm of diameter, contend six faces numbered and uniforms, were used as test body. In the center, one perforation with 4mm of diameter x 10mm of depth was confectioned in which was fixed an implants of 10 x 3,75mm (Nobel Biocare). In the CeraOne a vertical and horizontal laser marks were drawn in each face of the hexagon as a reference. The fits had been evaluated before and after the face-hardenings with the elastomer, with and without vibration, constituting three groups of ten bodies of each test. A comparing microscope Mitutoyo (Japan) was used with increase of 150 times for the reading of the measures and with precision of 1µm. The results for the test of Fisher in level of 5% of probability demonstrate that the group most steady was of the gold cylinder, with coefficient of 29, 43% variation; the group most unstable was the group of Procera All Ceram scanned with coefficient of 106,50% variation. In accordance with the statistic analysis of the fit marginal of the aesthetic prostheses, it could be concluded that: a) the three studied conditions (gold cilinder, coping of alumina oxide premachined and coping of alumina scanned) have shown statistically similar results amongst them regarding the values of marginal fit; b) it did not have statistics significant difference in the reduction of the fit with the utilization of vibration, in the three studied experimental conditions.A estética em implantes unitários tem priorizado a utilização cada vez maior de componentes de cerâmica pura na expectativa de substituições das metalocerâmicas. Muitas técnicas e materiais têm surgido com a finalidade de suprir as dificuldades na obtenção de próteses em cerâmica pura ou seja, próteses que apresentem, além da qualidade estética das cerâmicas convencionais, resistência mecânica e adaptação marginal adequada. O sucesso da restauração protética unitária, suportada por implantes osseointegrados e a saúde dos tecidos circundantes, está intimamente relacionado à precisão e à adaptação dos componentes na estabilidade da interface implante / intermediário / pilar protético. O sistema Bränemark apresentou, por volta de 1990, o intermediário CeraOne para resolução de perdas unitárias que consistem em modificações e adequações das próteses parafusadas para as cimentadas. Para a obtenção dos corpos de prova foram utilizados dez cilindros de ouro (Grupo 1), dez coifas de óxido de alumina (Grupo 2) e dez de Procera All Ceram escaneadas (Grupo 3), adaptados sobre o intermediário CeraOne fixado sobre uma base de latão de forma cilíndrica, medindo 4cm de comprimento x 2,5cm de diâmetro, contendo seis faces uniformes e numeradas. No centro, confeccionou-se uma perfuração com 4mm de diâmetro x 10mm de profundidade na qual foi fixado um implante de 10 x 3,75mm (Nobel Biocare). No CeraOne foi feita uma linha vertical e outra horizontal, a laser, em cada face do hexágono como referência de mensuração. Foram avaliados os ajustes antes e após a cimentação com o elastômero, com e sem vibração, constituindo três grupos de dez corpos de prova. Utilizou-se um microscópio comparador Mitutoyo (Japan) com aumento de 150 vezes para a leitura das medidas e com precisão de 1µm. Os resultados pelo teste de Fisher em nível de 5% de probabilidade demonstraram que o grupo mais estável foi o do cilindro de ouro, com coeficiente de variação de 29,43%; o grupo mais instável foi o grupo Procera All Ceran escaneado com coeficiente de variação de 106,50%. De acordo com a análise estatística do ajuste marginal dos componentes protéticos estéticos sobre o intermediário CeraOne, pôde-se concluir que: a) as três condições estudadas apresentaram valores de desajuste marginal estatisticamente semelhantes entre si; b) não houve diferença estatisticamente significante no ajuste com a utilização da vibração nas três condições experimentais estudadas.Made available in DSpace on 2015-09-14T10:14:10Z (GMT). No. of bitstreams: 1 dissertacao_jose_bernardes_das_neves.pdf: 1153052 bytes, checksum: 7f1c056a146003e1322e179bdf7a99aa (MD5) Previous issue date: 2005-02-15application/pdfporIASCJ - Universidade Sagrado CoraçãoImplantologiaUSCBRCiências da Saúde e BiológicasRESTAURAÇÃO DENTÁRIAPRÓTESES DE CERÂMICAODONTOLOGIA-ESTÉTICADENTAL RESTORATIONPROSTHESIS OF CERAMICSAESTHETIC DENTISTRYCIENCIAS DA SAUDE::ODONTOLOGIAAvaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraoneEvaluation of marginal adjustment of prosthetic components on aesthetic intermediary ceraoneinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis1715202039863940245600600600-753428887677182963-2070498469879244349info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da USCinstname:Universidade do Sagrado Coração (USC)instacron:USCORIGINALdissertacao_jose_bernardes_das_neves.pdfapplication/pdf1153052http://localhost:8080/tede/bitstream/tede/71/1/dissertacao_jose_bernardes_das_neves.pdf7f1c056a146003e1322e179bdf7a99aaMD51tede/712015-10-16 16:33:05.789oai:localhost:tede/71Biblioteca Digital de Teses e Dissertaçõeshttps://tede2.usc.br:8443/http://tede2.usc.br:8080/oai/requestbiblicorjesu@unisagrado.edu.br||normalizacao@usc.bropendoar:2015-10-16T19:33:05Biblioteca Digital de Teses e Dissertações da USC - Universidade do Sagrado Coração (USC)false
dc.title.por.fl_str_mv Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone
dc.title.alternative.eng.fl_str_mv Evaluation of marginal adjustment of prosthetic components on aesthetic intermediary ceraone
title Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone
spellingShingle Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone
Neves, José Bernardes das
RESTAURAÇÃO DENTÁRIA
PRÓTESES DE CERÂMICA
ODONTOLOGIA-ESTÉTICA
DENTAL RESTORATION
PROSTHESIS OF CERAMICS
AESTHETIC DENTISTRY
CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone
title_full Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone
title_fullStr Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone
title_full_unstemmed Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone
title_sort Avaliação do ajuste marginal de componentes protéticos estéticos sobre intermediário ceraone
author Neves, José Bernardes das
author_facet Neves, José Bernardes das
author_role author
dc.contributor.advisor1.fl_str_mv Francischone, Carlos Eduardo
dc.contributor.advisor1ID.fl_str_mv CPF:55930034834
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/5622847033913614
dc.contributor.authorID.fl_str_mv CPF:30056934653
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/5712704809420184
dc.contributor.author.fl_str_mv Neves, José Bernardes das
contributor_str_mv Francischone, Carlos Eduardo
dc.subject.por.fl_str_mv RESTAURAÇÃO DENTÁRIA
PRÓTESES DE CERÂMICA
ODONTOLOGIA-ESTÉTICA
topic RESTAURAÇÃO DENTÁRIA
PRÓTESES DE CERÂMICA
ODONTOLOGIA-ESTÉTICA
DENTAL RESTORATION
PROSTHESIS OF CERAMICS
AESTHETIC DENTISTRY
CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv DENTAL RESTORATION
PROSTHESIS OF CERAMICS
AESTHETIC DENTISTRY
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::ODONTOLOGIA
description The search for aesthetics in single implant restoration has increasingly prioritized the use of pure ceramics components in order to try and substitute the use of the metal-ceramic crowns. A number of techniques and materials have been developed with the purpose to overcome the difficulties in the attainment of prosthesis in pure ceramics or either, prostheses that present, beyond the aesthetic quality of conventional ceramics, resistance mechanics and adequate marginal adaptation. The success of the single prosthetic restoration, supported by osseointegrated implants and the health of the surrounding tissues, is closely related to the precision and the adaptation of the components and the stability of the interface / abutment / prostheses pillar. The Brãnemark system, in the 90 s presented, the CeraOne abutment as a solution for the single tooth losses that consist of modifications and adaptations of the screwed prosthesis for the cemented restoration. Ten gold cylinders (Group 1), ten coping of alumina oxide (Group 2) and ten of Procera scanned All Ceram (Group 3), adapted on a brass base of cylindrical form, measuring 4cm of length x 2,5cm of diameter, contend six faces numbered and uniforms, were used as test body. In the center, one perforation with 4mm of diameter x 10mm of depth was confectioned in which was fixed an implants of 10 x 3,75mm (Nobel Biocare). In the CeraOne a vertical and horizontal laser marks were drawn in each face of the hexagon as a reference. The fits had been evaluated before and after the face-hardenings with the elastomer, with and without vibration, constituting three groups of ten bodies of each test. A comparing microscope Mitutoyo (Japan) was used with increase of 150 times for the reading of the measures and with precision of 1µm. The results for the test of Fisher in level of 5% of probability demonstrate that the group most steady was of the gold cylinder, with coefficient of 29, 43% variation; the group most unstable was the group of Procera All Ceram scanned with coefficient of 106,50% variation. In accordance with the statistic analysis of the fit marginal of the aesthetic prostheses, it could be concluded that: a) the three studied conditions (gold cilinder, coping of alumina oxide premachined and coping of alumina scanned) have shown statistically similar results amongst them regarding the values of marginal fit; b) it did not have statistics significant difference in the reduction of the fit with the utilization of vibration, in the three studied experimental conditions.
publishDate 2005
dc.date.issued.fl_str_mv 2005-02-15
dc.date.available.fl_str_mv 2008-10-14
dc.date.accessioned.fl_str_mv 2015-09-14T10:14:10Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv NEVES, José Bernardes das. Evaluation of marginal adjustment of prosthetic components on aesthetic intermediary ceraone. 2005. 158 f. Dissertação (Mestrado em Biologia Oral - Implantologia) - IASCJ - Universidade Sagrado Coração, Bauru, 2005.
dc.identifier.uri.fl_str_mv http://localhost:8080/tede/handle/tede/71
identifier_str_mv NEVES, José Bernardes das. Evaluation of marginal adjustment of prosthetic components on aesthetic intermediary ceraone. 2005. 158 f. Dissertação (Mestrado em Biologia Oral - Implantologia) - IASCJ - Universidade Sagrado Coração, Bauru, 2005.
url http://localhost:8080/tede/handle/tede/71
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv 1715202039863940245
dc.relation.confidence.fl_str_mv 600
600
600
dc.relation.department.fl_str_mv -753428887677182963
dc.relation.cnpq.fl_str_mv -2070498469879244349
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv IASCJ - Universidade Sagrado Coração
dc.publisher.program.fl_str_mv Implantologia
dc.publisher.initials.fl_str_mv USC
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ciências da Saúde e Biológicas
publisher.none.fl_str_mv IASCJ - Universidade Sagrado Coração
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da USC
instname:Universidade do Sagrado Coração (USC)
instacron:USC
instname_str Universidade do Sagrado Coração (USC)
instacron_str USC
institution USC
reponame_str Biblioteca Digital de Teses e Dissertações da USC
collection Biblioteca Digital de Teses e Dissertações da USC
bitstream.url.fl_str_mv http://localhost:8080/tede/bitstream/tede/71/1/dissertacao_jose_bernardes_das_neves.pdf
bitstream.checksum.fl_str_mv 7f1c056a146003e1322e179bdf7a99aa
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USC - Universidade do Sagrado Coração (USC)
repository.mail.fl_str_mv biblicorjesu@unisagrado.edu.br||normalizacao@usc.br
_version_ 1800410544010690560