Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Tipo de documento: | Tese |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da USC |
Texto Completo: | http://tede2.usc.br:8080/jspui/handle/tede/417 |
Resumo: | The aim of this study was to evaluate the biomechanical behavior of 5 different fixation materials for the Bilateral Sagittal Split Osteotomy (BSSO) using miniplates and monocortical screws, in a 10-mm advancement and 20º counterclockwise rotation. Fixation materials were adapted bilaterally in the osteotomy site, according to 5 models: Model M1: one straight 4-hole miniplate and 4 monocortical screws; Model M2: two 4-hole straight miniplates and 8 monocortical screws; Model M3: one 10-hole double miniplate with two bridges and 10 monocortical screws; Model M4: one 8-hole 20º angled double miniplate with two bridges and 8 monocortical screws; Model M5: one semi-curve 6-hole miniplate and 6 monocortical screws. Two loading patterns were applied in each model: 100 N load in the posterior region, and 50 N load in the anterior region. Bone segments displacement and highest stress values in plates and screws were recorded. Highest displacement mesurements were recorded in M1 model (1,409 mm), while M2 model recorded lowest values when considering the posterior (0,446 mm) and anterior (0,481 mm) loads; M1 model (1209,2 MPa) recorded the highest stress peaks in screws; M1 (1067,9 MPa) and M3 (1479,2 MPa) recorded the highest stress peaks in plates, while the M5 model recorded the smallest peaks (387,3 MPa). The results suggest that the M1 and M3 models are those with the worst biomechanical behavior, while the M2 model is the most stable, and the M5 model with the best load distribution. |
id |
USC_7fdaf16ebb284a1dcb3f9ccb03441842 |
---|---|
oai_identifier_str |
oai:localhost:tede/417 |
network_acronym_str |
USC |
network_name_str |
Biblioteca Digital de Teses e Dissertações da USC |
repository_id_str |
|
spelling |
Ribeiro-Junior, Paulo Domingos505.245579.986.041-15http://lattes.cnpq.br/234953491091391913971281080.373.066-74http://lattes.cnpq.br/2496201979579604Mendes, Gabriel Cury Batista2018-06-21T17:50:20Z2018-04-19MENDES, Gabriel Cury Batista. Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos. 2018. 104 f. Tese (Doutorado em Biologia Oral - Área de Concentração: Cirurgia e Traumatologia Bucomaxilofacial) - Universidade do Sagrado Coração, Bauru, 2018.http://tede2.usc.br:8080/jspui/handle/tede/417The aim of this study was to evaluate the biomechanical behavior of 5 different fixation materials for the Bilateral Sagittal Split Osteotomy (BSSO) using miniplates and monocortical screws, in a 10-mm advancement and 20º counterclockwise rotation. Fixation materials were adapted bilaterally in the osteotomy site, according to 5 models: Model M1: one straight 4-hole miniplate and 4 monocortical screws; Model M2: two 4-hole straight miniplates and 8 monocortical screws; Model M3: one 10-hole double miniplate with two bridges and 10 monocortical screws; Model M4: one 8-hole 20º angled double miniplate with two bridges and 8 monocortical screws; Model M5: one semi-curve 6-hole miniplate and 6 monocortical screws. Two loading patterns were applied in each model: 100 N load in the posterior region, and 50 N load in the anterior region. Bone segments displacement and highest stress values in plates and screws were recorded. Highest displacement mesurements were recorded in M1 model (1,409 mm), while M2 model recorded lowest values when considering the posterior (0,446 mm) and anterior (0,481 mm) loads; M1 model (1209,2 MPa) recorded the highest stress peaks in screws; M1 (1067,9 MPa) and M3 (1479,2 MPa) recorded the highest stress peaks in plates, while the M5 model recorded the smallest peaks (387,3 MPa). The results suggest that the M1 and M3 models are those with the worst biomechanical behavior, while the M2 model is the most stable, and the M5 model with the best load distribution.O objetivo deste estudo foi avaliar, por meio de análise de elementos finitos, o comportamento biomecânico de 5 diferentes tipos de fixação da Osteotomia Sagital do Ramo Mandibular (OSRM) utilizando placas e parafusos monocorticais, em movimento de avanço de 10 mm e rotação anti-horária de 20º. Os materiais de osteossíntese foram adaptados na região da osteotomia bilateralmente, de acordo com os modelos: Modelo M1: uma miniplaca reta de 4 furos e 4 parafusos monocorticais; Modelo M2: duas miniplacas retas com 4 furos cada e 8 parafusos monocorticais; Modelo M3: uma miniplaca dupla de 10 furos com 2 pontes e 10 parafusos monocorticais; Modelo M4: uma miniplaca dupla angulada 20º de 8 furos com duas pontes e 8 parafusos monocorticais; Modelo M5: uma miniplaca semi-curva de 6 furos não lineares e 6 parafusos monocorticais. Dois padrões de carga foram aplicados em cada modelo: carga de 100 N na região posterior (oclusal dos dentes 45, 46 e 47), e carga de 50 N na região anterior (incisal dos dentes 31, 32, 41, 42). Os valores de deslocamento dos segmentos ósseos e os picos de tensão nas placas e parafusos foram registrados. Como resultados, obteve-se: maiores valores de deslocamento no modelo M1 (1,409 mm), enquanto o modelo M2 obteve os menores valores se considerado as cargas posterior (0,446 mm) e anterior (0,481 mm); o modelo M1 (1209,2 MPa) obteve os maiores picos de tensão nos parafusos; maiores picos de tensão nas placas nos modelos M1 (1067,9 MPa) e M3 (1479,2 MPa), enquanto o modelo M5 obteve os menores picos (387,3 MPa). Os resultados sugerem que os modelos M1 e M3 são os de pior comportamento biomecânico, enquanto o modelo M2 se mostrou o mais resistente ao deslocamento, sendo o modelo M5 o com melhor distribuição de cargas.Submitted by Laudeceia Machado (laudeceia.machado@usc.br) on 2018-06-20T22:19:17Z No. of bitstreams: 1 Avaliacao de 5 tipos de fixacao da osteotomia sagital dos ramos mandibulares em grandes avancos com rotacao anti - horaria... (219790).pdf: 6823561 bytes, checksum: 75680334673e0cce178502e178490a59 (MD5)Approved for entry into archive by Laudeceia Machado (laudeceia.machado@usc.br) on 2018-06-20T22:56:57Z (GMT) No. of bitstreams: 1 Avaliacao de 5 tipos de fixacao da osteotomia sagital dos ramos mandibulares em grandes avancos com rotacao anti - horaria... (219790).pdf: 6823561 bytes, checksum: 75680334673e0cce178502e178490a59 (MD5)Approved for entry into archive by Laudeceia Machado (laudeceia.machado@usc.br) on 2018-06-21T17:50:20Z (GMT) No. of bitstreams: 1 Avaliacao de 5 tipos de fixacao da osteotomia sagital dos ramos mandibulares em grandes avancos com rotacao anti - horaria... (219790).pdf: 6823561 bytes, checksum: 75680334673e0cce178502e178490a59 (MD5)Made available in DSpace on 2018-06-21T17:50:20Z (GMT). No. of bitstreams: 1 Avaliacao de 5 tipos de fixacao da osteotomia sagital dos ramos mandibulares em grandes avancos com rotacao anti - horaria... (219790).pdf: 6823561 bytes, checksum: 75680334673e0cce178502e178490a59 (MD5) Previous issue date: 2018-04-19Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESapplication/pdfporUniversidade do Sagrado CoraçãoCirurgia BucomaxilofacialUSCBrasilCiências da Saúde e BiológicasCirurgia ortognáticaPlacas ósseasOsteotomia sagital do ramo mandibularAnálise de elementos finitosOrthognathic surgeryBone platesSagittal splitt ramus osteotomyFinite element analysisODONTOLOGIA::CIRURGIA BUCO-MAXILO-FACIALAvaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitosEvaluation of 5 types of fixation of the sagittal osteotomy of the mandibular branches in great advances with anti-clockwise rotation: a finite element analysisinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-6325264627946202213600600600600-75342888767718296364815030238221912792075167498588264571info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da USCinstname:Universidade do Sagrado Coração (USC)instacron:USCORIGINALAvaliacao de 5 tipos de fixacao da osteotomia sagital dos ramos mandibulares em grandes avancos com rotacao anti - horaria... (219790).pdfAvaliacao de 5 tipos de fixacao da osteotomia sagital dos ramos mandibulares em grandes avancos com rotacao anti - horaria... (219790).pdfapplication/pdf6823561http://localhost:8080/tede/bitstream/tede/417/2/Avaliacao+de+5+tipos+de+fixacao+da+osteotomia+sagital+dos+ramos+mandibulares+em+grandes+avancos+com+rotacao+anti+-+horaria...+%28219790%29.pdf75680334673e0cce178502e178490a59MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://localhost:8080/tede/bitstream/tede/417/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede/4172018-06-21 14:50:20.699oai:localhost: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Biblioteca Digital de Teses e Dissertaçõeshttps://tede2.usc.br:8443/http://tede2.usc.br:8080/oai/requestbiblicorjesu@unisagrado.edu.br||normalizacao@usc.bropendoar:2018-06-21T17:50:20Biblioteca Digital de Teses e Dissertações da USC - Universidade do Sagrado Coração (USC)false |
dc.title.eng.fl_str_mv |
Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos |
dc.title.alternative.eng.fl_str_mv |
Evaluation of 5 types of fixation of the sagittal osteotomy of the mandibular branches in great advances with anti-clockwise rotation: a finite element analysis |
title |
Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos |
spellingShingle |
Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos Mendes, Gabriel Cury Batista Cirurgia ortognática Placas ósseas Osteotomia sagital do ramo mandibular Análise de elementos finitos Orthognathic surgery Bone plates Sagittal splitt ramus osteotomy Finite element analysis ODONTOLOGIA::CIRURGIA BUCO-MAXILO-FACIAL |
title_short |
Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos |
title_full |
Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos |
title_fullStr |
Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos |
title_full_unstemmed |
Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos |
title_sort |
Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos |
author |
Mendes, Gabriel Cury Batista |
author_facet |
Mendes, Gabriel Cury Batista |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Ribeiro-Junior, Paulo Domingos |
dc.contributor.advisor1ID.fl_str_mv |
505.245 579.986.041-15 |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/2349534910913919 |
dc.contributor.authorID.fl_str_mv |
13971281 080.373.066-74 |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/2496201979579604 |
dc.contributor.author.fl_str_mv |
Mendes, Gabriel Cury Batista |
contributor_str_mv |
Ribeiro-Junior, Paulo Domingos |
dc.subject.por.fl_str_mv |
Cirurgia ortognática Placas ósseas Osteotomia sagital do ramo mandibular Análise de elementos finitos |
topic |
Cirurgia ortognática Placas ósseas Osteotomia sagital do ramo mandibular Análise de elementos finitos Orthognathic surgery Bone plates Sagittal splitt ramus osteotomy Finite element analysis ODONTOLOGIA::CIRURGIA BUCO-MAXILO-FACIAL |
dc.subject.eng.fl_str_mv |
Orthognathic surgery Bone plates Sagittal splitt ramus osteotomy Finite element analysis |
dc.subject.cnpq.fl_str_mv |
ODONTOLOGIA::CIRURGIA BUCO-MAXILO-FACIAL |
description |
The aim of this study was to evaluate the biomechanical behavior of 5 different fixation materials for the Bilateral Sagittal Split Osteotomy (BSSO) using miniplates and monocortical screws, in a 10-mm advancement and 20º counterclockwise rotation. Fixation materials were adapted bilaterally in the osteotomy site, according to 5 models: Model M1: one straight 4-hole miniplate and 4 monocortical screws; Model M2: two 4-hole straight miniplates and 8 monocortical screws; Model M3: one 10-hole double miniplate with two bridges and 10 monocortical screws; Model M4: one 8-hole 20º angled double miniplate with two bridges and 8 monocortical screws; Model M5: one semi-curve 6-hole miniplate and 6 monocortical screws. Two loading patterns were applied in each model: 100 N load in the posterior region, and 50 N load in the anterior region. Bone segments displacement and highest stress values in plates and screws were recorded. Highest displacement mesurements were recorded in M1 model (1,409 mm), while M2 model recorded lowest values when considering the posterior (0,446 mm) and anterior (0,481 mm) loads; M1 model (1209,2 MPa) recorded the highest stress peaks in screws; M1 (1067,9 MPa) and M3 (1479,2 MPa) recorded the highest stress peaks in plates, while the M5 model recorded the smallest peaks (387,3 MPa). The results suggest that the M1 and M3 models are those with the worst biomechanical behavior, while the M2 model is the most stable, and the M5 model with the best load distribution. |
publishDate |
2018 |
dc.date.accessioned.fl_str_mv |
2018-06-21T17:50:20Z |
dc.date.issued.fl_str_mv |
2018-04-19 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
MENDES, Gabriel Cury Batista. Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos. 2018. 104 f. Tese (Doutorado em Biologia Oral - Área de Concentração: Cirurgia e Traumatologia Bucomaxilofacial) - Universidade do Sagrado Coração, Bauru, 2018. |
dc.identifier.uri.fl_str_mv |
http://tede2.usc.br:8080/jspui/handle/tede/417 |
identifier_str_mv |
MENDES, Gabriel Cury Batista. Avaliação de 5 tipos de fixação da osteotomia sagital dos ramos mandibulares em grandes avanços com rotação anti-horária: uma análise de elementos finitos. 2018. 104 f. Tese (Doutorado em Biologia Oral - Área de Concentração: Cirurgia e Traumatologia Bucomaxilofacial) - Universidade do Sagrado Coração, Bauru, 2018. |
url |
http://tede2.usc.br:8080/jspui/handle/tede/417 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.program.fl_str_mv |
-6325264627946202213 |
dc.relation.confidence.fl_str_mv |
600 600 600 600 |
dc.relation.department.fl_str_mv |
-753428887677182963 |
dc.relation.cnpq.fl_str_mv |
6481503023822191279 |
dc.relation.sponsorship.fl_str_mv |
2075167498588264571 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade do Sagrado Coração |
dc.publisher.program.fl_str_mv |
Cirurgia Bucomaxilofacial |
dc.publisher.initials.fl_str_mv |
USC |
dc.publisher.country.fl_str_mv |
Brasil |
dc.publisher.department.fl_str_mv |
Ciências da Saúde e Biológicas |
publisher.none.fl_str_mv |
Universidade do Sagrado Coração |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da USC instname:Universidade do Sagrado Coração (USC) instacron:USC |
instname_str |
Universidade do Sagrado Coração (USC) |
instacron_str |
USC |
institution |
USC |
reponame_str |
Biblioteca Digital de Teses e Dissertações da USC |
collection |
Biblioteca Digital de Teses e Dissertações da USC |
bitstream.url.fl_str_mv |
http://localhost:8080/tede/bitstream/tede/417/2/Avaliacao+de+5+tipos+de+fixacao+da+osteotomia+sagital+dos+ramos+mandibulares+em+grandes+avancos+com+rotacao+anti+-+horaria...+%28219790%29.pdf http://localhost:8080/tede/bitstream/tede/417/1/license.txt |
bitstream.checksum.fl_str_mv |
75680334673e0cce178502e178490a59 bd3efa91386c1718a7f26a329fdcb468 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da USC - Universidade do Sagrado Coração (USC) |
repository.mail.fl_str_mv |
biblicorjesu@unisagrado.edu.br||normalizacao@usc.br |
_version_ |
1815438146301591552 |