Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/3223 |
Resumo: | AIMS: All materials added to teeth should present an adequate radiopacity to allow the detection of secondary caries. Usually, in extensive cavities, base materials like calcium hydroxide cement are used for the purpose of protecting the pulp. In an attempt to improve the efficiency of radiographic detection of this material, this study aimed to determine the radiopacity of three calcium hydroxide cements and to compare the radiopacity of these materials with dentin and enamel. METHODS: Radiographs were taken of 1-mm thick specimens of three calcium hydroxide cements: Hydro-C, Dycal and Life, an aluminium stepwedge, a lead foil, and one 1-mm thick human tooth slice. Densitometric measurements were obtained after radiographic processing. The radiopacity values of the calcium hydroxide cements, dentin and enamel were expressed in terms of the equivalent thickness of aluminium. RESULTS: The analysis of variance indicated statistically significant difference only for Life, which presented the lowest radiopacity when compared to the other cements. However, all cements and enamel possessed a radiopacity equivalent to 2mm Al, while dentin presented a radiopacity equivalent to 1mm Al. CONCLUSION: All tested cements presented a similar radiopacity to that of enamel and they meet the ISO 4049 specifications. |
id |
USP-17_0c2b6ab55cdeb02054160f51353bce71 |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/3223 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas Radiopacity of calcium hydroxide cement compared with human tooth structure RadiopacidadeCimento de hidróxido de cálcioEsmalteDentinaRadiopacityCalcium hydroxide cementEnamelDentin AIMS: All materials added to teeth should present an adequate radiopacity to allow the detection of secondary caries. Usually, in extensive cavities, base materials like calcium hydroxide cement are used for the purpose of protecting the pulp. In an attempt to improve the efficiency of radiographic detection of this material, this study aimed to determine the radiopacity of three calcium hydroxide cements and to compare the radiopacity of these materials with dentin and enamel. METHODS: Radiographs were taken of 1-mm thick specimens of three calcium hydroxide cements: Hydro-C, Dycal and Life, an aluminium stepwedge, a lead foil, and one 1-mm thick human tooth slice. Densitometric measurements were obtained after radiographic processing. The radiopacity values of the calcium hydroxide cements, dentin and enamel were expressed in terms of the equivalent thickness of aluminium. RESULTS: The analysis of variance indicated statistically significant difference only for Life, which presented the lowest radiopacity when compared to the other cements. However, all cements and enamel possessed a radiopacity equivalent to 2mm Al, while dentin presented a radiopacity equivalent to 1mm Al. CONCLUSION: All tested cements presented a similar radiopacity to that of enamel and they meet the ISO 4049 specifications. OBJETIVOS: Todos os materiais adicionados aos dentes deveriam apresentar uma adequada radiopacidade para permitir a detecção de cáries secundárias. Geralmente em cavidades extensas, materiais de base, como o cimento de hidróxido de cálcio, são usados com a função de proteger a polpa. Na tentativa de melhorar a eficiência na detecção radiográfica deste material, este estudo foi realizado com o objetivo de determinar a radiopacidade de três cimentos de hidróxido de cálcio e comparar a radiopacidade destes materiais com a da dentina e do esmalte. MATERIAIS E MÉTODO: Foram radiografados corpos de prova de 1 mm de espessura de três cimentos de hidróxido de cálcio: Hydro-C, Dycal e Life, uma escala de densidade de alumínio, uma lâmina de chumbo e um corte de dente humano de 1 mm de espessura. As densidades ópticas foram obtidas após o processamento radiográfico. Os valores de radiopacidade dos cimentos de hidróxido de cálcio, dentina e esmalte foram expressos em espessuras equivalentes de alumínio. RESULTADOS: A análise de variância indicou diferença estatisticamente significativa apenas para o cimento Life que apresentou a menor radiopacidade quando comparado aos outros cimentos. Entretanto, todos os cimentos e o esmalte possuíram uma radiopacidade equivalente a 2 mm de Al, enquanto a dentina apresentava radiopacidade equivalente a 1 mm de Al. CONCLUSÃO: Todos os cimentos testados apresentaram radiopacidades semelhantes à do esmalte, estando de acordo com as especificações da ISO 4049. Universidade de São Paulo. Faculdade de Odontologia de Bauru2004-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/322310.1590/S1678-77572004000400007Journal of Applied Oral Science; Vol. 12 No. 4 (2004); 290-293 Journal of Applied Oral Science; Vol. 12 Núm. 4 (2004); 290-293 Journal of Applied Oral Science; v. 12 n. 4 (2004); 290-293 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3223/3913Copyright (c) 2004 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessDevito, Karina LopesOrtega, Ana IsabelHaiter-Neto, Francisco2012-04-27T11:48:40Zoai:revistas.usp.br:article/3223Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:48:40Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas Radiopacity of calcium hydroxide cement compared with human tooth structure |
title |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas |
spellingShingle |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas Devito, Karina Lopes Radiopacidade Cimento de hidróxido de cálcio Esmalte Dentina Radiopacity Calcium hydroxide cement Enamel Dentin |
title_short |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas |
title_full |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas |
title_fullStr |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas |
title_full_unstemmed |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas |
title_sort |
Radiopacidade do cimento de hidróxido de cálcio comparada a das estruturas dentais humanas |
author |
Devito, Karina Lopes |
author_facet |
Devito, Karina Lopes Ortega, Ana Isabel Haiter-Neto, Francisco |
author_role |
author |
author2 |
Ortega, Ana Isabel Haiter-Neto, Francisco |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Devito, Karina Lopes Ortega, Ana Isabel Haiter-Neto, Francisco |
dc.subject.por.fl_str_mv |
Radiopacidade Cimento de hidróxido de cálcio Esmalte Dentina Radiopacity Calcium hydroxide cement Enamel Dentin |
topic |
Radiopacidade Cimento de hidróxido de cálcio Esmalte Dentina Radiopacity Calcium hydroxide cement Enamel Dentin |
description |
AIMS: All materials added to teeth should present an adequate radiopacity to allow the detection of secondary caries. Usually, in extensive cavities, base materials like calcium hydroxide cement are used for the purpose of protecting the pulp. In an attempt to improve the efficiency of radiographic detection of this material, this study aimed to determine the radiopacity of three calcium hydroxide cements and to compare the radiopacity of these materials with dentin and enamel. METHODS: Radiographs were taken of 1-mm thick specimens of three calcium hydroxide cements: Hydro-C, Dycal and Life, an aluminium stepwedge, a lead foil, and one 1-mm thick human tooth slice. Densitometric measurements were obtained after radiographic processing. The radiopacity values of the calcium hydroxide cements, dentin and enamel were expressed in terms of the equivalent thickness of aluminium. RESULTS: The analysis of variance indicated statistically significant difference only for Life, which presented the lowest radiopacity when compared to the other cements. However, all cements and enamel possessed a radiopacity equivalent to 2mm Al, while dentin presented a radiopacity equivalent to 1mm Al. CONCLUSION: All tested cements presented a similar radiopacity to that of enamel and they meet the ISO 4049 specifications. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3223 10.1590/S1678-77572004000400007 |
url |
https://www.revistas.usp.br/jaos/article/view/3223 |
identifier_str_mv |
10.1590/S1678-77572004000400007 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3223/3913 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2004 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2004 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 12 No. 4 (2004); 290-293 Journal of Applied Oral Science; Vol. 12 Núm. 4 (2004); 290-293 Journal of Applied Oral Science; v. 12 n. 4 (2004); 290-293 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1800221671418757120 |