Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study

Detalhes bibliográficos
Autor(a) principal: Ai-Ani, Alaa Jamal
Data de Publicação: 2024
Outros Autores: Taher, Hanan Jafer, Alalawi, Ammar Saleh
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/224183
Resumo: Oral soft tissue lesions require a precise diagnosis by oral biopsy with the ability to recognize these lesions within histopathological levels, so the instrument used for the incisions should be safe and cause little to no harm to the surrounding tissue. Objective: This study compared a dual-wavelength diode laser and an Er, Cr:YSGG laser in oral soft tissue incisions to determine the most effective and safest laser system at the histopathological level. Methodology: The (810 and 980 nm) dual-wavelength diode laser was used at 1.5 W and 2.5 W (CW) power settings, and the (2780 nm) Er, Cr:YSGG laser was used at 2.5 W and 3.5 W (PW) power settings. Both laser systems were used to incise the tissues of freshly dissected sheep tongue pieces to obtain the following histopathological criteria: epithelial tissue changes, connective tissue changes, and lateral thermal damage extent by optical microscopy. Results: The epithelial and connective tissue damage scores were significantly higher in the dual-wavelength diode laser groups than in the Er, Cr:YSGG laser groups (P<0.001), and there was a significant difference between some groups. The extent of lateral thermal damage was also significantly higher in the diode laser groups than in the Er, Cr: YSGG laser groups (P<0.001), and there was a significant difference between groups. Group 2 (2.5 W) of the diode laser was the highest for all three criteria, while group 3 (2.5 W) of the Er, Cr:YSGG laser was the lowest. Conclusion: The Er, Cr:YSGG laser with an output power of 2.5 W is, histologically, the most effective and safest laser for oral soft tissue incision. The dual-wavelength diode laser causes more damage than the Er, Cr:YSGG laser, but it can be used with a low output power and 1 mm safety distance in excisional biopsy.
id USP-17_333ee4eb121b04a934db3bb180a7042d
oai_identifier_str oai:revistas.usp.br:article/224183
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo studyErCr:YSGG laserDiode laserSoft tissueHistological labelingOral soft tissue lesions require a precise diagnosis by oral biopsy with the ability to recognize these lesions within histopathological levels, so the instrument used for the incisions should be safe and cause little to no harm to the surrounding tissue. Objective: This study compared a dual-wavelength diode laser and an Er, Cr:YSGG laser in oral soft tissue incisions to determine the most effective and safest laser system at the histopathological level. Methodology: The (810 and 980 nm) dual-wavelength diode laser was used at 1.5 W and 2.5 W (CW) power settings, and the (2780 nm) Er, Cr:YSGG laser was used at 2.5 W and 3.5 W (PW) power settings. Both laser systems were used to incise the tissues of freshly dissected sheep tongue pieces to obtain the following histopathological criteria: epithelial tissue changes, connective tissue changes, and lateral thermal damage extent by optical microscopy. Results: The epithelial and connective tissue damage scores were significantly higher in the dual-wavelength diode laser groups than in the Er, Cr:YSGG laser groups (P<0.001), and there was a significant difference between some groups. The extent of lateral thermal damage was also significantly higher in the diode laser groups than in the Er, Cr: YSGG laser groups (P<0.001), and there was a significant difference between groups. Group 2 (2.5 W) of the diode laser was the highest for all three criteria, while group 3 (2.5 W) of the Er, Cr:YSGG laser was the lowest. Conclusion: The Er, Cr:YSGG laser with an output power of 2.5 W is, histologically, the most effective and safest laser for oral soft tissue incision. The dual-wavelength diode laser causes more damage than the Er, Cr:YSGG laser, but it can be used with a low output power and 1 mm safety distance in excisional biopsy.Universidade de São Paulo. Faculdade de Odontologia de Bauru2024-04-22info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/22418310.1590/Journal of Applied Oral Science; Vol. 32 (2024); e20230419Journal of Applied Oral Science; v. 32 (2024); e20230419Journal of Applied Oral Science; Vol. 32 (2024); e202304191678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/224183/203845Copyright (c) 2024 Journal of Applied Oral Sciencehttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessAi-Ani, Alaa JamalTaher, Hanan JaferAlalawi, Ammar Saleh2024-04-22T14:01:38Zoai:revistas.usp.br:article/224183Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2024-04-22T14:01:38Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study
title Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study
spellingShingle Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study
Ai-Ani, Alaa Jamal
Er
Cr:YSGG laser
Diode laser
Soft tissue
Histological labeling
title_short Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study
title_full Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study
title_fullStr Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study
title_full_unstemmed Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study
title_sort Histological evaluation of the surgical margins of oral soft tissue incisions using a dual-wavelength diode laser and an Er, Cr:YSGG laser: an ex vivo study
author Ai-Ani, Alaa Jamal
author_facet Ai-Ani, Alaa Jamal
Taher, Hanan Jafer
Alalawi, Ammar Saleh
author_role author
author2 Taher, Hanan Jafer
Alalawi, Ammar Saleh
author2_role author
author
dc.contributor.author.fl_str_mv Ai-Ani, Alaa Jamal
Taher, Hanan Jafer
Alalawi, Ammar Saleh
dc.subject.por.fl_str_mv Er
Cr:YSGG laser
Diode laser
Soft tissue
Histological labeling
topic Er
Cr:YSGG laser
Diode laser
Soft tissue
Histological labeling
description Oral soft tissue lesions require a precise diagnosis by oral biopsy with the ability to recognize these lesions within histopathological levels, so the instrument used for the incisions should be safe and cause little to no harm to the surrounding tissue. Objective: This study compared a dual-wavelength diode laser and an Er, Cr:YSGG laser in oral soft tissue incisions to determine the most effective and safest laser system at the histopathological level. Methodology: The (810 and 980 nm) dual-wavelength diode laser was used at 1.5 W and 2.5 W (CW) power settings, and the (2780 nm) Er, Cr:YSGG laser was used at 2.5 W and 3.5 W (PW) power settings. Both laser systems were used to incise the tissues of freshly dissected sheep tongue pieces to obtain the following histopathological criteria: epithelial tissue changes, connective tissue changes, and lateral thermal damage extent by optical microscopy. Results: The epithelial and connective tissue damage scores were significantly higher in the dual-wavelength diode laser groups than in the Er, Cr:YSGG laser groups (P<0.001), and there was a significant difference between some groups. The extent of lateral thermal damage was also significantly higher in the diode laser groups than in the Er, Cr: YSGG laser groups (P<0.001), and there was a significant difference between groups. Group 2 (2.5 W) of the diode laser was the highest for all three criteria, while group 3 (2.5 W) of the Er, Cr:YSGG laser was the lowest. Conclusion: The Er, Cr:YSGG laser with an output power of 2.5 W is, histologically, the most effective and safest laser for oral soft tissue incision. The dual-wavelength diode laser causes more damage than the Er, Cr:YSGG laser, but it can be used with a low output power and 1 mm safety distance in excisional biopsy.
publishDate 2024
dc.date.none.fl_str_mv 2024-04-22
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/224183
10.1590/
url https://www.revistas.usp.br/jaos/article/view/224183
identifier_str_mv 10.1590/
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/224183/203845
dc.rights.driver.fl_str_mv Copyright (c) 2024 Journal of Applied Oral Science
http://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2024 Journal of Applied Oral Science
http://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 32 (2024); e20230419
Journal of Applied Oral Science; v. 32 (2024); e20230419
Journal of Applied Oral Science; Vol. 32 (2024); e20230419
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221670454067200