Use of base metal casting alloys for implant framework: marginal accuracy analysis

Detalhes bibliográficos
Autor(a) principal: Kano, Stefania Carvalho
Data de Publicação: 2004
Outros Autores: Bonfante, Gerson, Hussne, Raquel, Siqueira, Aline F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3232
Resumo: The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were examined for marginal accuracy according to: (A) vertical gap; (B) horizontal gap and (C) horizontal gap depth at the abutment/cylinder interface. Data were submitted to statistical analysis (ANOVA and Student-Newman Keuls, p
id USP-17_39f3f740c2cdd0af313dfd317fff0b13
oai_identifier_str oai:revistas.usp.br:article/3232
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Use of base metal casting alloys for implant framework: marginal accuracy analysis Uso de ligas metálicas básicas em próteses sobre implantes: análise da adaptação marginal Prótese sobre implantesLigas^i2^sajuImplant prosthesisAlloys^i1^smis The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were examined for marginal accuracy according to: (A) vertical gap; (B) horizontal gap and (C) horizontal gap depth at the abutment/cylinder interface. Data were submitted to statistical analysis (ANOVA and Student-Newman Keuls, p O protocolo para prótese sobre implantes recomenda o uso de uma infra-estrutura em ouro para próteses metalo-plásticas e metalo-cerâmicas. No entanto, devido ao seu alto custo, o uso de ligas alternativas é desejado. OBJETIVO: Este estudo compara a adaptação marginal de cilindros protéticos pré-fabricados e cilindros protéticos plásticos fundidos com dois tipos de ligas metálicas básicas. MATERIAL E MÉTODOS: 05 amostras de (1) cilindros plásticos fundidos em liga de cobalto cromo; (2) cilindros plásticos fundidos em liga de níquel cromo e (3) cilindros pré-fabricados com cinta metálica em paládio, foram examinados na interface intermediário/cilindro protético na análise de desajuste marginal, considerando-se (A) desajuste vertical, (B) desajuste horizontal e (C) profundidade de fenda. RESULTADOS: os valores médios para o desajuste vertical, horizontal e profundidade foram, respectivamente, 4,13µm, 14,5µm e 6,93µm para o cilindro pré-fabricado em paládio, 23,18µm, 33,2µm e 88µm para os cilindros plásticos fundidos em Níquel cromo e 25,6µm, 51,8µm e 114,54 µm para os cilindros fundidos em cobalto-cromo. CONCLUSÃO: não foram encontradas diferenças estatísticas entre os grupos fundidos (grupo 1 e 2), mas uma adaptação marginal significantemente superior foi observada com os cilindros pré-fabricados quando comparado aos cilindros plásticos fundidos com níquel-cromo e cobalto-cromo para todas as análises. Universidade de São Paulo. Faculdade de Odontologia de Bauru2004-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/323210.1590/S1678-77572004000400016Journal of Applied Oral Science; Vol. 12 No. 4 (2004); 337-343 Journal of Applied Oral Science; Vol. 12 Núm. 4 (2004); 337-343 Journal of Applied Oral Science; v. 12 n. 4 (2004); 337-343 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3232/3922Copyright (c) 2004 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessKano, Stefania CarvalhoBonfante, GersonHussne, RaquelSiqueira, Aline F.2012-04-27T11:49:00Zoai:revistas.usp.br:article/3232Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:49Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Use of base metal casting alloys for implant framework: marginal accuracy analysis
Uso de ligas metálicas básicas em próteses sobre implantes: análise da adaptação marginal
title Use of base metal casting alloys for implant framework: marginal accuracy analysis
spellingShingle Use of base metal casting alloys for implant framework: marginal accuracy analysis
Kano, Stefania Carvalho
Prótese sobre implantes
Ligas^i2^saju
Implant prosthesis
Alloys^i1^smis
title_short Use of base metal casting alloys for implant framework: marginal accuracy analysis
title_full Use of base metal casting alloys for implant framework: marginal accuracy analysis
title_fullStr Use of base metal casting alloys for implant framework: marginal accuracy analysis
title_full_unstemmed Use of base metal casting alloys for implant framework: marginal accuracy analysis
title_sort Use of base metal casting alloys for implant framework: marginal accuracy analysis
author Kano, Stefania Carvalho
author_facet Kano, Stefania Carvalho
Bonfante, Gerson
Hussne, Raquel
Siqueira, Aline F.
author_role author
author2 Bonfante, Gerson
Hussne, Raquel
Siqueira, Aline F.
author2_role author
author
author
dc.contributor.author.fl_str_mv Kano, Stefania Carvalho
Bonfante, Gerson
Hussne, Raquel
Siqueira, Aline F.
dc.subject.por.fl_str_mv Prótese sobre implantes
Ligas^i2^saju
Implant prosthesis
Alloys^i1^smis
topic Prótese sobre implantes
Ligas^i2^saju
Implant prosthesis
Alloys^i1^smis
description The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were examined for marginal accuracy according to: (A) vertical gap; (B) horizontal gap and (C) horizontal gap depth at the abutment/cylinder interface. Data were submitted to statistical analysis (ANOVA and Student-Newman Keuls, p
publishDate 2004
dc.date.none.fl_str_mv 2004-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3232
10.1590/S1678-77572004000400016
url https://www.revistas.usp.br/jaos/article/view/3232
identifier_str_mv 10.1590/S1678-77572004000400016
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3232/3922
dc.rights.driver.fl_str_mv Copyright (c) 2004 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2004 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 12 No. 4 (2004); 337-343
Journal of Applied Oral Science; Vol. 12 Núm. 4 (2004); 337-343
Journal of Applied Oral Science; v. 12 n. 4 (2004); 337-343
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221671967162368