Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/3559 |
Resumo: | The aims of this study were to evaluate the quality of indirect digitized radiographic images taken during endodontic procedures and to compare the measurements recorded with this technique to those obtained from conventional radiographs. Two-hundred conventional periapical radiographs taken at the undergraduate Endodontics Clinic of the Dental School of Bauru were digitized. The conventional and indirect digitized images were compared by three examiners as to the quality and accuracy of the measurements recorded during endodontic treatment, in canal length determination, gutta-percha adaptation, lateral condensation and final obturation. The conventional radiographs were observed on a film viewer, surrounded by a dark card, and measured with magnifying glass and a millimeter ruler; the indirect digitized images were evaluated on the Digora® for Windows software, with free utilization of the bright/contrast tool. Unlike the conventional radiographic images, all indirect digitized images were considered as having a high quality. The distance between the filling material and the root apex was 0.117 mm larger, on average, for the Digora® system (p |
id |
USP-17_4aa30323395be08fa39d84499d117267 |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/3559 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment RadiographyPhotostimulated phosphor plate systemDigora The aims of this study were to evaluate the quality of indirect digitized radiographic images taken during endodontic procedures and to compare the measurements recorded with this technique to those obtained from conventional radiographs. Two-hundred conventional periapical radiographs taken at the undergraduate Endodontics Clinic of the Dental School of Bauru were digitized. The conventional and indirect digitized images were compared by three examiners as to the quality and accuracy of the measurements recorded during endodontic treatment, in canal length determination, gutta-percha adaptation, lateral condensation and final obturation. The conventional radiographs were observed on a film viewer, surrounded by a dark card, and measured with magnifying glass and a millimeter ruler; the indirect digitized images were evaluated on the Digora® for Windows software, with free utilization of the bright/contrast tool. Unlike the conventional radiographic images, all indirect digitized images were considered as having a high quality. The distance between the filling material and the root apex was 0.117 mm larger, on average, for the Digora® system (pUniversidade de São Paulo. Faculdade de Odontologia de Bauru2008-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/355910.1590/S1678-77572008000200016Journal of Applied Oral Science; Vol. 16 No. 2 (2008); 167-170 Journal of Applied Oral Science; Vol. 16 Núm. 2 (2008); 167-170 Journal of Applied Oral Science; v. 16 n. 2 (2008); 167-170 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3559/4249Copyright (c) 2008 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessSchmitd, Ligia BulotoLima, Tatiana de CastroChinellato, Luiz Eduardo MontenegroBramante, Clóvis MonteiroGarcia, Roberto BrandãoMoraes, Ivaldo Gomes deBernardineli, Norberti2012-04-27T12:00:39Zoai:revistas.usp.br:article/3559Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T12:00:39Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment |
title |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment |
spellingShingle |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment Schmitd, Ligia Buloto Radiography Photostimulated phosphor plate system Digora |
title_short |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment |
title_full |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment |
title_fullStr |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment |
title_full_unstemmed |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment |
title_sort |
Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment |
author |
Schmitd, Ligia Buloto |
author_facet |
Schmitd, Ligia Buloto Lima, Tatiana de Castro Chinellato, Luiz Eduardo Montenegro Bramante, Clóvis Monteiro Garcia, Roberto Brandão Moraes, Ivaldo Gomes de Bernardineli, Norberti |
author_role |
author |
author2 |
Lima, Tatiana de Castro Chinellato, Luiz Eduardo Montenegro Bramante, Clóvis Monteiro Garcia, Roberto Brandão Moraes, Ivaldo Gomes de Bernardineli, Norberti |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Schmitd, Ligia Buloto Lima, Tatiana de Castro Chinellato, Luiz Eduardo Montenegro Bramante, Clóvis Monteiro Garcia, Roberto Brandão Moraes, Ivaldo Gomes de Bernardineli, Norberti |
dc.subject.por.fl_str_mv |
Radiography Photostimulated phosphor plate system Digora |
topic |
Radiography Photostimulated phosphor plate system Digora |
description |
The aims of this study were to evaluate the quality of indirect digitized radiographic images taken during endodontic procedures and to compare the measurements recorded with this technique to those obtained from conventional radiographs. Two-hundred conventional periapical radiographs taken at the undergraduate Endodontics Clinic of the Dental School of Bauru were digitized. The conventional and indirect digitized images were compared by three examiners as to the quality and accuracy of the measurements recorded during endodontic treatment, in canal length determination, gutta-percha adaptation, lateral condensation and final obturation. The conventional radiographs were observed on a film viewer, surrounded by a dark card, and measured with magnifying glass and a millimeter ruler; the indirect digitized images were evaluated on the Digora® for Windows software, with free utilization of the bright/contrast tool. Unlike the conventional radiographic images, all indirect digitized images were considered as having a high quality. The distance between the filling material and the root apex was 0.117 mm larger, on average, for the Digora® system (p |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3559 10.1590/S1678-77572008000200016 |
url |
https://www.revistas.usp.br/jaos/article/view/3559 |
identifier_str_mv |
10.1590/S1678-77572008000200016 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3559/4249 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2008 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2008 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 16 No. 2 (2008); 167-170 Journal of Applied Oral Science; Vol. 16 Núm. 2 (2008); 167-170 Journal of Applied Oral Science; v. 16 n. 2 (2008); 167-170 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1800221673930096640 |