Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars

Detalhes bibliográficos
Autor(a) principal: FERREIRA JÚNIOR,Osny
Data de Publicação: 2018
Outros Autores: MUNHOZ,Etiene Andrade, SEGANTIN,Jéssica de Fátima, GONÇALES,Eduardo Sanches, CARVALHO,Paulo Sérgio Perri de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572018000100485
Resumo: Abstract It is necessary to preserve height and thickness of the alveolar bone to facilitate rehabilitation with osteointegratable implants or simply to maintain bone integrity after extraction. Biomaterials associated with resorbable or non-resorbable membranes, when placed in the region of the socket, may contribute to avoid this unwanted reabsorption. Objective The objective of this study was to evaluate the distance of the crest of alveolar ridge to the cementoenamel junction (CEJ) of the lower second molars and the bone density of the third molar socket filled with Gen-Tech®, 5 years after an exodontia using cone beam computed tomography (CBCT) to visualize the central region of the sockets, without overlapping of the buccal and lingual cortical bones. Material and Methods A total of 12 individuals from an initial group of 39 patients submitted to extraction of the unruptured lower third molars and grafting of an association of inorganic bovine bone matrix, organic bovine bone matrix, collagen and bone morphogenetic proteins (BMP) (Gen-Tech®) on one side and the contralateral sockets filled only by clot, returned to control after 5 years, and were submitted to CBCT. The distance from the crest of alveolar bone to the CEJ and the bone density (BD) were measured using the i-CAT Vision Software. Results The results showed that the distance from the crest of alveolar bone to the CEJ in the control group was similar to that observed before the exodontia; in the experimental group, this distance was smaller. Considering the BD measurement, a significantly higher density was observed in the experimental group (p<0.05). Conclusion Part of the biomaterial was not absorbed and allowed the stability of the evaluated parameters after 5 years, being able to be used as a bone substitute in the socket.
id USP-17_4aca4b2d006c715176ef7becabca5732
oai_identifier_str oai:scielo:S1678-77572018000100485
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molarsTomographyHeterograftsThird molarBone regenerationAbstract It is necessary to preserve height and thickness of the alveolar bone to facilitate rehabilitation with osteointegratable implants or simply to maintain bone integrity after extraction. Biomaterials associated with resorbable or non-resorbable membranes, when placed in the region of the socket, may contribute to avoid this unwanted reabsorption. Objective The objective of this study was to evaluate the distance of the crest of alveolar ridge to the cementoenamel junction (CEJ) of the lower second molars and the bone density of the third molar socket filled with Gen-Tech®, 5 years after an exodontia using cone beam computed tomography (CBCT) to visualize the central region of the sockets, without overlapping of the buccal and lingual cortical bones. Material and Methods A total of 12 individuals from an initial group of 39 patients submitted to extraction of the unruptured lower third molars and grafting of an association of inorganic bovine bone matrix, organic bovine bone matrix, collagen and bone morphogenetic proteins (BMP) (Gen-Tech®) on one side and the contralateral sockets filled only by clot, returned to control after 5 years, and were submitted to CBCT. The distance from the crest of alveolar bone to the CEJ and the bone density (BD) were measured using the i-CAT Vision Software. Results The results showed that the distance from the crest of alveolar bone to the CEJ in the control group was similar to that observed before the exodontia; in the experimental group, this distance was smaller. Considering the BD measurement, a significantly higher density was observed in the experimental group (p<0.05). Conclusion Part of the biomaterial was not absorbed and allowed the stability of the evaluated parameters after 5 years, being able to be used as a bone substitute in the socket.Faculdade De Odontologia De Bauru - USP2018-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572018000100485Journal of Applied Oral Science v.26 2018reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/1678-7757-2017-0396info:eu-repo/semantics/openAccessFERREIRA JÚNIOR,OsnyMUNHOZ,Etiene AndradeSEGANTIN,Jéssica de FátimaGONÇALES,Eduardo SanchesCARVALHO,Paulo Sérgio Perri deeng2018-07-13T00:00:00Zoai:scielo:S1678-77572018000100485Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2018-07-13T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars
title Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars
spellingShingle Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars
FERREIRA JÚNIOR,Osny
Tomography
Heterografts
Third molar
Bone regeneration
title_short Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars
title_full Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars
title_fullStr Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars
title_full_unstemmed Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars
title_sort Tomographic late evaluation of xenogeneic bone grafts in sockets of impacted third molars
author FERREIRA JÚNIOR,Osny
author_facet FERREIRA JÚNIOR,Osny
MUNHOZ,Etiene Andrade
SEGANTIN,Jéssica de Fátima
GONÇALES,Eduardo Sanches
CARVALHO,Paulo Sérgio Perri de
author_role author
author2 MUNHOZ,Etiene Andrade
SEGANTIN,Jéssica de Fátima
GONÇALES,Eduardo Sanches
CARVALHO,Paulo Sérgio Perri de
author2_role author
author
author
author
dc.contributor.author.fl_str_mv FERREIRA JÚNIOR,Osny
MUNHOZ,Etiene Andrade
SEGANTIN,Jéssica de Fátima
GONÇALES,Eduardo Sanches
CARVALHO,Paulo Sérgio Perri de
dc.subject.por.fl_str_mv Tomography
Heterografts
Third molar
Bone regeneration
topic Tomography
Heterografts
Third molar
Bone regeneration
description Abstract It is necessary to preserve height and thickness of the alveolar bone to facilitate rehabilitation with osteointegratable implants or simply to maintain bone integrity after extraction. Biomaterials associated with resorbable or non-resorbable membranes, when placed in the region of the socket, may contribute to avoid this unwanted reabsorption. Objective The objective of this study was to evaluate the distance of the crest of alveolar ridge to the cementoenamel junction (CEJ) of the lower second molars and the bone density of the third molar socket filled with Gen-Tech®, 5 years after an exodontia using cone beam computed tomography (CBCT) to visualize the central region of the sockets, without overlapping of the buccal and lingual cortical bones. Material and Methods A total of 12 individuals from an initial group of 39 patients submitted to extraction of the unruptured lower third molars and grafting of an association of inorganic bovine bone matrix, organic bovine bone matrix, collagen and bone morphogenetic proteins (BMP) (Gen-Tech®) on one side and the contralateral sockets filled only by clot, returned to control after 5 years, and were submitted to CBCT. The distance from the crest of alveolar bone to the CEJ and the bone density (BD) were measured using the i-CAT Vision Software. Results The results showed that the distance from the crest of alveolar bone to the CEJ in the control group was similar to that observed before the exodontia; in the experimental group, this distance was smaller. Considering the BD measurement, a significantly higher density was observed in the experimental group (p<0.05). Conclusion Part of the biomaterial was not absorbed and allowed the stability of the evaluated parameters after 5 years, being able to be used as a bone substitute in the socket.
publishDate 2018
dc.date.none.fl_str_mv 2018-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572018000100485
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572018000100485
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-7757-2017-0396
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
dc.source.none.fl_str_mv Journal of Applied Oral Science v.26 2018
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1748936439957028864