Relationship between friction force and orthodontic force at the leveling stage using a coated wire
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/80527 |
Resumo: | The relationship between orthodontic force and friction produced from an archwire and brackets affects the sliding of the wire in the leveling stage. Objective: The purpose of this study was to evaluate the relationship between force and friction in a small esthetic nickel-titanium (Ni-Ti) wire. Material and Methods: Five esthetic wires (three coated and two plated) and two small, plain Ni-Ti wires (0.012 and 0.014 inches) were used. We performed a three-point bending test according to ISO 15841 and the drawing test with a dental arch model designed with upper linguoversion of the lateral incisor in the arch (displacements of 0.5, 1.0, 2.0 and 3.0 mm), and evaluated the relationship between them. Results: Unloading bending forces of all wires at displacements of less than 1.0 mm were larger than friction forces, but all friction forces at displacements exceeding 2.0 mm were larger than unloading bending forces. The arch likely expands when displacement from the proximal brackets exceeds 1.0 mm. The friction force of a martensite 0.014-inch Ni-Ti wire was significantly greater than those of the other esthetic and austenitic wires. Conclusions: A wire with the smallest possible friction force should be used in cases with more than 1.0 mm displacement. |
id |
USP-17_51e38ca2c17d155479572d3501aed368 |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/80527 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire The relationship between orthodontic force and friction produced from an archwire and brackets affects the sliding of the wire in the leveling stage. Objective: The purpose of this study was to evaluate the relationship between force and friction in a small esthetic nickel-titanium (Ni-Ti) wire. Material and Methods: Five esthetic wires (three coated and two plated) and two small, plain Ni-Ti wires (0.012 and 0.014 inches) were used. We performed a three-point bending test according to ISO 15841 and the drawing test with a dental arch model designed with upper linguoversion of the lateral incisor in the arch (displacements of 0.5, 1.0, 2.0 and 3.0 mm), and evaluated the relationship between them. Results: Unloading bending forces of all wires at displacements of less than 1.0 mm were larger than friction forces, but all friction forces at displacements exceeding 2.0 mm were larger than unloading bending forces. The arch likely expands when displacement from the proximal brackets exceeds 1.0 mm. The friction force of a martensite 0.014-inch Ni-Ti wire was significantly greater than those of the other esthetic and austenitic wires. Conclusions: A wire with the smallest possible friction force should be used in cases with more than 1.0 mm displacement. Universidade de São Paulo. Faculdade de Odontologia de Bauru2013-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/8052710.1590/1679-775720130325Journal of Applied Oral Science; Vol. 21 No. 6 (2013); 554-559Journal of Applied Oral Science; Vol. 21 Núm. 6 (2013); 554-559Journal of Applied Oral Science; v. 21 n. 6 (2013); 554-5591678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/80527/84190Copyright (c) 2013 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessMURAYAMA, Masaki NAMURA, Yasuhiro TAMURA, Takahiko IWAI, Hiroaki SHIMIZU, Noriyoshi 2014-05-08T13:26:00Zoai:revistas.usp.br:article/80527Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2014-05-08T13:26Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire |
title |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire |
spellingShingle |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire MURAYAMA, Masaki |
title_short |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire |
title_full |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire |
title_fullStr |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire |
title_full_unstemmed |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire |
title_sort |
Relationship between friction force and orthodontic force at the leveling stage using a coated wire |
author |
MURAYAMA, Masaki |
author_facet |
MURAYAMA, Masaki NAMURA, Yasuhiro TAMURA, Takahiko IWAI, Hiroaki SHIMIZU, Noriyoshi |
author_role |
author |
author2 |
NAMURA, Yasuhiro TAMURA, Takahiko IWAI, Hiroaki SHIMIZU, Noriyoshi |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
MURAYAMA, Masaki NAMURA, Yasuhiro TAMURA, Takahiko IWAI, Hiroaki SHIMIZU, Noriyoshi |
description |
The relationship between orthodontic force and friction produced from an archwire and brackets affects the sliding of the wire in the leveling stage. Objective: The purpose of this study was to evaluate the relationship between force and friction in a small esthetic nickel-titanium (Ni-Ti) wire. Material and Methods: Five esthetic wires (three coated and two plated) and two small, plain Ni-Ti wires (0.012 and 0.014 inches) were used. We performed a three-point bending test according to ISO 15841 and the drawing test with a dental arch model designed with upper linguoversion of the lateral incisor in the arch (displacements of 0.5, 1.0, 2.0 and 3.0 mm), and evaluated the relationship between them. Results: Unloading bending forces of all wires at displacements of less than 1.0 mm were larger than friction forces, but all friction forces at displacements exceeding 2.0 mm were larger than unloading bending forces. The arch likely expands when displacement from the proximal brackets exceeds 1.0 mm. The friction force of a martensite 0.014-inch Ni-Ti wire was significantly greater than those of the other esthetic and austenitic wires. Conclusions: A wire with the smallest possible friction force should be used in cases with more than 1.0 mm displacement. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/80527 10.1590/1679-775720130325 |
url |
https://www.revistas.usp.br/jaos/article/view/80527 |
identifier_str_mv |
10.1590/1679-775720130325 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/80527/84190 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2013 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2013 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 21 No. 6 (2013); 554-559 Journal of Applied Oral Science; Vol. 21 Núm. 6 (2013); 554-559 Journal of Applied Oral Science; v. 21 n. 6 (2013); 554-559 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1800221678083506176 |