Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study

Detalhes bibliográficos
Autor(a) principal: MENDES, Bernardo de Azevedo Bahia
Data de Publicação: 2014
Outros Autores: FERREIRA, Ricardo Alberto Neto, PITHON, Matheus Melo, HORTA, Martinho Campolina Rebello, OLIVEIRA, Dauro Douglas
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/84002
Resumo: Objective: The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Material and Methods: Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. Results: The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. Conclusion: The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction.
id USP-17_5a7950923a5544de11911c71b7d2eee7
oai_identifier_str oai:revistas.usp.br:article/84002
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study Objective: The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Material and Methods: Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. Results: The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. Conclusion: The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction. Universidade de São Paulo. Faculdade de Odontologia de Bauru2014-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/8400210.1590/1678-775720130528Journal of Applied Oral Science; Vol. 22 No. 3 (2014); 194-203Journal of Applied Oral Science; Vol. 22 Núm. 3 (2014); 194-203Journal of Applied Oral Science; v. 22 n. 3 (2014); 194-2031678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/84002/86849Copyright (c) 2014 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessMENDES, Bernardo de Azevedo Bahia FERREIRA, Ricardo Alberto Neto PITHON, Matheus Melo HORTA, Martinho Campolina Rebello OLIVEIRA, Dauro Douglas 2014-08-26T23:50:42Zoai:revistas.usp.br:article/84002Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2014-08-26T23:50:42Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
title Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
spellingShingle Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
MENDES, Bernardo de Azevedo Bahia
title_short Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
title_full Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
title_fullStr Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
title_full_unstemmed Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
title_sort Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
author MENDES, Bernardo de Azevedo Bahia
author_facet MENDES, Bernardo de Azevedo Bahia
FERREIRA, Ricardo Alberto Neto
PITHON, Matheus Melo
HORTA, Martinho Campolina Rebello
OLIVEIRA, Dauro Douglas
author_role author
author2 FERREIRA, Ricardo Alberto Neto
PITHON, Matheus Melo
HORTA, Martinho Campolina Rebello
OLIVEIRA, Dauro Douglas
author2_role author
author
author
author
dc.contributor.author.fl_str_mv MENDES, Bernardo de Azevedo Bahia
FERREIRA, Ricardo Alberto Neto
PITHON, Matheus Melo
HORTA, Martinho Campolina Rebello
OLIVEIRA, Dauro Douglas
description Objective: The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Material and Methods: Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. Results: The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. Conclusion: The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction.
publishDate 2014
dc.date.none.fl_str_mv 2014-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/84002
10.1590/1678-775720130528
url https://www.revistas.usp.br/jaos/article/view/84002
identifier_str_mv 10.1590/1678-775720130528
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/84002/86849
dc.rights.driver.fl_str_mv Copyright (c) 2014 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2014 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 22 No. 3 (2014); 194-203
Journal of Applied Oral Science; Vol. 22 Núm. 3 (2014); 194-203
Journal of Applied Oral Science; v. 22 n. 3 (2014); 194-203
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221678145372160