Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses

Detalhes bibliográficos
Autor(a) principal: Fardin,Vinicius Pavesi
Data de Publicação: 2022
Outros Autores: Bonfante,Gerson, Coelho,Paulo G., Bergamo,Edmara T. P., Bordin,Dimorvan, Janal,Malvin N., Tovar,Nick, Witek,Lukasz, Bonfante,Estevam A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572022000100420
Resumo: Abstract Glass ceramics’ fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to failure-proneness. Objectives: To assess residual tensile stress using nanoindentation in veneered three-unit zirconia FDPs at different surfaces of pontics and abutments. Methodology: Three composite resin replicas of the maxillary first premolar and crown-prepared abutment first molar were made to obtain three-unit FDPs. The FDPs were veneered with glass ceramic containing fluorapatite crystals and resin cemented on the replicas, embedded in epoxy resin, sectioned, and polished. Each specimen was subjected to nanoindentation in the following regions of interest: 1) Mesial premolar abutment (MPMa); 2) Distal premolar abutment (DPMa); 3) Buccal premolar abutment (BPMa); 4) Lingual premolar abutment (LPMa); 5) Mesial premolar pontic (MPMp); 6) Distal premolar pontic (DPMp); 7) Buccal premolar pontic (BPMp); 8) Lingual premolar pontic (LPMp); 9) Mesial molar abutment (MMa); 10) Distal molar abutment (DMa); 11) Buccal molar abutment (BMa); and 12) Lingual molar abutment (LMa). Data were assessed using Linear Mixed Model and Least Significant Difference (95%) tests. Results: Pontics had significantly higher hardness values than premolar (p=0.001) and molar (p=0.007) abutments, suggesting lower residual stress levels. Marginal ridges yielded higher hardness values for connectors (DPMa, MMa, MPMp and DPMp) than for outer proximal surfaces of abutments (MPMa and DMa). The mesial marginal ridge of the premolar abutment (MPMa) had the lowest hardness values, suggesting higher residual stress concentration. Conclusions: Residual stress in three-unit FDPs was lower in pontics than in abutments. The outer proximal surfaces of the abutments had the highest residual stress concentration.
id USP-17_5e97541c9b786485debd1402121f5b0a
oai_identifier_str oai:scielo:S1678-77572022000100420
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prosthesesFatigueCeramicsFixed Partial DentureAbstract Glass ceramics’ fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to failure-proneness. Objectives: To assess residual tensile stress using nanoindentation in veneered three-unit zirconia FDPs at different surfaces of pontics and abutments. Methodology: Three composite resin replicas of the maxillary first premolar and crown-prepared abutment first molar were made to obtain three-unit FDPs. The FDPs were veneered with glass ceramic containing fluorapatite crystals and resin cemented on the replicas, embedded in epoxy resin, sectioned, and polished. Each specimen was subjected to nanoindentation in the following regions of interest: 1) Mesial premolar abutment (MPMa); 2) Distal premolar abutment (DPMa); 3) Buccal premolar abutment (BPMa); 4) Lingual premolar abutment (LPMa); 5) Mesial premolar pontic (MPMp); 6) Distal premolar pontic (DPMp); 7) Buccal premolar pontic (BPMp); 8) Lingual premolar pontic (LPMp); 9) Mesial molar abutment (MMa); 10) Distal molar abutment (DMa); 11) Buccal molar abutment (BMa); and 12) Lingual molar abutment (LMa). Data were assessed using Linear Mixed Model and Least Significant Difference (95%) tests. Results: Pontics had significantly higher hardness values than premolar (p=0.001) and molar (p=0.007) abutments, suggesting lower residual stress levels. Marginal ridges yielded higher hardness values for connectors (DPMa, MMa, MPMp and DPMp) than for outer proximal surfaces of abutments (MPMa and DMa). The mesial marginal ridge of the premolar abutment (MPMa) had the lowest hardness values, suggesting higher residual stress concentration. Conclusions: Residual stress in three-unit FDPs was lower in pontics than in abutments. The outer proximal surfaces of the abutments had the highest residual stress concentration.Faculdade De Odontologia De Bauru - USP2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572022000100420Journal of Applied Oral Science v.30 2022reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/1678-7757-2021-0475info:eu-repo/semantics/openAccessFardin,Vinicius PavesiBonfante,GersonCoelho,Paulo G.Bergamo,Edmara T. P.Bordin,DimorvanJanal,Malvin N.Tovar,NickWitek,LukaszBonfante,Estevam A.eng2022-04-18T00:00:00Zoai:scielo:S1678-77572022000100420Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2022-04-18T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses
title Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses
spellingShingle Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses
Fardin,Vinicius Pavesi
Fatigue
Ceramics
Fixed Partial Denture
title_short Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses
title_full Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses
title_fullStr Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses
title_full_unstemmed Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses
title_sort Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses
author Fardin,Vinicius Pavesi
author_facet Fardin,Vinicius Pavesi
Bonfante,Gerson
Coelho,Paulo G.
Bergamo,Edmara T. P.
Bordin,Dimorvan
Janal,Malvin N.
Tovar,Nick
Witek,Lukasz
Bonfante,Estevam A.
author_role author
author2 Bonfante,Gerson
Coelho,Paulo G.
Bergamo,Edmara T. P.
Bordin,Dimorvan
Janal,Malvin N.
Tovar,Nick
Witek,Lukasz
Bonfante,Estevam A.
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Fardin,Vinicius Pavesi
Bonfante,Gerson
Coelho,Paulo G.
Bergamo,Edmara T. P.
Bordin,Dimorvan
Janal,Malvin N.
Tovar,Nick
Witek,Lukasz
Bonfante,Estevam A.
dc.subject.por.fl_str_mv Fatigue
Ceramics
Fixed Partial Denture
topic Fatigue
Ceramics
Fixed Partial Denture
description Abstract Glass ceramics’ fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to failure-proneness. Objectives: To assess residual tensile stress using nanoindentation in veneered three-unit zirconia FDPs at different surfaces of pontics and abutments. Methodology: Three composite resin replicas of the maxillary first premolar and crown-prepared abutment first molar were made to obtain three-unit FDPs. The FDPs were veneered with glass ceramic containing fluorapatite crystals and resin cemented on the replicas, embedded in epoxy resin, sectioned, and polished. Each specimen was subjected to nanoindentation in the following regions of interest: 1) Mesial premolar abutment (MPMa); 2) Distal premolar abutment (DPMa); 3) Buccal premolar abutment (BPMa); 4) Lingual premolar abutment (LPMa); 5) Mesial premolar pontic (MPMp); 6) Distal premolar pontic (DPMp); 7) Buccal premolar pontic (BPMp); 8) Lingual premolar pontic (LPMp); 9) Mesial molar abutment (MMa); 10) Distal molar abutment (DMa); 11) Buccal molar abutment (BMa); and 12) Lingual molar abutment (LMa). Data were assessed using Linear Mixed Model and Least Significant Difference (95%) tests. Results: Pontics had significantly higher hardness values than premolar (p=0.001) and molar (p=0.007) abutments, suggesting lower residual stress levels. Marginal ridges yielded higher hardness values for connectors (DPMa, MMa, MPMp and DPMp) than for outer proximal surfaces of abutments (MPMa and DMa). The mesial marginal ridge of the premolar abutment (MPMa) had the lowest hardness values, suggesting higher residual stress concentration. Conclusions: Residual stress in three-unit FDPs was lower in pontics than in abutments. The outer proximal surfaces of the abutments had the highest residual stress concentration.
publishDate 2022
dc.date.none.fl_str_mv 2022-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572022000100420
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572022000100420
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-7757-2021-0475
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
dc.source.none.fl_str_mv Journal of Applied Oral Science v.30 2022
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1748936441213222912