Multiple-unit implant frames: one-piece casting vs. laser welding and brazing

Detalhes bibliográficos
Autor(a) principal: Costa, Elza Maria Valadares da
Data de Publicação: 2004
Outros Autores: Neisser, Maximiliano Piero, Bottino, Marco Antônio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3212
Resumo: The linear distortion of prostheses over implants, one-piece casting and cast in sections followed by laser welding by laser and brazing was evaluated in an edentulous mandibular model with five parallel abutments, with a distance of 10mm from center to center. Seventy five gold cylinders were tightened with screws on the abutments with 10Ncm torque. The cylinder/analogue assemblies were measured by microscopic examination (0.001mm accuracy) and the obtained results were compared with the GC (control group). Fifteen metal frames were waxed and cast in a gold alloy (Stabilor, Degussa Hulls, Brazil) and divided into three groups with five elements each, as followed: GM (one-piece casting), GB (section and brazing) and GL (section and laser welding). In all groups, measurements were taken at the right, left, buccal and lingual sides of the cylinder/analogue interface and the results were submitted to analysis of variance (ANOVA) and to the Tukey test (5%). The smallest amount of distortion was seen in the laser group (GL with a mean value of 13.58), followed by the brazing group (GB with a mean value of 24.33) and one-piece (GM with a mean value of 40.00). The greatest distortion was found in the one-piece group (GM).
id USP-17_6d3d6152b6aa0820c1f34c5f4c462857
oai_identifier_str oai:revistas.usp.br:article/3212
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Multiple-unit implant frames: one-piece casting vs. laser welding and brazing Sobre estruturas de implantes múltiplos: fundição em monobloco versus soldagem a laser e brasagem Implante sobre próteseImplante dentário endoósseoBrasagemImplant prosthesisEndosseous dental implantsWelding The linear distortion of prostheses over implants, one-piece casting and cast in sections followed by laser welding by laser and brazing was evaluated in an edentulous mandibular model with five parallel abutments, with a distance of 10mm from center to center. Seventy five gold cylinders were tightened with screws on the abutments with 10Ncm torque. The cylinder/analogue assemblies were measured by microscopic examination (0.001mm accuracy) and the obtained results were compared with the GC (control group). Fifteen metal frames were waxed and cast in a gold alloy (Stabilor, Degussa Hulls, Brazil) and divided into three groups with five elements each, as followed: GM (one-piece casting), GB (section and brazing) and GL (section and laser welding). In all groups, measurements were taken at the right, left, buccal and lingual sides of the cylinder/analogue interface and the results were submitted to analysis of variance (ANOVA) and to the Tukey test (5%). The smallest amount of distortion was seen in the laser group (GL with a mean value of 13.58), followed by the brazing group (GB with a mean value of 24.33) and one-piece (GM with a mean value of 40.00). The greatest distortion was found in the one-piece group (GM). A distorção linear das próteses sobre implantes, fundidas em monobloco e fundidas em secções e soldadas a laser e por brasagem foi avaliada em um modelo de uma mandíbula edêntula com cinco análogos de pilares de implantes, paralelos entre si com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco, GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observaram-se as estruturas fixadas com parafusos novos sob microscópio de mensuração. A medição foi realizada na vestibular direita e esquerda e da mesma forma na lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Média=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Média=23,06 e Dp=21,88) seguida pela técnica de monobloco (Média=39,83 e Dp=21,88) p=0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média=45,66 e Dp=21,56). Universidade de São Paulo. Faculdade de Odontologia de Bauru2004-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/321210.1590/S1678-77572004000300013Journal of Applied Oral Science; Vol. 12 No. 3 (2004); 227-231 Journal of Applied Oral Science; Vol. 12 Núm. 3 (2004); 227-231 Journal of Applied Oral Science; v. 12 n. 3 (2004); 227-231 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3212/3902Copyright (c) 2004 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessCosta, Elza Maria Valadares daNeisser, Maximiliano PieroBottino, Marco Antônio2012-04-27T11:48:10Zoai:revistas.usp.br:article/3212Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:48:10Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Multiple-unit implant frames: one-piece casting vs. laser welding and brazing
Sobre estruturas de implantes múltiplos: fundição em monobloco versus soldagem a laser e brasagem
title Multiple-unit implant frames: one-piece casting vs. laser welding and brazing
spellingShingle Multiple-unit implant frames: one-piece casting vs. laser welding and brazing
Costa, Elza Maria Valadares da
Implante sobre prótese
Implante dentário endoósseo
Brasagem
Implant prosthesis
Endosseous dental implants
Welding
title_short Multiple-unit implant frames: one-piece casting vs. laser welding and brazing
title_full Multiple-unit implant frames: one-piece casting vs. laser welding and brazing
title_fullStr Multiple-unit implant frames: one-piece casting vs. laser welding and brazing
title_full_unstemmed Multiple-unit implant frames: one-piece casting vs. laser welding and brazing
title_sort Multiple-unit implant frames: one-piece casting vs. laser welding and brazing
author Costa, Elza Maria Valadares da
author_facet Costa, Elza Maria Valadares da
Neisser, Maximiliano Piero
Bottino, Marco Antônio
author_role author
author2 Neisser, Maximiliano Piero
Bottino, Marco Antônio
author2_role author
author
dc.contributor.author.fl_str_mv Costa, Elza Maria Valadares da
Neisser, Maximiliano Piero
Bottino, Marco Antônio
dc.subject.por.fl_str_mv Implante sobre prótese
Implante dentário endoósseo
Brasagem
Implant prosthesis
Endosseous dental implants
Welding
topic Implante sobre prótese
Implante dentário endoósseo
Brasagem
Implant prosthesis
Endosseous dental implants
Welding
description The linear distortion of prostheses over implants, one-piece casting and cast in sections followed by laser welding by laser and brazing was evaluated in an edentulous mandibular model with five parallel abutments, with a distance of 10mm from center to center. Seventy five gold cylinders were tightened with screws on the abutments with 10Ncm torque. The cylinder/analogue assemblies were measured by microscopic examination (0.001mm accuracy) and the obtained results were compared with the GC (control group). Fifteen metal frames were waxed and cast in a gold alloy (Stabilor, Degussa Hulls, Brazil) and divided into three groups with five elements each, as followed: GM (one-piece casting), GB (section and brazing) and GL (section and laser welding). In all groups, measurements were taken at the right, left, buccal and lingual sides of the cylinder/analogue interface and the results were submitted to analysis of variance (ANOVA) and to the Tukey test (5%). The smallest amount of distortion was seen in the laser group (GL with a mean value of 13.58), followed by the brazing group (GB with a mean value of 24.33) and one-piece (GM with a mean value of 40.00). The greatest distortion was found in the one-piece group (GM).
publishDate 2004
dc.date.none.fl_str_mv 2004-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3212
10.1590/S1678-77572004000300013
url https://www.revistas.usp.br/jaos/article/view/3212
identifier_str_mv 10.1590/S1678-77572004000300013
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3212/3902
dc.rights.driver.fl_str_mv Copyright (c) 2004 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2004 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 12 No. 3 (2004); 227-231
Journal of Applied Oral Science; Vol. 12 Núm. 3 (2004); 227-231
Journal of Applied Oral Science; v. 12 n. 3 (2004); 227-231
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221671394639872