Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
DOI: | 10.1590/S1678-77572007000100005 |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/3426 |
Resumo: | STATEMENT OF PROBLEM: In clinical practice, loss of adhesion between the silicone-based denture liner and the denture base resin is always an undesirable event that might cause loss of material softness, water sorption, bacterial colonization and functional failure of the prosthesis. PURPOSE: This study evaluated the effect of thermocycling on tensile and shear bond strengths of three soft liner materials to a denture base acrylic resin. MATERIAL AND METHODS: Three resilient liners (Mucopren-Soft, Mollosil-Plus and Dentusil) and a heat-polymerized acrylic resin (QC-20) were processed according to manufacturers' directions. Sixty specimens (14 x 14 mm cross-sectional area) per bond strength test (20 for each liner) were fabricated and either stored in water at 37ºC for 24 hours (control groups; n=10) or thermocycled 3,000 times in water between 5ºC and 55ºC (test groups; n=10). The specimens were tested in tensile and shear strength in a universal testing machine until fracture. Bond strength means were compared between water-stored and thermocycled groups for each material, as well as among materials for each treatment (water storage or thermocycling). Failure mode (adhesive, cohesive and mixed) after debonding was assessed. Data were analyzed statistically by paired Student's t-test and ANOVA at 5% significance level. RESULTS: The water-stored groups had statistically significant higher bond strengths than the thermocycled groups (p |
id |
USP-17_79c3b5bf6ebc327ded119e9fd85b7b6a |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/3426 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
spelling |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin ThermocyclingSoft denture linersShear bond strengthTensile strengthDenture base resin STATEMENT OF PROBLEM: In clinical practice, loss of adhesion between the silicone-based denture liner and the denture base resin is always an undesirable event that might cause loss of material softness, water sorption, bacterial colonization and functional failure of the prosthesis. PURPOSE: This study evaluated the effect of thermocycling on tensile and shear bond strengths of three soft liner materials to a denture base acrylic resin. MATERIAL AND METHODS: Three resilient liners (Mucopren-Soft, Mollosil-Plus and Dentusil) and a heat-polymerized acrylic resin (QC-20) were processed according to manufacturers' directions. Sixty specimens (14 x 14 mm cross-sectional area) per bond strength test (20 for each liner) were fabricated and either stored in water at 37ºC for 24 hours (control groups; n=10) or thermocycled 3,000 times in water between 5ºC and 55ºC (test groups; n=10). The specimens were tested in tensile and shear strength in a universal testing machine until fracture. Bond strength means were compared between water-stored and thermocycled groups for each material, as well as among materials for each treatment (water storage or thermocycling). Failure mode (adhesive, cohesive and mixed) after debonding was assessed. Data were analyzed statistically by paired Student's t-test and ANOVA at 5% significance level. RESULTS: The water-stored groups had statistically significant higher bond strengths than the thermocycled groups (pUniversidade de São Paulo. Faculdade de Odontologia de Bauru2007-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/342610.1590/S1678-77572007000100005Journal of Applied Oral Science; Vol. 15 No. 1 (2007); 18-23 Journal of Applied Oral Science; Vol. 15 Núm. 1 (2007); 18-23 Journal of Applied Oral Science; v. 15 n. 1 (2007); 18-23 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3426/4116Copyright (c) 2007 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessElias, Carlos NelsonHenriques, Flavio Queiroz2012-04-27T11:56:08Zoai:revistas.usp.br:article/3426Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:56:08Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin |
title |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin |
spellingShingle |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin Elias, Carlos Nelson Thermocycling Soft denture liners Shear bond strength Tensile strength Denture base resin Elias, Carlos Nelson Thermocycling Soft denture liners Shear bond strength Tensile strength Denture base resin |
title_short |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin |
title_full |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin |
title_fullStr |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin |
title_full_unstemmed |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin |
title_sort |
Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin |
author |
Elias, Carlos Nelson |
author_facet |
Elias, Carlos Nelson Elias, Carlos Nelson Henriques, Flavio Queiroz Henriques, Flavio Queiroz |
author_role |
author |
author2 |
Henriques, Flavio Queiroz |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Elias, Carlos Nelson Henriques, Flavio Queiroz |
dc.subject.por.fl_str_mv |
Thermocycling Soft denture liners Shear bond strength Tensile strength Denture base resin |
topic |
Thermocycling Soft denture liners Shear bond strength Tensile strength Denture base resin |
description |
STATEMENT OF PROBLEM: In clinical practice, loss of adhesion between the silicone-based denture liner and the denture base resin is always an undesirable event that might cause loss of material softness, water sorption, bacterial colonization and functional failure of the prosthesis. PURPOSE: This study evaluated the effect of thermocycling on tensile and shear bond strengths of three soft liner materials to a denture base acrylic resin. MATERIAL AND METHODS: Three resilient liners (Mucopren-Soft, Mollosil-Plus and Dentusil) and a heat-polymerized acrylic resin (QC-20) were processed according to manufacturers' directions. Sixty specimens (14 x 14 mm cross-sectional area) per bond strength test (20 for each liner) were fabricated and either stored in water at 37ºC for 24 hours (control groups; n=10) or thermocycled 3,000 times in water between 5ºC and 55ºC (test groups; n=10). The specimens were tested in tensile and shear strength in a universal testing machine until fracture. Bond strength means were compared between water-stored and thermocycled groups for each material, as well as among materials for each treatment (water storage or thermocycling). Failure mode (adhesive, cohesive and mixed) after debonding was assessed. Data were analyzed statistically by paired Student's t-test and ANOVA at 5% significance level. RESULTS: The water-stored groups had statistically significant higher bond strengths than the thermocycled groups (p |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3426 10.1590/S1678-77572007000100005 |
url |
https://www.revistas.usp.br/jaos/article/view/3426 |
identifier_str_mv |
10.1590/S1678-77572007000100005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3426/4116 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2007 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2007 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 15 No. 1 (2007); 18-23 Journal of Applied Oral Science; Vol. 15 Núm. 1 (2007); 18-23 Journal of Applied Oral Science; v. 15 n. 1 (2007); 18-23 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1822179109869977600 |
dc.identifier.doi.none.fl_str_mv |
10.1590/S1678-77572007000100005 |