The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/125356 |
Resumo: | Objective Fine-needle aspiration cytology is a valuable method for preoperative assessment of head and neck tumors. However, its accuracy in detection of salivary gland masses is controversial compared with other methods. The aim of this work was to evaluate the effectiveness and accuracy of fine-needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses. Material and Methods Over a 10-year period, 126 parotid gland masses were resected. Retrospective chart reviews of 114 patients were performed. The results of FNAC and final histological diagnosis were compared and the accuracy of FNAC was determined. Results Final histological evaluation revealed 11 malignant tumors and 103 benign lesions. Pleomorphic adenoma was the most common neoplasm (63%), followed by Warthin’s tumor (17.5%). The sensitivity of FNAC in detecting malignant tumors was 73% and the specificity was 97%. Positive predictive value (PPV) was 73% and negative predictive value (NPV) was 97%. The overall accuracy of FNAC in detecting parotid masses was 95%. False-negative diagnosis was found in mucoepidermoid carcinoma, acinic cell carcinoma, and epithelial-myoepithelial carcinoma whereas there was false-positive diagnosis in cases of pleomorphic adenoma and normal parotid gland tissue. Conclusion FNAC is a reliable minimally invasive diagnostic method with a high sensitivity in diagnosis of lesions in parotid glands. The sensitivity of detection of malignant tumors in parotid glands was low due to the biopsy technique used, and depended on tumor location. Postoperative complications decreased after superficial parotidectomy. |
id |
USP-17_83f1acbc82600b733786f727f6a6f2a6 |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/125356 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients Objective Fine-needle aspiration cytology is a valuable method for preoperative assessment of head and neck tumors. However, its accuracy in detection of salivary gland masses is controversial compared with other methods. The aim of this work was to evaluate the effectiveness and accuracy of fine-needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses. Material and Methods Over a 10-year period, 126 parotid gland masses were resected. Retrospective chart reviews of 114 patients were performed. The results of FNAC and final histological diagnosis were compared and the accuracy of FNAC was determined. Results Final histological evaluation revealed 11 malignant tumors and 103 benign lesions. Pleomorphic adenoma was the most common neoplasm (63%), followed by Warthin’s tumor (17.5%). The sensitivity of FNAC in detecting malignant tumors was 73% and the specificity was 97%. Positive predictive value (PPV) was 73% and negative predictive value (NPV) was 97%. The overall accuracy of FNAC in detecting parotid masses was 95%. False-negative diagnosis was found in mucoepidermoid carcinoma, acinic cell carcinoma, and epithelial-myoepithelial carcinoma whereas there was false-positive diagnosis in cases of pleomorphic adenoma and normal parotid gland tissue. Conclusion FNAC is a reliable minimally invasive diagnostic method with a high sensitivity in diagnosis of lesions in parotid glands. The sensitivity of detection of malignant tumors in parotid glands was low due to the biopsy technique used, and depended on tumor location. Postoperative complications decreased after superficial parotidectomy. Universidade de São Paulo. Faculdade de Odontologia de Bauru2016-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/12535610.1590/1678-775720160214Journal of Applied Oral Science; Vol. 24 No. 6 (2016); 561-567Journal of Applied Oral Science; Vol. 24 Núm. 6 (2016); 561-567Journal of Applied Oral Science; v. 24 n. 6 (2016); 561-5671678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/125356/122379Copyright (c) 2016 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessGUDMUNDSSON, Jens KristjanAJAN, AidaABTAHI, Jahan2017-01-05T19:02:03Zoai:revistas.usp.br:article/125356Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2017-01-05T19:02:03Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients |
title |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients |
spellingShingle |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients GUDMUNDSSON, Jens Kristjan |
title_short |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients |
title_full |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients |
title_fullStr |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients |
title_full_unstemmed |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients |
title_sort |
The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients |
author |
GUDMUNDSSON, Jens Kristjan |
author_facet |
GUDMUNDSSON, Jens Kristjan AJAN, Aida ABTAHI, Jahan |
author_role |
author |
author2 |
AJAN, Aida ABTAHI, Jahan |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
GUDMUNDSSON, Jens Kristjan AJAN, Aida ABTAHI, Jahan |
description |
Objective Fine-needle aspiration cytology is a valuable method for preoperative assessment of head and neck tumors. However, its accuracy in detection of salivary gland masses is controversial compared with other methods. The aim of this work was to evaluate the effectiveness and accuracy of fine-needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses. Material and Methods Over a 10-year period, 126 parotid gland masses were resected. Retrospective chart reviews of 114 patients were performed. The results of FNAC and final histological diagnosis were compared and the accuracy of FNAC was determined. Results Final histological evaluation revealed 11 malignant tumors and 103 benign lesions. Pleomorphic adenoma was the most common neoplasm (63%), followed by Warthin’s tumor (17.5%). The sensitivity of FNAC in detecting malignant tumors was 73% and the specificity was 97%. Positive predictive value (PPV) was 73% and negative predictive value (NPV) was 97%. The overall accuracy of FNAC in detecting parotid masses was 95%. False-negative diagnosis was found in mucoepidermoid carcinoma, acinic cell carcinoma, and epithelial-myoepithelial carcinoma whereas there was false-positive diagnosis in cases of pleomorphic adenoma and normal parotid gland tissue. Conclusion FNAC is a reliable minimally invasive diagnostic method with a high sensitivity in diagnosis of lesions in parotid glands. The sensitivity of detection of malignant tumors in parotid glands was low due to the biopsy technique used, and depended on tumor location. Postoperative complications decreased after superficial parotidectomy. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/125356 10.1590/1678-775720160214 |
url |
https://www.revistas.usp.br/jaos/article/view/125356 |
identifier_str_mv |
10.1590/1678-775720160214 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/125356/122379 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2016 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2016 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 24 No. 6 (2016); 561-567 Journal of Applied Oral Science; Vol. 24 Núm. 6 (2016); 561-567 Journal of Applied Oral Science; v. 24 n. 6 (2016); 561-567 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1800221679708798976 |