Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study

Detalhes bibliográficos
Autor(a) principal: Queiroz,Polyane Mazucatto
Data de Publicação: 2017
Outros Autores: Rovaris,Karla, Santaella,Gustavo Machado, Haiter-Neto,Francisco, Freitas,Deborah Queiroz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572017000600674
Resumo: Abstract To calculate root canal volume and surface area in microCT images, an image segmentation by selecting threshold values is required, which can be determined by visual or automatic methods. Visual determination is influenced by the operator's visual acuity, while the automatic method is done entirely by computer algorithms. Objective: To compare between visual and automatic segmentation, and to determine the influence of the operator's visual acuity on the reproducibility of root canal volume and area measurements. Material and methods: Images from 31 extracted human anterior teeth were scanned with a μCT scanner. Three experienced examiners performed visual image segmentation, and threshold values were recorded. Automatic segmentation was done using the “Automatic Threshold Tool” available in the dedicated software provided by the scanner's manufacturer. Volume and area measurements were performed using the threshold values determined both visually and automatically. Results: The paired Student's t-test showed no significant difference between visual and automatic segmentation methods regarding root canal volume measurements (p=0.93) and root canal surface (p=0.79). Conclusion: Although visual and automatic segmentation methods can be used to determine the threshold and calculate root canal volume and surface, the automatic method may be the most suitable for ensuring the reproducibility of threshold determination.
id USP-17_b16429c45872a418d32136959c08d641
oai_identifier_str oai:scielo:S1678-77572017000600674
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT studyDental pulp cavityThreshold limit valuesX-ray microtomographyAbstract To calculate root canal volume and surface area in microCT images, an image segmentation by selecting threshold values is required, which can be determined by visual or automatic methods. Visual determination is influenced by the operator's visual acuity, while the automatic method is done entirely by computer algorithms. Objective: To compare between visual and automatic segmentation, and to determine the influence of the operator's visual acuity on the reproducibility of root canal volume and area measurements. Material and methods: Images from 31 extracted human anterior teeth were scanned with a μCT scanner. Three experienced examiners performed visual image segmentation, and threshold values were recorded. Automatic segmentation was done using the “Automatic Threshold Tool” available in the dedicated software provided by the scanner's manufacturer. Volume and area measurements were performed using the threshold values determined both visually and automatically. Results: The paired Student's t-test showed no significant difference between visual and automatic segmentation methods regarding root canal volume measurements (p=0.93) and root canal surface (p=0.79). Conclusion: Although visual and automatic segmentation methods can be used to determine the threshold and calculate root canal volume and surface, the automatic method may be the most suitable for ensuring the reproducibility of threshold determination.Faculdade De Odontologia De Bauru - USP2017-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572017000600674Journal of Applied Oral Science v.25 n.6 2017reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/1678-7757-2017-0023info:eu-repo/semantics/openAccessQueiroz,Polyane MazucattoRovaris,KarlaSantaella,Gustavo MachadoHaiter-Neto,FranciscoFreitas,Deborah Queirozeng2017-11-27T00:00:00Zoai:scielo:S1678-77572017000600674Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2017-11-27T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
title Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
spellingShingle Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
Queiroz,Polyane Mazucatto
Dental pulp cavity
Threshold limit values
X-ray microtomography
title_short Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
title_full Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
title_fullStr Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
title_full_unstemmed Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
title_sort Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study
author Queiroz,Polyane Mazucatto
author_facet Queiroz,Polyane Mazucatto
Rovaris,Karla
Santaella,Gustavo Machado
Haiter-Neto,Francisco
Freitas,Deborah Queiroz
author_role author
author2 Rovaris,Karla
Santaella,Gustavo Machado
Haiter-Neto,Francisco
Freitas,Deborah Queiroz
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Queiroz,Polyane Mazucatto
Rovaris,Karla
Santaella,Gustavo Machado
Haiter-Neto,Francisco
Freitas,Deborah Queiroz
dc.subject.por.fl_str_mv Dental pulp cavity
Threshold limit values
X-ray microtomography
topic Dental pulp cavity
Threshold limit values
X-ray microtomography
description Abstract To calculate root canal volume and surface area in microCT images, an image segmentation by selecting threshold values is required, which can be determined by visual or automatic methods. Visual determination is influenced by the operator's visual acuity, while the automatic method is done entirely by computer algorithms. Objective: To compare between visual and automatic segmentation, and to determine the influence of the operator's visual acuity on the reproducibility of root canal volume and area measurements. Material and methods: Images from 31 extracted human anterior teeth were scanned with a μCT scanner. Three experienced examiners performed visual image segmentation, and threshold values were recorded. Automatic segmentation was done using the “Automatic Threshold Tool” available in the dedicated software provided by the scanner's manufacturer. Volume and area measurements were performed using the threshold values determined both visually and automatically. Results: The paired Student's t-test showed no significant difference between visual and automatic segmentation methods regarding root canal volume measurements (p=0.93) and root canal surface (p=0.79). Conclusion: Although visual and automatic segmentation methods can be used to determine the threshold and calculate root canal volume and surface, the automatic method may be the most suitable for ensuring the reproducibility of threshold determination.
publishDate 2017
dc.date.none.fl_str_mv 2017-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572017000600674
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572017000600674
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-7757-2017-0023
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
dc.source.none.fl_str_mv Journal of Applied Oral Science v.25 n.6 2017
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1748936439505092608