Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis

Detalhes bibliográficos
Autor(a) principal: Vasconcellos, Luis Gustavo Oliveira de
Data de Publicação: 2011
Outros Autores: Nishioka, Renato Sussumu, Vasconcellos, Luana Marotta Reis de, Nishioka, Lea Nogueira Braulino de Melo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3962
Resumo: OBJECTIVES: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. MATERIAL AND METHODS: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p
id USP-17_d1230f32147b41df8d1ace59bd672d5e
oai_identifier_str oai:revistas.usp.br:article/3962
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis BiomechanicsDental implantsDental prosthesisImplant-supported dental prosthesis OBJECTIVES: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. MATERIAL AND METHODS: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of pUniversidade de São Paulo. Faculdade de Odontologia de Bauru2011-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/396210.1590/S1678-77572011000600011Journal of Applied Oral Science; Vol. 19 No. 6 (2011); 610-615 Journal of Applied Oral Science; Vol. 19 Núm. 6 (2011); 610-615 Journal of Applied Oral Science; v. 19 n. 6 (2011); 610-615 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3962/4652Copyright (c) 2011 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessVasconcellos, Luis Gustavo Oliveira deNishioka, Renato SussumuVasconcellos, Luana Marotta Reis deNishioka, Lea Nogueira Braulino de Melo2012-04-27T12:16:27Zoai:revistas.usp.br:article/3962Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T12:16:27Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
title Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
spellingShingle Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
Vasconcellos, Luis Gustavo Oliveira de
Biomechanics
Dental implants
Dental prosthesis
Implant-supported dental prosthesis
title_short Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
title_full Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
title_fullStr Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
title_full_unstemmed Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
title_sort Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
author Vasconcellos, Luis Gustavo Oliveira de
author_facet Vasconcellos, Luis Gustavo Oliveira de
Nishioka, Renato Sussumu
Vasconcellos, Luana Marotta Reis de
Nishioka, Lea Nogueira Braulino de Melo
author_role author
author2 Nishioka, Renato Sussumu
Vasconcellos, Luana Marotta Reis de
Nishioka, Lea Nogueira Braulino de Melo
author2_role author
author
author
dc.contributor.author.fl_str_mv Vasconcellos, Luis Gustavo Oliveira de
Nishioka, Renato Sussumu
Vasconcellos, Luana Marotta Reis de
Nishioka, Lea Nogueira Braulino de Melo
dc.subject.por.fl_str_mv Biomechanics
Dental implants
Dental prosthesis
Implant-supported dental prosthesis
topic Biomechanics
Dental implants
Dental prosthesis
Implant-supported dental prosthesis
description OBJECTIVES: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. MATERIAL AND METHODS: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p
publishDate 2011
dc.date.none.fl_str_mv 2011-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3962
10.1590/S1678-77572011000600011
url https://www.revistas.usp.br/jaos/article/view/3962
identifier_str_mv 10.1590/S1678-77572011000600011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3962/4652
dc.rights.driver.fl_str_mv Copyright (c) 2011 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2011 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 19 No. 6 (2011); 610-615
Journal of Applied Oral Science; Vol. 19 Núm. 6 (2011); 610-615
Journal of Applied Oral Science; v. 19 n. 6 (2011); 610-615
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221676888129536