Microhardness evaluation around composite restorations using fluoride-containing adhesive systems

Detalhes bibliográficos
Autor(a) principal: Magalhães, Cláudia Silami de
Data de Publicação: 2005
Outros Autores: Hara, Anderson Takeo, Turssi, Cecilia Pedroso, Serra, Mônica Campos, Giannini, Marcelo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3289
Resumo: The purpose of this study was to evaluate the microhardness of dental enamel around composite restorations bonded with fluoride-containing adhesive systems (FCAS), after thermo- and pH-cycling protocols. Standardized cylindrical cavities were prepared on enamel surfaces of 175 dental fragments, which were randomly assigned into seven experimental groups (n=25). Four groups used FCAS: Optibond Solo (OS); Prime&Bond 2.1 (PB); Syntac Sprint (SS) and Tenure Quick (TC). Other groups consisted of "Sandwich" technique restoration (STR) (glass ionomer liner + hydrophobic adhesive resin /restorative composite) or used Single Bond with (SB) or without (SBWC) cycling protocols. Adhesive systems were applied according to manufacturers' instructions and cavities were restored with a microfilled composite (Durafill VS). After finishing and polishing, all groups were submitted to 1,000 thermal cycles (5 ºC and 55 ºC) and to demineralization (pH 4.3) and remineralization (pH 7.0) cycling protocols, except for SBWC group. The Knoop microhardness of enamel surfaces were measured around restorations. Indentations were recorded at 150, 300 and 450-mm from the cavity wall. Data were analyzed by two-way ANOVA and Duncan's Test (a=0.05%). Means ± SD of enamel microhardness for the groups were (Kg/mm²): SBWC: 314.50 ± 55.93ª ; SB: 256.78 ± 62.66b; STR: 253.90 ± 83.6b; TQ: 243.93 ± 68.3b; OS: 227.97 ± 67.1c; PB: 213.30 ± 91.3d; SS: 208.73 ± 86.6d. Means ± SD of microhardness for the distances 150, 300, 450mm from the cavity wall were, respectively: 234.46 ± 77.81ª; 240.24 ± 85.12ª; 262.06 ± 79.46b. SBWC group, which was not submitted to thermo- and pH-cycling protocols, showed the highest enamel microhardness mean value and the FCAS resulted in lower microhardness values. At 450 mm from the cavity wall, the enamel microhardness increased significantly.
id USP-17_d88e0638da1f1f1e614cb415f8ae0745
oai_identifier_str oai:revistas.usp.br:article/3289
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Microhardness evaluation around composite restorations using fluoride-containing adhesive systems Avaliação da microdureza ao redor de restaurações de compósito confeccionadas com sistemas adesivos contendo fluoretos Esmalte dentárioFluoretoSistemas adesivosMicrodurezaDental enamelFluorideAdhesive systemsMicrohardness The purpose of this study was to evaluate the microhardness of dental enamel around composite restorations bonded with fluoride-containing adhesive systems (FCAS), after thermo- and pH-cycling protocols. Standardized cylindrical cavities were prepared on enamel surfaces of 175 dental fragments, which were randomly assigned into seven experimental groups (n=25). Four groups used FCAS: Optibond Solo (OS); Prime&Bond 2.1 (PB); Syntac Sprint (SS) and Tenure Quick (TC). Other groups consisted of "Sandwich" technique restoration (STR) (glass ionomer liner + hydrophobic adhesive resin /restorative composite) or used Single Bond with (SB) or without (SBWC) cycling protocols. Adhesive systems were applied according to manufacturers' instructions and cavities were restored with a microfilled composite (Durafill VS). After finishing and polishing, all groups were submitted to 1,000 thermal cycles (5 ºC and 55 ºC) and to demineralization (pH 4.3) and remineralization (pH 7.0) cycling protocols, except for SBWC group. The Knoop microhardness of enamel surfaces were measured around restorations. Indentations were recorded at 150, 300 and 450-mm from the cavity wall. Data were analyzed by two-way ANOVA and Duncan's Test (a=0.05%). Means ± SD of enamel microhardness for the groups were (Kg/mm²): SBWC: 314.50 ± 55.93ª ; SB: 256.78 ± 62.66b; STR: 253.90 ± 83.6b; TQ: 243.93 ± 68.3b; OS: 227.97 ± 67.1c; PB: 213.30 ± 91.3d; SS: 208.73 ± 86.6d. Means ± SD of microhardness for the distances 150, 300, 450mm from the cavity wall were, respectively: 234.46 ± 77.81ª; 240.24 ± 85.12ª; 262.06 ± 79.46b. SBWC group, which was not submitted to thermo- and pH-cycling protocols, showed the highest enamel microhardness mean value and the FCAS resulted in lower microhardness values. At 450 mm from the cavity wall, the enamel microhardness increased significantly. O objetivo deste estudo foi avaliar a microdureza do esmalte dental ao redor de restaurações em compósito que utilizaram sistemas adesivos contendo fluoretos (FCAS), após tratamento dessas superfícies restauradas aos protocolos de ciclagem térmica e pH. Cavidades cilíndricas padronizadas foram preparadas em 175 superfícies de esmalte de fragmentos dentais, os quais foram aleatoriamente divididos em sete grupos (n=25). Quatro grupos utilizaram os FCAS: Optibond Solo (OS); Prime&Bond 2.1 (PB); Syntac Sprint (SS) e Tenure Quick (TC). Outros grupos consistiram em restaurações "Sandwich" (STR - ionômero de vidro como base + restauração em composíto) ou utilizaram Single Bond com (SB) ou sem (SBWC) ciclagens. Os sistemas adesivos foram aplicados segundo as instruções dos fabricantes e as cavidades restauradas com compósito microparticulado (Durafill VS). Após o acabamento e polimento, todos grupos foram submetidos a 1.000 ciclos térmicos (5 ºC e 55 ºC) e a um protocolo de ciclagem de pH (desmineralização-pH 4,3 e remineralização-pH 7,0), exceto para o grupo SBWC. A microdureza das superfícies de esmalte foi mensurada ao redor das restaurações. Indentações foram feitas nas distâncias de 100, 300 and 450-mm da parede cavitária. Os dados foram analisados pela ANOVA (2 fatores) and Teste de Duncan (5%). Os valores médios ± DP da microdureza do esmalte para os grupos foram (Kg/mm²): SBWC: 314,50 ± 55,93ª ; SB: 256,78 ± 62,66b; STR: 253,90 ± 83,6b; TQ: 243,93 ± 68,3b; OS: 227,97 ± 67,1c; PB: 213,30 ± 91,3d; SS: 208,73 ± 86,6d. As médias ± DP de microdureza para as distâncias 150, 300, 450 mm da parede cavitária foram, respectivamente: 234,46 ± 77,81ª; 240,24 ± 85,12ª; 262,06 ± 79,46b. O grupo SBWC que não foi submetido aos protocolos de ciclagem térmica e pH mostrou a maior média de microdureza do esmalte e os FCAS resultaram nos menores valores de microdureza. Na distância de 450 mm da parede cavitária, a microdureza apresentou aumento significativo. Universidade de São Paulo. Faculdade de Odontologia de Bauru2005-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/328910.1590/S1678-77572005000300011Journal of Applied Oral Science; Vol. 13 No. 3 (2005); 259-264 Journal of Applied Oral Science; Vol. 13 Núm. 3 (2005); 259-264 Journal of Applied Oral Science; v. 13 n. 3 (2005); 259-264 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3289/3979Copyright (c) 2005 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessMagalhães, Cláudia Silami deHara, Anderson TakeoTurssi, Cecilia PedrosoSerra, Mônica CamposGiannini, Marcelo2012-04-27T11:51:02Zoai:revistas.usp.br:article/3289Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:51:02Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Microhardness evaluation around composite restorations using fluoride-containing adhesive systems
Avaliação da microdureza ao redor de restaurações de compósito confeccionadas com sistemas adesivos contendo fluoretos
title Microhardness evaluation around composite restorations using fluoride-containing adhesive systems
spellingShingle Microhardness evaluation around composite restorations using fluoride-containing adhesive systems
Magalhães, Cláudia Silami de
Esmalte dentário
Fluoreto
Sistemas adesivos
Microdureza
Dental enamel
Fluoride
Adhesive systems
Microhardness
title_short Microhardness evaluation around composite restorations using fluoride-containing adhesive systems
title_full Microhardness evaluation around composite restorations using fluoride-containing adhesive systems
title_fullStr Microhardness evaluation around composite restorations using fluoride-containing adhesive systems
title_full_unstemmed Microhardness evaluation around composite restorations using fluoride-containing adhesive systems
title_sort Microhardness evaluation around composite restorations using fluoride-containing adhesive systems
author Magalhães, Cláudia Silami de
author_facet Magalhães, Cláudia Silami de
Hara, Anderson Takeo
Turssi, Cecilia Pedroso
Serra, Mônica Campos
Giannini, Marcelo
author_role author
author2 Hara, Anderson Takeo
Turssi, Cecilia Pedroso
Serra, Mônica Campos
Giannini, Marcelo
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Magalhães, Cláudia Silami de
Hara, Anderson Takeo
Turssi, Cecilia Pedroso
Serra, Mônica Campos
Giannini, Marcelo
dc.subject.por.fl_str_mv Esmalte dentário
Fluoreto
Sistemas adesivos
Microdureza
Dental enamel
Fluoride
Adhesive systems
Microhardness
topic Esmalte dentário
Fluoreto
Sistemas adesivos
Microdureza
Dental enamel
Fluoride
Adhesive systems
Microhardness
description The purpose of this study was to evaluate the microhardness of dental enamel around composite restorations bonded with fluoride-containing adhesive systems (FCAS), after thermo- and pH-cycling protocols. Standardized cylindrical cavities were prepared on enamel surfaces of 175 dental fragments, which were randomly assigned into seven experimental groups (n=25). Four groups used FCAS: Optibond Solo (OS); Prime&Bond 2.1 (PB); Syntac Sprint (SS) and Tenure Quick (TC). Other groups consisted of "Sandwich" technique restoration (STR) (glass ionomer liner + hydrophobic adhesive resin /restorative composite) or used Single Bond with (SB) or without (SBWC) cycling protocols. Adhesive systems were applied according to manufacturers' instructions and cavities were restored with a microfilled composite (Durafill VS). After finishing and polishing, all groups were submitted to 1,000 thermal cycles (5 ºC and 55 ºC) and to demineralization (pH 4.3) and remineralization (pH 7.0) cycling protocols, except for SBWC group. The Knoop microhardness of enamel surfaces were measured around restorations. Indentations were recorded at 150, 300 and 450-mm from the cavity wall. Data were analyzed by two-way ANOVA and Duncan's Test (a=0.05%). Means ± SD of enamel microhardness for the groups were (Kg/mm²): SBWC: 314.50 ± 55.93ª ; SB: 256.78 ± 62.66b; STR: 253.90 ± 83.6b; TQ: 243.93 ± 68.3b; OS: 227.97 ± 67.1c; PB: 213.30 ± 91.3d; SS: 208.73 ± 86.6d. Means ± SD of microhardness for the distances 150, 300, 450mm from the cavity wall were, respectively: 234.46 ± 77.81ª; 240.24 ± 85.12ª; 262.06 ± 79.46b. SBWC group, which was not submitted to thermo- and pH-cycling protocols, showed the highest enamel microhardness mean value and the FCAS resulted in lower microhardness values. At 450 mm from the cavity wall, the enamel microhardness increased significantly.
publishDate 2005
dc.date.none.fl_str_mv 2005-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3289
10.1590/S1678-77572005000300011
url https://www.revistas.usp.br/jaos/article/view/3289
identifier_str_mv 10.1590/S1678-77572005000300011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3289/3979
dc.rights.driver.fl_str_mv Copyright (c) 2005 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2005 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 13 No. 3 (2005); 259-264
Journal of Applied Oral Science; Vol. 13 Núm. 3 (2005); 259-264
Journal of Applied Oral Science; v. 13 n. 3 (2005); 259-264
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221672085651456