One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/3135 |
Resumo: | The purpose of this study was to assess the clinical performance of bonded composite (Excite/Tetric Ceram - Vivadent) versus a resin-modified glass ionomer cement (Vitremer - 3M) for restoring non-carious cervical lesions. A total of 70 restorations (thirty-five per material) were placed in 30 patients, 18-50 aged, by one operator. Rubber dam was employed in all cases, lesions were pumiced, enamel margins were not beveled, and no mechanical retention was placed. The restorations were directly assessed by two independent evaluators using modified-USPHS criteria for six clinical categories. The ratings for clinical acceptability restorations (alfa plus bravo) were as follows (Tetric Ceram/Vitremer): retention (86%/100%), marginal integrity (100%/100%), marginal discoloration (100%/100%), wear (97%/100%), postoperative sensitivity (100%/100%) and recurrent caries (100%/100%). Statistical analysis was completed with Fisher's exact or Pearson Chi-square tests at a significance level of 5% (P |
id |
USP-17_ddb6648165e72c4c24ae9b7b1df48c4a |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/3135 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions Avaliação clínica de restaurações de lesões cervicais não cariosas Lesão cervicalResinas compostasCimentos de ionômero de vidroCervical lesionComposite resinsGlass ionomer cements The purpose of this study was to assess the clinical performance of bonded composite (Excite/Tetric Ceram - Vivadent) versus a resin-modified glass ionomer cement (Vitremer - 3M) for restoring non-carious cervical lesions. A total of 70 restorations (thirty-five per material) were placed in 30 patients, 18-50 aged, by one operator. Rubber dam was employed in all cases, lesions were pumiced, enamel margins were not beveled, and no mechanical retention was placed. The restorations were directly assessed by two independent evaluators using modified-USPHS criteria for six clinical categories. The ratings for clinical acceptability restorations (alfa plus bravo) were as follows (Tetric Ceram/Vitremer): retention (86%/100%), marginal integrity (100%/100%), marginal discoloration (100%/100%), wear (97%/100%), postoperative sensitivity (100%/100%) and recurrent caries (100%/100%). Statistical analysis was completed with Fisher's exact or Pearson Chi-square tests at a significance level of 5% (P Avaliou-se o desempenho clínico de um sistema restaurador adesivo (Excite - Tetric Ceram/ Vivadent) e do cimento de ionômero de vidro modificado por resina (Vitremer/ 3M) na restauração de lesões cervicais não cariosas por meio do sistema de avaliação do USPHS modificado. Um total de setenta restaurações, trinta e cinco por material, foi realizado por um único operador em trinta pacientes voluntários com idades de 18 a 50 anos. Previamente à execução das restaurações, foi realizada uma profilaxia com pedra-pomes e água a fim de remover quaisquer resíduos. As lesões cervicais não foram submetidas a qualquer tipo de preparo cavitário, sendo restauradas sob isolamento absoluto e de acordo com as instruções do fabricante. Todas as restaurações foram avaliadas pelo método direto por dois examinadores usando os critérios de retenção (R), integridade marginal (IM), descoloração marginal (DM), desgaste (D), sensibilidade pós-operatória (S) e incidência de cárie (IC). Ao final de um ano, os resultados de restaurações clinicamente satisfatórios (escores Alfa e Bravo) obtidos para resina composta e cimento de ionômerto de vidro modificado por resina foram respectivamente: R (86%/100%), IM (100%/100%), DM (100%/100%), D (97%/100%), S (100%/100%) e IC (100%/100%). Os resultados foram submetidos à análise estatística com o teste exato de Fisher ou o teste Qui-quadrado de Pearson com o nível de significância de 5% (pUniversidade de São Paulo. Faculdade de Odontologia de Bauru2003-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/313510.1590/S1678-77572003000300004Journal of Applied Oral Science; Vol. 11 No. 3 (2003); 175-180 Journal of Applied Oral Science; Vol. 11 Núm. 3 (2003); 175-180 Journal of Applied Oral Science; v. 11 n. 3 (2003); 175-180 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3135/3824Copyright (c) 2003 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessSantiago, Sérgio LimaFranco, Eduardo BatistaMendonça, Juliano SartoriLauris, José Roberto PereiraNavarro, Maria Fidela de Lima2012-04-27T11:44:30Zoai:revistas.usp.br:article/3135Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:44:30Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions Avaliação clínica de restaurações de lesões cervicais não cariosas |
title |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions |
spellingShingle |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions Santiago, Sérgio Lima Lesão cervical Resinas compostas Cimentos de ionômero de vidro Cervical lesion Composite resins Glass ionomer cements |
title_short |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions |
title_full |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions |
title_fullStr |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions |
title_full_unstemmed |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions |
title_sort |
One-year clinical evaluation of tooth-colored materials in non-carious cervical lesions |
author |
Santiago, Sérgio Lima |
author_facet |
Santiago, Sérgio Lima Franco, Eduardo Batista Mendonça, Juliano Sartori Lauris, José Roberto Pereira Navarro, Maria Fidela de Lima |
author_role |
author |
author2 |
Franco, Eduardo Batista Mendonça, Juliano Sartori Lauris, José Roberto Pereira Navarro, Maria Fidela de Lima |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Santiago, Sérgio Lima Franco, Eduardo Batista Mendonça, Juliano Sartori Lauris, José Roberto Pereira Navarro, Maria Fidela de Lima |
dc.subject.por.fl_str_mv |
Lesão cervical Resinas compostas Cimentos de ionômero de vidro Cervical lesion Composite resins Glass ionomer cements |
topic |
Lesão cervical Resinas compostas Cimentos de ionômero de vidro Cervical lesion Composite resins Glass ionomer cements |
description |
The purpose of this study was to assess the clinical performance of bonded composite (Excite/Tetric Ceram - Vivadent) versus a resin-modified glass ionomer cement (Vitremer - 3M) for restoring non-carious cervical lesions. A total of 70 restorations (thirty-five per material) were placed in 30 patients, 18-50 aged, by one operator. Rubber dam was employed in all cases, lesions were pumiced, enamel margins were not beveled, and no mechanical retention was placed. The restorations were directly assessed by two independent evaluators using modified-USPHS criteria for six clinical categories. The ratings for clinical acceptability restorations (alfa plus bravo) were as follows (Tetric Ceram/Vitremer): retention (86%/100%), marginal integrity (100%/100%), marginal discoloration (100%/100%), wear (97%/100%), postoperative sensitivity (100%/100%) and recurrent caries (100%/100%). Statistical analysis was completed with Fisher's exact or Pearson Chi-square tests at a significance level of 5% (P |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3135 10.1590/S1678-77572003000300004 |
url |
https://www.revistas.usp.br/jaos/article/view/3135 |
identifier_str_mv |
10.1590/S1678-77572003000300004 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3135/3824 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2003 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2003 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 11 No. 3 (2003); 175-180 Journal of Applied Oral Science; Vol. 11 Núm. 3 (2003); 175-180 Journal of Applied Oral Science; v. 11 n. 3 (2003); 175-180 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1800221671211139072 |