Effect of the disinfection technique on the linear dimensional stability of dental impression materials
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000300016 |
Resumo: | The purpose of this study was to evaluate the dimensional stability of heavy and light bodied condensation silicones after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Comfort and Xantopren VL Plus and the disinfectant solutions were 1% sodium hypochlorite and 2% glutaraldehyde. Impressions were made on a perforated stainless steel tray, according to the American Dental Association specification No. 19, adding up to a total of 50 samples. The double mixing method (one time, two viscosities) was used. Impressions were removed from the roulette block after 7 minutes to ensure complete curing and then immersed in the solutions. Impressions not submitted to treatment composed the control group. After these steps, the impressions were removed from the solution, rinsed in running water and air-dried. Three-dimensional measurements were calculated using an optic microscope graduated at 0.001 mm. The two-way ANOVA indicated no differences (p>0.05) for any combination between variables. The results showed that the solution studied can be safely used to disinfect condensation silicone in clinical prosthodontic procedures. |
id |
USP-17_dfa7af442a619e8b7ede2bdd37ab5c78 |
---|---|
oai_identifier_str |
oai:scielo:S1678-77572004000300016 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Effect of the disinfection technique on the linear dimensional stability of dental impression materialsDental impression materialsSilicone elastomersDisinfectionDimensional stabilityThe purpose of this study was to evaluate the dimensional stability of heavy and light bodied condensation silicones after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Comfort and Xantopren VL Plus and the disinfectant solutions were 1% sodium hypochlorite and 2% glutaraldehyde. Impressions were made on a perforated stainless steel tray, according to the American Dental Association specification No. 19, adding up to a total of 50 samples. The double mixing method (one time, two viscosities) was used. Impressions were removed from the roulette block after 7 minutes to ensure complete curing and then immersed in the solutions. Impressions not submitted to treatment composed the control group. After these steps, the impressions were removed from the solution, rinsed in running water and air-dried. Three-dimensional measurements were calculated using an optic microscope graduated at 0.001 mm. The two-way ANOVA indicated no differences (p>0.05) for any combination between variables. The results showed that the solution studied can be safely used to disinfect condensation silicone in clinical prosthodontic procedures.Faculdade De Odontologia De Bauru - USP2004-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000300016Journal of Applied Oral Science v.12 n.3 2004reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572004000300016info:eu-repo/semantics/openAccessSilva,Sávio Marcelo Leite Moreira daSalvador,Milton Carlos Gonçalveseng2004-10-05T00:00:00Zoai:scielo:S1678-77572004000300016Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2004-10-05T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Effect of the disinfection technique on the linear dimensional stability of dental impression materials |
title |
Effect of the disinfection technique on the linear dimensional stability of dental impression materials |
spellingShingle |
Effect of the disinfection technique on the linear dimensional stability of dental impression materials Silva,Sávio Marcelo Leite Moreira da Dental impression materials Silicone elastomers Disinfection Dimensional stability |
title_short |
Effect of the disinfection technique on the linear dimensional stability of dental impression materials |
title_full |
Effect of the disinfection technique on the linear dimensional stability of dental impression materials |
title_fullStr |
Effect of the disinfection technique on the linear dimensional stability of dental impression materials |
title_full_unstemmed |
Effect of the disinfection technique on the linear dimensional stability of dental impression materials |
title_sort |
Effect of the disinfection technique on the linear dimensional stability of dental impression materials |
author |
Silva,Sávio Marcelo Leite Moreira da |
author_facet |
Silva,Sávio Marcelo Leite Moreira da Salvador,Milton Carlos Gonçalves |
author_role |
author |
author2 |
Salvador,Milton Carlos Gonçalves |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Silva,Sávio Marcelo Leite Moreira da Salvador,Milton Carlos Gonçalves |
dc.subject.por.fl_str_mv |
Dental impression materials Silicone elastomers Disinfection Dimensional stability |
topic |
Dental impression materials Silicone elastomers Disinfection Dimensional stability |
description |
The purpose of this study was to evaluate the dimensional stability of heavy and light bodied condensation silicones after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Comfort and Xantopren VL Plus and the disinfectant solutions were 1% sodium hypochlorite and 2% glutaraldehyde. Impressions were made on a perforated stainless steel tray, according to the American Dental Association specification No. 19, adding up to a total of 50 samples. The double mixing method (one time, two viscosities) was used. Impressions were removed from the roulette block after 7 minutes to ensure complete curing and then immersed in the solutions. Impressions not submitted to treatment composed the control group. After these steps, the impressions were removed from the solution, rinsed in running water and air-dried. Three-dimensional measurements were calculated using an optic microscope graduated at 0.001 mm. The two-way ANOVA indicated no differences (p>0.05) for any combination between variables. The results showed that the solution studied can be safely used to disinfect condensation silicone in clinical prosthodontic procedures. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000300016 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000300016 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1678-77572004000300016 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science v.12 n.3 2004 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1748936433527160832 |